Energy balance in Suzhou
| Moderator:nobody (see all) |
| This page is a stub. You may improve it into a full page. |
| Upload data
|
Question
What are the amounts of energy produced, consumed, imported, and exported in Suzhou?
Answer
Rationale
There are several energy transformations that each describe a specific process of energy production or use. Per unit activity, there is a constant amount of different inputs and outputs into and from this process, respectively. These unit processes are used for Suzhou in such a way that one critical input or output from each relevant energy transformation is listed here; all other inputs and outputs logically follow from the nature of the transformation process.
Data
| Obs | Year | Equation | Dummy | Description |
|---|---|---|---|---|
| 1 | 2010 | TP raw coal + TP natural gas + TP oil products + TP coal products + TP other energy + TP heat = TP electricity + TP loss | 1 | In energy balance, inputs and outputs cancel out. Balance Thermal Power Plants. 17194.0 + 670.9 + 21.4 + 1145.5 + 198.0 + 54.7 = 7460.4 + 11824.1, respectively (GWh /a?). |
| 2 | 2010 | TP natural gas = 0.039019425*TP raw coal | 1 | Fraction from TP raw coal. |
| 3 | 2010 | TP oil products = 0.001244620*TP raw coal | 1 | Fraction from TP raw coal. |
| 4 | 2010 | TP coal products = 0.066622077*TP raw coal | 1 | Fraction from TP raw coal. |
| 5 | 2010 | TP other energy = 0.011515645*TP raw coal | 1 | Fraction from TP raw coal. |
| 6 | 2010 | TP heat = 0.003181342*TP raw coal | 1 | Fraction from TP raw coal. |
| 7 | 2010 | TP electricity = 0.630948656*TP loss | 1 | Fraction from TP loss. |
| 8 | 2010 | H raw coal + H natural gas + H oil products + H coal products + H other energy = H heat + H loss | -1 | Balance Heating Supply. In energy balance, inputs and outputs cancle out |
| 9 | 2010 | H natural gas + H oil products + H coal products + H other energy = 0.158111641*H raw coal | -1 | (88,0+38,6+360,3+27,2)/3251,5 Others divided by raw coal. Fraction H raw coal. Sum of other fuels is used as comparison for raw coal |
| 10 | 2010 | H raw coal + H oil products + H coal products + H other energy = 41.79090909*H natural gas | -1 | (3251,5+38,6+360,3+27,2)/88,0 Others divided by natural gas. Fraction H natural gas. Sum of other fuels is used as comparison for natural gas |
| 11 | 2010 | H raw coal + H natural gas + H coal products + H other energy = 96.55440415*H oil products | -1 | (3251,5+88,0+360,3+27,2)/38,6 Others divided by oil products. Sum of other fuels is used as comparison for oil products. Fraction H oil products |
| 12 | 2010 | H raw coal + H natural gas + H oil products + H other energy = 9.451290591*H coal products | -1 | (3251,5+88,0+38,6+27,2)/360,3 Others divided by coal products. Fraction H coal products. Sum of other fuels is used as comparison for coal products |
| 13 | 2010 | H heat = 4.451715651*H loss | -1 | 3074,8/690,7 heat per loss. Fraction H loss. Amount of heat is used as comparison for loss |
| 14 | 2010 | CP raw coal + CP natural gas + CP oil products = CP coal products + CP loss | 1 | Balance Coal Processing. In energy balance, inputs and outputs cancel out |
| 15 | 2010 | CP natural gas + CP oil products = 0.004725972*CP raw coal | -1 | (0,007+0,0172)/5,12064 Others divided by raw coal. Fraction CP raw coal. Sum of other fuels is used as comparison for raw coal |
| 16 | 2010 | CP oil products = 24.57142857*CP natural gas | 1 | 0,01720/0,0007 oil products divided by natural gas. Fraction CP natural gas. Amount of oil products is used as comparison for natural gas |
| 17 | 2010 | CP coal products = 6.341763109*CP loss | 1 | 4,4386/0,6999 coal products per loss. Fraction CP loss. Amount of coal products is used as comparison for loss |
| 18 | 2010 | Loss heat = 0.029823078*H heat | 1 | 91,7/3074,8. Transmission loss heat. Known loss divided by production |
| 19 | 2010 | Loss oil products = 0.953271028*TP oil products | 1 | 20,4/21,4. Transmission loss oil products. Known loss divided by oil products used in TP |
| 20 | 2010 | Loss electricity = 0.085276929*TP electricity | 1 | 636,2/7460,4. Transmission loss electricity. Known loss divided by production |
| 21 | 2010 | Loss natural gas = 0.3625*H natural gas | 1 | 31,9/88,0. Transmission loss natural gas. Known loss divided by natural gas used in H |
| 22 | 2010 | Bought electricity + TP electricity = Loss electricity + Cons Agri electricity + Cons Ind electricity + Cons Transportation electricity + Cons Commerce electricity + Cons Households electricity | 1 | Electricity use balance. In energy balance, inputs and outputs cancel out |
| 23 | 2010 | H heat = Loss heat + Cons Ind heat + Cons Commerce heat | 1 | Heat use balance. In energy balance, inputs and outputs cancel out |
| 24 | 2010 | Cons Agri electricity = 25.8468532 | 1 | Consumed electricity agriculture |
| 25 | 2010 | Cons Ind electricity = 7032.044935 | 1 | Consumed electricity industry |
| 26 | 2010 | Cons Transportation electricity = 49.8664292 | 1 | Consumed electricity transportation |
| 27 | 2010 | Cons Commerce electricity = 684.7050273 | 1 | Consumed electricity commerce |
| 28 | 2010 | Cons Households electricity = 625.3804599 | 1 | Consumed electricity households |
