<t2b name="Equations" index="Equation" obs="Dummy" desc="Description" unit="GWh /a?">
<t2b name="Equations" index="Year,Equation" obs="Dummy" desc="Description" unit="GWh /a?">
STP renewable energy + STP electricity = STP local heating|1|Balance Solar Thermal Pump. In energy balance, inputs and outputs cancel out
2008|STP renewable energy + STP electricity = STP local heating|1|Balance Solar Thermal Pump. In energy balance, inputs and outputs cancel out
STP electricity = 0.363636364*STP renewable energy|1|Fraction STP renewable energy. Amount of electricity is used as comparison for renewable energy. 8/22 Electricity divided by renewable energy
2008|STP electricity = 0.363636364*STP renewable energy|1|Fraction STP renewable energy. Amount of electricity is used as comparison for renewable energy. 8/22 Electricity divided by renewable energy
CHP gas + CHP renewable energy + CHP mineral oil = CHP local heating + CHP electricity + CHP loss|1|Balance CHP Plants. In energy balance, inputs and outputs cancel out
2008|CHP gas + CHP renewable energy + CHP mineral oil = CHP local heating + CHP electricity + CHP loss|1|Balance CHP Plants. In energy balance, inputs and outputs cancel out
CHP renewable energy + CHP mineral oil = 0.564814815*CHP gas|1|Fraction CHP gas. Sum of other fuels is used as comparison for gas. (108+14)/216 Others divided by gas
2008|CHP renewable energy + CHP mineral oil = 0.564814815*CHP gas|1|Fraction CHP gas. Sum of other fuels is used as comparison for gas. (108+14)/216 Others divided by gas
CHP gas + CHP mineral oil = 2.12962963*CHP renewable energy|1|Sum of other fuels is used as comparison for renewable energy. Fraction CHP renewable energy. (216+14)/108 Others divided by renewable energy
2008|CHP gas + CHP mineral oil = 2.12962963*CHP renewable energy|1|Sum of other fuels is used as comparison for renewable energy. Fraction CHP renewable energy. (216+14)/108 Others divided by renewable energy
CHP electricity + CHP loss = 1.770491803*CHP local heating|1|Fraction CHP local heating. Sum of other outputs is used as comparison for local heating. (84+132)/122 Others divided by local heating.
2008|CHP electricity + CHP loss = 1.770491803*CHP local heating|1|Fraction CHP local heating. Sum of other outputs is used as comparison for local heating. (84+132)/122 Others divided by local heating.
CHP local heating + CHP loss = 3.023809524*CHP electricity|1|Fraction CHP electricity. Sum of other outputs is used as comparison for electricity. (122+132)/84 Others divided by electricity
2008|CHP local heating + CHP loss = 3.023809524*CHP electricity|1|Fraction CHP electricity. Sum of other outputs is used as comparison for electricity. (122+132)/84 Others divided by electricity
WWP renewable energy = WWP electricity|1|Balance Water, Wind, Photovlotaics. In energy balance, inputs and outputs cancel out
2008|WWP renewable energy = WWP electricity|1|Balance Water, Wind, Photovlotaics. In energy balance, inputs and outputs cancel out
TPP electricity input + TPP mineral oil + TPP gas = TPP local heating + TPP electricity output + TPP loss|1|Balance Thermal Power Plant Pfaffenwald. In energy balance, inputs and outputs cancel out
2008|TPP electricity input + TPP mineral oil + TPP gas = TPP local heating + TPP electricity output + TPP loss|1|Balance Thermal Power Plant Pfaffenwald. In energy balance, inputs and outputs cancel out
TPP mineral oil + TPP gas = 23.33333333*TPP electricity input|1|Fraction TPP electricity input. Sum of other fuels is used as comparison for electricity input. (43+167)/9 Others divided by electricity input
2008|TPP mineral oil + TPP gas = 23.33333333*TPP electricity input|1|Fraction TPP electricity input. Sum of other fuels is used as comparison for electricity input. (43+167)/9 Others divided by electricity input
TPP electricity input + TPP gas = 4.093023256*TPP mineral oil|1|Fraction TPP mineral oil. Sum of other fuels is used as comparison for mineral oil. (9+167)/43 Others divided by mineral oil
2008|TPP electricity input + TPP gas = 4.093023256*TPP mineral oil|1|Fraction TPP mineral oil. Sum of other fuels is used as comparison for mineral oil. (9+167)/43 Others divided by mineral oil
TPP electricity output + TPP loss = 0.335365854*TPP local heating|1|Fraction TPP local heating. Sum of other outputs is used as comparison for local heating. (50+5)/164 Others divided by local heating
2008|TPP electricity output + TPP loss = 0.335365854*TPP local heating|1|Fraction TPP local heating. Sum of other outputs is used as comparison for local heating. (50+5)/164 Others divided by local heating
TPP local heating +TPP loss = 3.38*TPP electricity output|1|Fraction TPP electricity output. Sum of other outputs is used as comparison for electricity. (164+5)/50 Others divided by electricity
2008|TPP local heating +TPP loss = 3.38*TPP electricity output|1|Fraction TPP electricity output. Sum of other outputs is used as comparison for electricity. (164+5)/50 Others divided by electricity
