Energy balance in Basel

From Opasnet
Revision as of 14:40, 6 June 2014 by Teemu R (talk | contribs) (→‎Calculations: new plot)
Jump to navigation Jump to search



Question

What are the amounts of energy produced, consumed, imported, and exported in Basel?

Answer

Rationale

There are several energy transformations that each describe a specific process of energy production or use. Per unit activity, there is a constant amount of different inputs and outputs into and from this process, respectively. These unit processes are used for Suzhou in such a way that one critical input or output from each relevant energy transformation is listed here; all other inputs and outputs logically follow from the nature of the transformation process.

Data

Equations(TJ)
ObsYearEquationDummy
12010H_other_in + H_oil_in + H_gas_in + H_electricity_in + H_environment_in = H_electricity_out + H_heat_out + H_loss0
22010H_other_in + H_gas_in + H_electricity_in + H_environment_in = 18.759336099585 * H_oil_in0
32010H_other_in + H_oil_in + H_electricity_in + H_environment_in = 1.00505263157895 * H_gas_in0
42010H_other_in + H_oil_in + H_gas_in + H_environment_in = 94.2399999999989 * H_electricity_in0
52010H_other_in + H_oil_in + H_gas_in + H_electricity_in = 92.3725490196079 * H_environment_in0
62010H_heat_out = 4.04461371055495 * H_loss0
72010H_electricity_out = 0.137105549510337 * H_loss0
82010Loss_electricity = 10.6690825426753 * H_electricity_out0
92010Loss_oil = 0.0445888958928925 * H_oil_in0
102010Loss_gas = 0.00967082506829371 * H_gas_in0
112010Loss_heat = 0.142050040355125 * H_heat_out0
122010Import_electricity + H_electricity_out + Recovery_electricity = Loss_electricity + Household_electricity + Industry_electricity + Commerce_electricity + Transport_electricity0
132010Recovery_heat + H_heat_out = Loss_heat + Household_heat + Industry_heat + Commerce_heat0
142010Household_electricity = 1344.10958904110
152010Industry_electricity = 1341.964285714290
162010Commerce_electricity = 2940.971428571430
172010Transport_electricity = 2600
182010Household_heat = 9320
192010Industry_heat = 3330
202010Commerce_heat = 16330
212010H_heat_out = 3175.009002029180
222010Recovery_electricity = 50.9655865482360
232020H_other_in + H_oil_in + H_gas_in + H_electricity_in + H_environment_in = H_electricity_out + H_heat_out + H_loss0
242020H_other_in + H_gas_in + H_electricity_in + H_environment_in = 18.7593360995851 * H_oil_in0
252020H_other_in + H_oil_in + H_electricity_in + H_environment_in = 1.00505263157895 * H_gas_in0
262020H_other_in + H_oil_in + H_gas_in + H_environment_in = 94.24 * H_electricity_in0
272020H_other_in + H_oil_in + H_gas_in + H_electricity_in = 92.3725490196077 * H_environment_in0
282020H_heat_out = 4.04461371055495 * H_loss0
292020H_electricity_out = 0.137105549510337 * H_loss0
302020Loss_electricity = 11.5997703806749 * H_electricity_out0
312020Loss_oil = 0.0346903754680064 * H_oil_in0
322020Loss_gas = 0.0052086734616975 * H_gas_in0
332020Loss_heat = 0.142050040355125 * H_heat_out0
342020Import_electricity + H_electricity_out + Recovery_electricity = Loss_electricity + Household_electricity + Industry_electricity + Commerce_electricity + Transport_electricity0
352020Recovery_heat + H_heat_out = Loss_heat + Household_heat + Industry_heat + Commerce_heat0
362020Household_electricity = 2037.586130136990
372020Industry_electricity = 2515.17656250
382020Commerce_electricity = 3505.320
392020Transport_electricity = 286.650
402020Household_heat = 1541.2950
412020Industry_heat = 367.13250
422020Commerce_heat = 1800.38250
432020H_heat_out = 4139.402858681650
442020Recovery_electricity = 72.242385501630

There are no nonlinearities.

Dependencies

Calculations

+ Show code

See also

Urgenche research project 2011 - 2014: city-level climate change mitigation
Urgenche pages

Urgenche main page · Category:Urgenche · Urgenche project page (password-protected)

Relevant data
Building stock data in Urgenche‎ · Building regulations in Finland · Concentration-response to PM2.5 · Emission factors for burning processes · ERF of indoor dampness on respiratory health effects · ERF of several environmental pollutions · General criteria for land use · Indoor environment quality (IEQ) factors · Intake fractions of PM · Land use in Urgenche · Land use and boundary in Urgenche · Energy use of buildings

Relevant methods
Building model · Energy balance · Health impact assessment · Opasnet map · Help:Drawing graphs · OpasnetUtils‎ · Recommended R functions‎ · Using summary tables‎

City Kuopio
Climate change policies and health in Kuopio (assessment) · Climate change policies in Kuopio (plausible city-level climate policies) · Health impacts of energy consumption in Kuopio · Building stock in Kuopio · Cost curves for energy (prioritization of options) · Energy balance in Kuopio (energy data) · Energy consumption and GHG emissions in Kuopio by sector · Energy consumption classes (categorisation) · Energy consumption of heating of buildings in Kuopio · Energy transformations (energy production and use processes) · Fuels used by Haapaniemi energy plant · Greenhouse gas emissions in Kuopio · Haapaniemi energy plant in Kuopio · Land use in Kuopio · Building data availability in Kuopio · Password-protected pages: File:Heat use in Kuopio.csv · Kuopio housing

City Basel
Buildings in Basel (password-protected)

Energy balances
Energy balance in Basel · Energy balance in Kuopio · Energy balance in Stuttgart · Energy balance in Suzhou


Keywords

References


Related files