| 29 | 2010 | Cons Ind heat = 2981.313692 | 1 | Consumed heat industry |
| 30 | 2010 | Cons Commerce heat = 1.732034769 | 1 | Consumed heat commerce |
| 31 | 2010 | TP electricity = 7460.4 | 1 | Electricity produced by thermal power. Assumes that there is no capacity to increase production. |
| 32 | 2010 | CP coal products = 4.4386 | 1 | Coal products produced |
| 33 | 2020 | TP raw coal + TP natural gas + TP oil products + TP coal products + TP other energy + TP heat = TP electricity + TP loss | 1 | In energy balance, inputs and outputs cancel out. Balance Thermal Power Plants. |
| 34 | 2020 | TP natural gas = 0.0390180013341954*TP raw coal | 1 | Fraction from TP raw coal. |
| 35 | 2020 | TP oil products = 0.00124415516846148*TP raw coal | 1 | Fraction from TP raw coal. |
| 36 | 2020 | TP coal products = 0.0666203905225772*TP raw coal | 1 | Fraction from TP raw coal. |
| 37 | 2020 | TP other energy = 0.0115132299117319*TP raw coal | 1 | Fraction from TP raw coal. |
| 38 | 2020 | TP heat = 0.00318231341226894*TP raw coal | 1 | Fraction from TP raw coal. |
| 39 | 2020 | TP electricity = 0.630946878757119*TP loss | 1 | Fraction from TP loss. |
| 40 | 2020 | H raw coal + H natural gas + H oil products + H coal products + H other energy = H heat + H loss | -1 | Balance Heating Supply. In energy balance, inputs and outputs cancle out |
| 41 | 2020 | H natural gas + H oil products + H coal products + H other energy = 0.158087304841969*H raw coal | -1 | Others divided by raw coal. Fraction H raw coal. Sum of other fuels is used as comparison for raw coal |
| 42 | 2020 | H raw coal + H oil products + H coal products + H other energy = 41.7716151890517*H natural gas | -1 | Others divided by natural gas. Fraction H natural gas. Sum of other fuels is used as comparison for natural gas |
| 43 | 2020 | H raw coal + H natural gas + H coal products + H other energy = 96.6515588433253*H oil products | -1 | Others divided by oil products. Sum of other fuels is used as comparison for oil products. Fraction H oil products |
| 44 | 2020 | H raw coal + H natural gas + H oil products + H other energy = 9.45240021414551*H coal products | -1 | Others divided by coal products. Fraction H coal products. Sum of other fuels is used as comparison for coal products |
| 45 | 2020 | H heat = 4.45146745537653*H loss | -1 | heat per loss. Fraction H loss. Amount of heat is used as comparison for loss |
| 46 | 2020 | CP raw coal + CP natural gas + CP oil products = CP coal products + CP loss | 1 | Balance Coal Processing. In energy balance, inputs and outputs cancel out |
| 47 | 2020 | CP natural gas + CP oil products = 0.00349890225051744*CP raw coal | -1 | Others divided by raw coal. Fraction CP raw coal. Sum of other fuels is used as comparison for raw coal |
| 48 | 2020 | CP oil products = 24.1033082706767*CP natural gas | 1 | oil products divided by natural gas. Fraction CP natural gas. Amount of oil products is used as comparison for natural gas |
| 49 | 2020 | CP coal products = 6.34159395844515*CP loss | 1 | coal products per loss. Fraction CP loss. Amount of coal products is used as comparison for loss |
| 50 | 2020 | Loss heat = 0.0298263751792101*H heat | 1 | Transmission loss heat. Known loss divided by production |
| 51 | 2020 | Loss oil products = 0.833579527132038*TP oil products | 1 | Transmission loss oil products. Known loss divided by oil products used in TP |
| 52 | 2020 | Loss electricity = 0.0852839003677908*TP electricity | 1 | Transmission loss electricity. Known loss divided by production |
| 53 | 2020 | Loss natural gas = 0.414682168778854*H natural gas | 1 | Transmission loss natural gas. Known loss divided by natural gas used in H |
| 54 | 2020 | Bought electricity + TP electricity = Loss electricity + Cons Agri electricity + Cons Ind electricity + Cons Transportation electricity + Cons Commerce electricity + Cons Households electricity | 1 | Electricity use balance. In energy balance, inputs and outputs cancel out |
| 55 | 2020 | H heat = Loss heat + Cons Ind heat + Cons Commerce heat | 1 | Heat use balance. In energy balance, inputs and outputs cancel out |
| 56 | 2020 | Cons Agri electricity = 29.72388118 | 1 | Consumed electricity agriculture |
| 57 | 2020 | Cons Ind electricity = 9844.8629091652 | 1 | Consumed electricity industry |
| 58 | 2020 | Cons Transportation electricity = 89.75957256 | 1 | Consumed electricity transportation |
| 59 | 2020 | Cons Commerce electricity = 787.410781395 | 1 | Consumed electricity commerce |
| 60 | 2020 | Cons Households electricity = 719.187528885 | 1 | Consumed electricity households |
| 61 | 2020 | Cons Ind heat = 4173.83916836834 | 1 | Consumed heat industry |
| 62 | 2020 | Cons Commerce heat = 1.991839984065 | 1 | Consumed heat commerce |
| 63 | 2020 | TP electricity = 11936.5867936 | 1 | Electricity produced by thermal power. Assumes that there is no capacity to increase production. |
| 64 | 2020 | CP coal products = 6.21409115526259 | 1 | Coal products produced |
There are no nonlinearities.
Dependencies
Calculations
- See Energy balance.
- Model version used to run results for ISEE2013. Model run 18 Aug 2013
- Previous model version
- Model run from a previous version (there is a problem with data).
See also
Keywords
References