TPE waste + TPE gas + TPE coal + TPE mineral oil = TPE electricity + TPE district heating + TPE loss|1|Balance Thermal Power Plant EVU. In energy balance, inputs and outputs cancel out
2008|TPE waste + TPE gas + TPE coal + TPE mineral oil = TPE electricity + TPE district heating + TPE loss|1|Balance Thermal Power Plant EVU. In energy balance, inputs and outputs cancel out
TPE gas + TPE coal + TPE mineral oil = 1.04973357*TPE waste|1|Fraction TPE waste. Sum of other fuels is used as comparison for waste. (162+1019+1)/1126 Others divided by waste
2008|TPE gas + TPE coal + TPE mineral oil = 1.04973357*TPE waste|1|Fraction TPE waste. Sum of other fuels is used as comparison for waste. (162+1019+1)/1126 Others divided by waste
TPE waste + TPE coal + TPE mineral oil = 13.24691358*TPE gas|1|Fraction TPE gas. Sum of other fuels is used as comparison for gas. (1126+1019+1)/162 Others divided by gas
2008|TPE waste + TPE coal + TPE mineral oil = 13.24691358*TPE gas|1|Fraction TPE gas. Sum of other fuels is used as comparison for gas. (1126+1019+1)/162 Others divided by gas
TPE waste + TPE gas + TPE mineral oil = 1.264965653*TPE coal|1|Fraction TPE coal. Sum of other fuels is used as comparison for coal. (1126+162+1)/1019  Others divided by coal
2008|TPE waste + TPE gas + TPE mineral oil = 1.264965653*TPE coal|1|Fraction TPE coal. Sum of other fuels is used as comparison for coal. (1126+162+1)/1019  Others divided by coal
TPE district heating + TPE loss = 5.089709763*TPE electricity|1|Fraction TPE electricity. Sum of other outputs is used as comparison for electricity. (1101+828)/379 Others divided by electricity
2008|TPE district heating + TPE loss = 5.089709763*TPE electricity|1|Fraction TPE electricity. Sum of other outputs is used as comparison for electricity. (1101+828)/379 Others divided by electricity
TPE electricity + TPE loss = 1.096276113*TPE district heating|1|Fraction TPE district heating. Sum of other outputs is used as comparison for district heating. (379 +828)/1101 Others divided by district heating
2008|TPE electricity + TPE loss = 1.096276113*TPE district heating|1|Fraction TPE district heating. Sum of other outputs is used as comparison for district heating. (379 +828)/1101 Others divided by district heating
Ind gas = Ind electricity + Ind loss|1|Balance Industrial Plants. In energy balance, inputs and outputs cancel out
2008|Ind gas = Ind electricity + Ind loss|1|Balance Industrial Plants. In energy balance, inputs and outputs cancel out
Ind electricity = 0.533333333*Ind loss|1|Fraction Ind loss. Amount of district heating is used as comparison for loss. 8/15 district heating per loss
2008|Ind electricity = 0.533333333*Ind loss|1|Fraction Ind loss. Amount of district heating is used as comparison for loss. 8/15 district heating per loss
STP local heating = 0.245901639*CHP local heating|1|Fraction local heating producers. CHP local heating production is used as reference. 30/122 STP local heating divided by CHP local heating
2008|STP local heating = 0.245901639*CHP local heating|1|Fraction local heating producers. CHP local heating production is used as reference. 30/122 STP local heating divided by CHP local heating
Ind electricity = 0.007266122*CHP electricity|1|Fraction electricity producers 1. 8/1101 Ind electricity divided by TPE district heating CORRECTED
2008|Ind electricity = 0.007266122*CHP electricity|1|Fraction electricity producers 1. 8/1101 Ind electricity divided by TPE district heating CORRECTED
WWP electricity = 0.797619048*CHP electricity|1|Fraction electricity producers 2. CHP electricity production is used as reference. 67/84 WWP electricity divided by CHP electricity
2008|WWP electricity = 0.797619048*CHP electricity|1|Fraction electricity producers 2. CHP electricity production is used as reference. 67/84 WWP electricity divided by CHP electricity
TPP electricity output = 0.595238095*CHP electricity|1|Fraction electricity producers 3. CHP electricity production is used as reference. 50/84 TPP electricity divided by CHP electricity
2008|TPP electricity output = 0.595238095*CHP electricity|1|Fraction electricity producers 3. CHP electricity production is used as reference. 50/84 TPP electricity divided by CHP electricity
TPE electricity = 4.511904762*CHP electricity|1|Fraction electricity producers 4. CHP electricity production is used as reference. 379/84 TPE electricity divided by CHP electricity
2008|TPE electricity = 4.511904762*CHP electricity|1|Fraction electricity producers 4. CHP electricity production is used as reference. 379/84 TPE electricity divided by CHP electricity
Loss local heating = 0.041139241*STP local heating + 0.041139241*CHP local heating + 0.041139241*TPP local heating|1|Transmission loss local heating. Known loss divided by production. 13/(30+122+164)
2008|Loss local heating = 0.041139241*STP local heating + 0.041139241*CHP local heating + 0.041139241*TPP local heating|1|Transmission loss local heating. Known loss divided by production. 13/(30+122+164)
Loss electricity = 0.221088435*CHP electricity + 0.221088435*WWP electricity + 0.221088435*TPP electricity output + 0.221088435*TPE electricity + 0.221088435*Ind electricity|1|Transmission loss electricity. Known loss divided by production. 130/(84+67+50+379+8)
2008|Loss electricity = 0.221088435*CHP electricity + 0.221088435*WWP electricity + 0.221088435*TPP electricity output + 0.221088435*TPE electricity + 0.221088435*Ind electricity|1|Transmission loss electricity. Known loss divided by production. 130/(84+67+50+379+8)
Loss district heating = 0.109900091*TPE district heating|1|Transmission loss district heating. Known loss divided by production. 121/1101
2008|Loss district heating = 0.109900091*TPE district heating|1|Transmission loss district heating. Known loss divided by production. 121/1101
CES local heating = 0.366666667*STP local heating|1|Consumption in the Energy Sector local heating. STP local heating is used as reference. 11/30
2008|CES local heating = 0.366666667*STP local heating|1|Consumption in the Energy Sector local heating. STP local heating is used as reference. 11/30
CES electricity = 1.392857143*CHP electricity|1|Consumption in the Energy Sector electricity. CHP electricity is used as reference. 117/84
2008|CES electricity = 1.392857143*CHP electricity|1|Consumption in the Energy Sector electricity. CHP electricity is used as reference. 117/84
V renewable energy = 0.272727273*STP renewable energy|1|Vorketten renewable energy. STP renewable energy is used as reference. 6/22
2008|V renewable energy = 0.272727273*STP renewable energy|1|Vorketten renewable energy. STP renewable energy is used as reference. 6/22
V coal = 0.103042198*TPE coal|1|Vorketten coal. TPE coal is used as reference. 105/1019
2008|V coal = 0.103042198*TPE coal|1|Vorketten coal. TPE coal is used as reference. 105/1019
V electricity = 17.79683377*TPE electricity|1|Vorketten electricity. TPE electricity is used as reference. 6745/379
2008|V electricity = 17.79683377*TPE electricity|1|Vorketten electricity. TPE electricity is used as reference. 6745/379
V gas = 2.027777778*CHP gas|1|Vorketten gas. CHP gas is used as reference. 438/216
2008|V gas = 2.027777778*CHP gas|1|Vorketten gas. CHP gas is used as reference. 438/216
V mineral oil = 12.3255814*TPP mineral oil|1|Vorketten mineral oil. TPP mineral oil is used as reference. 530/43
2008|V mineral oil = 12.3255814*TPP mineral oil|1|Vorketten mineral oil. TPP mineral oil is used as reference. 530/43
Bought electricity + CHP electricity + WWP electricity + TPP electricity output + TPE electricity + Ind electricity = STP electricity + TPP electricity input + Loss electricity + CES electricity + V electricity + Cons Ind electricity + Cons Traffic electricity + Cons Home electricity + Cons Commerce electricity|1|Electricity use balance. In energy balance, inputs and outputs cancel out
2008|Bought electricity + CHP electricity + WWP electricity + TPP electricity output + TPE electricity + Ind electricity = STP electricity + TPP electricity input + Loss electricity + CES electricity + V electricity + Cons Ind electricity + Cons Traffic electricity + Cons Home electricity + Cons Commerce electricity|1|Electricity use balance. In energy balance, inputs and outputs cancel out
STP local heating + CHP local heating + TPP local heating = Loss local heating + CES local heating + Cons Ind local heating + Cons Home local heating + Cons Commerce local heating|1|Local heating balance. In energy balance, inputs and outputs cancel out
2008|STP local heating + CHP local heating + TPP local heating = Loss local heating + CES local heating + Cons Ind local heating + Cons Home local heating + Cons Commerce local heating|1|Local heating balance. In energy balance, inputs and outputs cancel out
Bought district heating + TPE district heating = Loss district heating + Cons Ind district heating + Cons Home district heating + Cons Commerce district heating|1|District heating balance. In energy balance, inputs and outputs cancel out
2008|Bought district heating + TPE district heating = Loss district heating + Cons Ind district heating + Cons Home district heating + Cons Commerce district heating|1|District heating balance. In energy balance, inputs and outputs cancel out
Cons Ind electricity = 2257|1|Consumed electricity industry
2008|Cons Ind electricity = 2257|1|Consumed electricity industry
Cons Traffic electricity = 224|1|Consumed electricity traffic
2008|Cons Traffic electricity = 224|1|Consumed electricity traffic
Cons Home electricity = 1077|1|Consumed electricity households
2008|Cons Home electricity = 1077|1|Consumed electricity households
Cons Commerce electricity = 695|1|Consumed electricity commerce
2008|Cons Commerce electricity = 695|1|Consumed electricity commerce
Cons Ind local heating = 35|1|Consumed local heating industry
2008|Cons Ind local heating = 35|1|Consumed local heating industry
Cons Home local heating = 54|1|Consumed local heating households
2008|Cons Home local heating = 54|1|Consumed local heating households
Cons Commerce local heating = 203|1|Consumed local heating commerce
2008|Cons Commerce local heating = 203|1|Consumed local heating commerce
Cons Ind district heating = 513|1|Consumed districit heating industry
2008|Cons Ind district heating = 513|1|Consumed districit heating industry
Cons Home district heating = 35|1|Consumed districit heating households
2008|Cons Home district heating = 35|1|Consumed districit heating households
Cons Commerce district heating = 851|1|Consumed districit heating commerce
2008|Cons Commerce district heating = 851|1|Consumed districit heating commerce
2010|STP renewable energy + STP electricity = STP local heating|1|Balance Solar Thermal Pump. In energy balance, inputs and outputs cancel out
2010|STP electricity = 0.352941176*STP renewable energy|1|Fraction STP renewable energy. Amount of electricity is used as comparison for renewable energy. 12/34 Electricity divided by renewable energy
2010|CHP gas + CHP renewable energy + CHP mineral oil = CHP local heating + CHP electricity + CHP loss|1|Balance CHP Plants. In energy balance, inputs and outputs cancel out
2010|CHP renewable energy + CHP mineral oil = 3.848484848*CHP gas|1|Fraction CHP gas. Sum of other fuels is used as comparison for gas. (116+11)/33 Others divided by gas
2010|CHP gas + CHP mineral oil = 0.379310344*CHP renewable energy|1|Sum of other fuels is used as comparison for renewable energy. Fraction CHP renewable energy. (33+11)/116 Others divided by renewable energy
2010|CHP electricity + CHP loss = 3.324324324*CHP local heating|1|Fraction CHP local heating. Sum of other outputs is used as comparison for local heating. (27+96)/37 Others divided by local heating.
2010|CHP local heating + CHP loss = 4.925925925*CHP electricity|1|Fraction CHP electricity. Sum of other outputs is used as comparison for electricity. (37+96)/27 Others divided by electricity
2010|WWP renewable energy = WWP electricity|1|Balance Water, Wind, Photovlotaics. In energy balance, inputs and outputs cancel out
2010|TPP electricity input + TPP mineral oil + TPP gas = TPP local heating + TPP electricity output + TPP loss|1|Balance Thermal Power Plant Pfaffenwald. In energy balance, inputs and outputs cancel out
2010|TPP mineral oil + TPP gas = 26*TPP electricity input|1|Fraction TPP electricity input. Sum of other fuels is used as comparison for electricity input. (17+217)/9 Others divided by electricity input
2010|TPP electricity input + TPP gas = 13.294117647*TPP mineral oil|1|Fraction TPP mineral oil. Sum of other fuels is used as comparison for mineral oil. (9+217)/17 Others divided by mineral oil
2010|TPP electricity output + TPP loss = 0.380681818*TPP local heating|1|Fraction TPP local heating. Sum of other outputs is used as comparison for local heating. (61+6)/176 Others divided by local heating
2010|TPP local heating +TPP loss = 2.983606557*TPP electricity output|1|Fraction TPP electricity output. Sum of other outputs is used as comparison for electricity. (176+6)/61 Others divided by electricity
2010|TPE waste + TPE gas + TPE coal + TPE mineral oil = TPE electricity + TPE district heating + TPE loss|1|Balance Thermal Power Plant EVU. In energy balance, inputs and outputs cancel out
2010|TPE gas + TPE coal + TPE mineral oil = 0.929245283*TPE waste|1|Fraction TPE waste. Sum of other fuels is used as comparison for waste. (162+1019+1)/1272 Others divided by waste
2010|TPE waste + TPE coal + TPE mineral oil = 14.148148148*TPE gas|1|Fraction TPE gas. Sum of other fuels is used as comparison for gas. (1272+1019+1)/162 Others divided by gas
2010|TPE waste + TPE gas + TPE mineral oil = 1.408243376*TPE coal|1|Fraction TPE coal. Sum of other fuels is used as comparison for coal. (1272+162+1)/1019  Others divided by coal
2010|TPE district heating + TPE loss = 5.104477612*TPE electricity|1|Fraction TPE electricity. Sum of other outputs is used as comparison for electricity. (1171+881)/402 Others divided by electricity
2010|TPE electricity + TPE loss = 1.095644748*TPE district heating|1|Fraction TPE district heating. Sum of other outputs is used as comparison for district heating. (402+881)/1171 Others divided by district heating
2010|Ind gas = Ind electricity + Ind loss|1|Balance Industrial Plants. In energy balance, inputs and outputs cancel out
2010|Ind electricity = 0.533333333*Ind loss|1|Fraction Ind loss. Amount of district heating is used as comparison for loss. 8/15 district heating per loss
2010|STP local heating = 1.243243243*CHP local heating|1|Fraction local heating producers. CHP local heating production is used as reference. 46/37 STP local heating divided by CHP local heating
2010|Ind electricity = 0.006831768*CHP electricity|1|Fraction electricity producers 1. 8/1171 Ind electricity divided by TPE district heating VトトRIN 2008 sivulla??
2010|WWP electricity = 1.925925925*CHP electricity|1|Fraction electricity producers 2. CHP electricity production is used as reference. 52/27 WWP electricity divided by CHP electricity
2010|TPP electricity output = 2.259259259*CHP electricity|1|Fraction electricity producers 3. CHP electricity production is used as reference. 61/27 TPP electricity divided by CHP electricity
2010|TPE electricity = 14.888888888*CHP electricity|1|Fraction electricity producers 4. CHP electricity production is used as reference. 402/27 TPE electricity divided by CHP electricity
2010|Loss local heating = 0.057915058*STP local heating + 0.057915058*CHP local heating + 0.057915058*TPP local heating|1|Transmission loss local heating. Known loss divided by production. 15/(46+37+176)
2010|Loss electricity = 0.22*CHP electricity + 0.22*WWP electricity + 0.22*TPP electricity output + 0.22*TPE electricity + 0.22*Ind electricity|1|Transmission loss electricity. Known loss divided by production. 121/(27+52+61+402+8)
2010|Loss district heating = 0.102476516*TPE district heating|1|Transmission loss district heating. Known loss divided by production. 120/1171
2010|CES local heating = 0.217391304*STP local heating|1|Consumption in the Energy Sector local heating. STP local heating is used as reference. 10/46
2010|CES electricity = 4.259259259*CHP electricity|1|Consumption in the Energy Sector electricity. CHP electricity is used as reference. 115/27
2010|V renewable energy = 0.235294118*STP renewable energy|1|Vorketten renewable energy. STP renewable energy is used as reference. 8/34
2010|V coal = 0.103042198*TPE coal|1|Vorketten coal. TPE coal is used as reference. 105/1019
2010|V electricity = 14.425373134*TPE electricity|1|Vorketten electricity. TPE electricity is used as reference. 5799/402
2010|V gas = 14.181818181*CHP gas|1|Vorketten gas. CHP gas is used as reference. 468/33
2010|V mineral oil = 31.352941176*TPP mineral oil|1|Vorketten mineral oil. TPP mineral oil is used as reference. 533/17
2010|Bought electricity + CHP electricity + WWP electricity + TPP electricity output + TPE electricity + Ind electricity = STP electricity + TPP electricity input + Loss electricity + CES electricity + V electricity + Cons Ind electricity + Cons Traffic electricity + Cons Home electricity + Cons Commerce electricity|1|Electricity use balance. In energy balance, inputs and outputs cancel out
2010|STP local heating + CHP local heating + TPP local heating = Loss local heating + CES local heating + Cons Ind local heating + Cons Home local heating + Cons Commerce local heating|1|Local heating balance. In energy balance, inputs and outputs cancel out
2010|Bought district heating + TPE district heating = Loss district heating + Cons Ind district heating + Cons Home district heating + Cons Commerce district heating|1|District heating balance. In energy balance, inputs and outputs cancel out
2010|Cons Ind electricity = 2390|1|Consumed electricity industry
2010|Cons Traffic electricity = 225|1|Consumed electricity traffic
2010|Cons Home electricity = 1047|1|Consumed electricity households
2010|Cons Commerce electricity = 498|1|Consumed electricity commerce
2010|Cons Ind local heating = 6|1|Consumed local heating industry
2010|Cons Home local heating = 34|1|Consumed local heating households
2010|Cons Commerce local heating = 194|1|Consumed local heating commerce
2010|Cons Ind district heating = 394|1|Consumed districit heating industry
2010|Cons Home district heating = 73|1|Consumed districit heating households
2010|Cons Commerce district heating = 927|1|Consumed districit heating commerce
2025|STP renewable energy + STP electricity = STP local heating|1|Balance Solar Thermal Pump. In energy balance, inputs and outputs cancel out
2025|STP electricity = 0.352941176*STP renewable energy|1|Fraction STP renewable energy. Amount of electricity is used as comparison for renewable energy. 12/34 Electricity divided by renewable energy
2025|CHP gas + CHP renewable energy + CHP mineral oil = CHP local heating + CHP electricity + CHP loss|1|Balance CHP Plants. In energy balance, inputs and outputs cancel out
2025|CHP renewable energy + CHP mineral oil = 3.848484848*CHP gas|1|Fraction CHP gas. Sum of other fuels is used as comparison for gas. (116+11)/33 Others divided by gas
2025|CHP gas + CHP mineral oil = 0.379310344*CHP renewable energy|1|Sum of other fuels is used as comparison for renewable energy. Fraction CHP renewable energy. (33+11)/116 Others divided by renewable energy
2025|CHP electricity + CHP loss = 3.324324324*CHP local heating|1|Fraction CHP local heating. Sum of other outputs is used as comparison for local heating. (27+96)/37 Others divided by local heating.
2025|CHP local heating + CHP loss = 4.925925925*CHP electricity|1|Fraction CHP electricity. Sum of other outputs is used as comparison for electricity. (37+96)/27 Others divided by electricity
2025|WWP renewable energy = WWP electricity|1|Balance Water, Wind, Photovlotaics. In energy balance, inputs and outputs cancel out
2025|TPP electricity input + TPP mineral oil + TPP gas = TPP local heating + TPP electricity output + TPP loss|1|Balance Thermal Power Plant Pfaffenwald. In energy balance, inputs and outputs cancel out
2025|TPP mineral oil + TPP gas = 26*TPP electricity input|1|Fraction TPP electricity input. Sum of other fuels is used as comparison for electricity input. (17+217)/9 Others divided by electricity input
2025|TPP electricity input + TPP gas = 13.294117647*TPP mineral oil|1|Fraction TPP mineral oil. Sum of other fuels is used as comparison for mineral oil. (9+217)/17 Others divided by mineral oil
2025|TPP electricity output + TPP loss = 0.380681818*TPP local heating|1|Fraction TPP local heating. Sum of other outputs is used as comparison for local heating. (61+6)/176 Others divided by local heating
2025|TPP local heating +TPP loss = 2.983606557*TPP electricity output|1|Fraction TPP electricity output. Sum of other outputs is used as comparison for electricity. (176+6)/61 Others divided by electricity
2025|TPE waste + TPE gas + TPE coal + TPE mineral oil = TPE electricity + TPE district heating + TPE loss|1|Balance Thermal Power Plant EVU. In energy balance, inputs and outputs cancel out
2025|TPE gas + TPE coal + TPE mineral oil = 0.929245283*TPE waste|1|Fraction TPE waste. Sum of other fuels is used as comparison for waste. (162+1019+1)/1272 Others divided by waste
2025|TPE waste + TPE coal + TPE mineral oil = 14.148148148*TPE gas|1|Fraction TPE gas. Sum of other fuels is used as comparison for gas. (1272+1019+1)/162 Others divided by gas
2025|TPE waste + TPE gas + TPE mineral oil = 1.408243376*TPE coal|1|Fraction TPE coal. Sum of other fuels is used as comparison for coal. (1272+162+1)/1019  Others divided by coal
2025|TPE district heating + TPE loss = 5.104477612*TPE electricity|1|Fraction TPE electricity. Sum of other outputs is used as comparison for electricity. (1171+881)/402 Others divided by electricity
2025|TPE electricity + TPE loss = 1.095644748*TPE district heating|1|Fraction TPE district heating. Sum of other outputs is used as comparison for district heating. (402+881)/1171 Others divided by district heating
2025|Ind gas = Ind electricity + Ind loss|1|Balance Industrial Plants. In energy balance, inputs and outputs cancel out
2025|Ind electricity = 0.533333333*Ind loss|1|Fraction Ind loss. Amount of district heating is used as comparison for loss. 8/15 district heating per loss
2025|STP local heating = 1.243243243*CHP local heating|1|Fraction local heating producers. CHP local heating production is used as reference. 46/37 STP local heating divided by CHP local heating
2025|Ind electricity = 0.006831768*CHP electricity|1|Fraction electricity producers 1. 8/1171 Ind electricity divided by TPE district heating VトトRIN 2008 sivulla??
2025|WWP electricity = 1.925925925*CHP electricity|1|Fraction electricity producers 2. CHP electricity production is used as reference. 52/27 WWP electricity divided by CHP electricity
2025|TPP electricity output = 2.259259259*CHP electricity|1|Fraction electricity producers 3. CHP electricity production is used as reference. 61/27 TPP electricity divided by CHP electricity
2025|TPE electricity = 14.888888888*CHP electricity|1|Fraction electricity producers 4. CHP electricity production is used as reference. 402/27 TPE electricity divided by CHP electricity
2025|Loss local heating = 0.057915058*STP local heating + 0.057915058*CHP local heating + 0.057915058*TPP local heating|1|Transmission loss local heating. Known loss divided by production. 15/(46+37+176)
2025|Loss electricity = 0.22*CHP electricity + 0.22*WWP electricity + 0.22*TPP electricity output + 0.22*TPE electricity + 0.22*Ind electricity|1|Transmission loss electricity. Known loss divided by production. 121/(27+52+61+402+8)
2025|Loss district heating = 0.102476516*TPE district heating|1|Transmission loss district heating. Known loss divided by production. 120/1171
2025|CES local heating = 0.217391304*STP local heating|1|Consumption in the Energy Sector local heating. STP local heating is used as reference. 10/46
2025|CES electricity = 4.259259259*CHP electricity|1|Consumption in the Energy Sector electricity. CHP electricity is used as reference. 115/27
2025|V renewable energy = 0.235294118*STP renewable energy|1|Vorketten renewable energy. STP renewable energy is used as reference. 8/34
2025|V coal = 0.161923454*TPE coal|1|Vorketten coal. TPE coal is used as reference. 165/1019
2025|V electricity = 14.425373134*TPE electricity|1|Vorketten electricity. TPE electricity is used as reference. 5799/402
2025|V gas = 14.181818181*CHP gas|1|Vorketten gas. CHP gas is used as reference. 468/33
2025|V mineral oil = 31.352941176*TPP mineral oil|1|Vorketten mineral oil. TPP mineral oil is used as reference. 533/17
2025|Bought electricity + CHP electricity + WWP electricity + TPP electricity output + TPE electricity + Ind electricity = STP electricity + TPP electricity input + Loss electricity + CES electricity + V electricity + Cons Ind electricity + Cons Traffic electricity + Cons Home electricity + Cons Commerce electricity|1|Electricity use balance. In energy balance, inputs and outputs cancel out
2025|STP local heating + CHP local heating + TPP local heating = Loss local heating + CES local heating + Cons Ind local heating + Cons Home local heating + Cons Commerce local heating|1|Local heating balance. In energy balance, inputs and outputs cancel out
2025|Bought district heating + TPE district heating = Loss district heating + Cons Ind district heating + Cons Home district heating + Cons Commerce district heating|1|District heating balance. In energy balance, inputs and outputs cancel out
2025|Cons Ind electricity = 2499|1|Consumed electricity industry
2025|Cons Traffic electricity = 268|1|Consumed electricity traffic
2025|Cons Home electricity = 1137|1|Consumed electricity households
2025|Cons Commerce electricity = 485|1|Consumed electricity commerce
2025|Cons Ind local heating = 6|1|Consumed local heating industry
2025|Cons Home local heating = 38|1|Consumed local heating households
2025|Cons Commerce local heating = 162|1|Consumed local heating commerce
2025|Cons Ind district heating = 400|1|Consumed districit heating industry
2025|Cons Home district heating = 74|1|Consumed districit heating households
2025|Cons Commerce district heating = 941|1|Consumed districit heating commerce
</t2b>
</t2b>



Revision as of 12:27, 4 June 2014



Question

What are the amounts of energy produced, consumed, imported, and exported in Stuttgart?

Answer

⇤--#: . Rcode for using the ovariable is needed. --Jouni 23:03, 26 February 2013 (EET) (type: truth; paradigms: science: attack)

Rationale

There are several energy transformations that each describe a specific process of energy production or use. Per unit activity, there is a constant amount of different inputs and outputs into and from this process, respectively. These unit processes are used for Stuttgart in such a way that one critical input or output from each relevant energy transformation is listed here; all other inputs and outputs logically follow from the nature of the transformation process.

Data

Equations(GWh /a?)
ObsYearEquationDummyDescription
12008STP renewable energy + STP electricity = STP local heating1Balance Solar Thermal Pump. In energy balance, inputs and outputs cancel out
22008STP electricity = 0.363636364*STP renewable energy1Fraction STP renewable energy. Amount of electricity is used as comparison for renewable energy. 8/22 Electricity divided by renewable energy
32008CHP gas + CHP renewable energy + CHP mineral oil = CHP local heating + CHP electricity + CHP loss1Balance CHP Plants. In energy balance, inputs and outputs cancel out
42008CHP renewable energy + CHP mineral oil = 0.564814815*CHP gas1Fraction CHP gas. Sum of other fuels is used as comparison for gas. (108+14)/216 Others divided by gas
52008CHP gas + CHP mineral oil = 2.12962963*CHP renewable energy1Sum of other fuels is used as comparison for renewable energy. Fraction CHP renewable energy. (216+14)/108 Others divided by renewable energy
62008CHP electricity + CHP loss = 1.770491803*CHP local heating1Fraction CHP local heating. Sum of other outputs is used as comparison for local heating. (84+132)/122 Others divided by local heating.
72008CHP local heating + CHP loss = 3.023809524*CHP electricity1Fraction CHP electricity. Sum of other outputs is used as comparison for electricity. (122+132)/84 Others divided by electricity
82008WWP renewable energy = WWP electricity1Balance Water, Wind, Photovlotaics. In energy balance, inputs and outputs cancel out
92008TPP electricity input + TPP mineral oil + TPP gas = TPP local heating + TPP electricity output + TPP loss1Balance Thermal Power Plant Pfaffenwald. In energy balance, inputs and outputs cancel out
102008TPP mineral oil + TPP gas = 23.33333333*TPP electricity input1Fraction TPP electricity input. Sum of other fuels is used as comparison for electricity input. (43+167)/9 Others divided by electricity input
112008TPP electricity input + TPP gas = 4.093023256*TPP mineral oil1Fraction TPP mineral oil. Sum of other fuels is used as comparison for mineral oil. (9+167)/43 Others divided by mineral oil
122008TPP electricity output + TPP loss = 0.335365854*TPP local heating1Fraction TPP local heating. Sum of other outputs is used as comparison for local heating. (50+5)/164 Others divided by local heating
132008TPP local heating +TPP loss = 3.38*TPP electricity output1Fraction TPP electricity output. Sum of other outputs is used as comparison for electricity. (164+5)/50 Others divided by electricity
142008TPE waste + TPE gas + TPE coal + TPE mineral oil = TPE electricity + TPE district heating + TPE loss1Balance Thermal Power Plant EVU. In energy balance, inputs and outputs cancel out
152008TPE gas + TPE coal + TPE mineral oil = 1.04973357*TPE waste1Fraction TPE waste. Sum of other fuels is used as comparison for waste. (162+1019+1)/1126 Others divided by waste
162008TPE waste + TPE coal + TPE mineral oil = 13.24691358*TPE gas1Fraction TPE gas. Sum of other fuels is used as comparison for gas. (1126+1019+1)/162 Others divided by gas
172008TPE waste + TPE gas + TPE mineral oil = 1.264965653*TPE coal1Fraction TPE coal. Sum of other fuels is used as comparison for coal. (1126+162+1)/1019 Others divided by coal
182008TPE district heating + TPE loss = 5.089709763*TPE electricity1Fraction TPE electricity. Sum of other outputs is used as comparison for electricity. (1101+828)/379 Others divided by electricity
192008TPE electricity + TPE loss = 1.096276113*TPE district heating1Fraction TPE district heating. Sum of other outputs is used as comparison for district heating. (379 +828)/1101 Others divided by district heating
202008Ind gas = Ind electricity + Ind loss1Balance Industrial Plants. In energy balance, inputs and outputs cancel out
212008Ind electricity = 0.533333333*Ind loss1Fraction Ind loss. Amount of district heating is used as comparison for loss. 8/15 district heating per loss
222008STP local heating = 0.245901639*CHP local heating1Fraction local heating producers. CHP local heating production is used as reference. 30/122 STP local heating divided by CHP local heating
232008Ind electricity = 0.007266122*CHP electricity1Fraction electricity producers 1. 8/1101 Ind electricity divided by TPE district heating CORRECTED
242008WWP electricity = 0.797619048*CHP electricity1Fraction electricity producers 2. CHP electricity production is used as reference. 67/84 WWP electricity divided by CHP electricity
252008TPP electricity output = 0.595238095*CHP electricity1Fraction electricity producers 3. CHP electricity production is used as reference. 50/84 TPP electricity divided by CHP electricity
262008TPE electricity = 4.511904762*CHP electricity1Fraction electricity producers 4. CHP electricity production is used as reference. 379/84 TPE electricity divided by CHP electricity
272008Loss local heating = 0.041139241*STP local heating + 0.041139241*CHP local heating + 0.041139241*TPP local heating1Transmission loss local heating. Known loss divided by production. 13/(30+122+164)
282008Loss electricity = 0.221088435*CHP electricity + 0.221088435*WWP electricity + 0.221088435*TPP electricity output + 0.221088435*TPE electricity + 0.221088435*Ind electricity1Transmission loss electricity. Known loss divided by production. 130/(84+67+50+379+8)
292008Loss district heating = 0.109900091*TPE district heating1Transmission loss district heating. Known loss divided by production. 121/1101
302008CES local heating = 0.366666667*STP local heating1Consumption in the Energy Sector local heating. STP local heating is used as reference. 11/30
312008CES electricity = 1.392857143*CHP electricity1Consumption in the Energy Sector electricity. CHP electricity is used as reference. 117/84
322008V renewable energy = 0.272727273*STP renewable energy1Vorketten renewable energy. STP renewable energy is used as reference. 6/22
332008V coal = 0.103042198*TPE coal1Vorketten coal. TPE coal is used as reference. 105/1019
342008V electricity = 17.79683377*TPE electricity1Vorketten electricity. TPE electricity is used as reference. 6745/379
352008V gas = 2.027777778*CHP gas1Vorketten gas. CHP gas is used as reference. 438/216
362008V mineral oil = 12.3255814*TPP mineral oil1Vorketten mineral oil. TPP mineral oil is used as reference. 530/43
372008Bought electricity + CHP electricity + WWP electricity + TPP electricity output + TPE electricity + Ind electricity = STP electricity + TPP electricity input + Loss electricity + CES electricity + V electricity + Cons Ind electricity + Cons Traffic electricity + Cons Home electricity + Cons Commerce electricity1Electricity use balance. In energy balance, inputs and outputs cancel out
382008STP local heating + CHP local heating + TPP local heating = Loss local heating + CES local heating + Cons Ind local heating + Cons Home local heating + Cons Commerce local heating1Local heating balance. In energy balance, inputs and outputs cancel out
392008Bought district heating + TPE district heating = Loss district heating + Cons Ind district heating + Cons Home district heating + Cons Commerce district heating1District heating balance. In energy balance, inputs and outputs cancel out
402008Cons Ind electricity = 22571Consumed electricity industry
412008Cons Traffic electricity = 2241Consumed electricity traffic
422008Cons Home electricity = 10771Consumed electricity households
432008Cons Commerce electricity = 6951Consumed electricity commerce
442008Cons Ind local heating = 351Consumed local heating industry
452008Cons Home local heating = 541Consumed local heating households
462008Cons Commerce local heating = 2031Consumed local heating commerce
472008Cons Ind district heating = 5131Consumed districit heating industry
482008Cons Home district heating = 351Consumed districit heating households
492008Cons Commerce district heating = 8511Consumed districit heating commerce
502010STP renewable energy + STP electricity = STP local heating1Balance Solar Thermal Pump. In energy balance, inputs and outputs cancel out
512010STP electricity = 0.352941176*STP renewable energy1Fraction STP renewable energy. Amount of electricity is used as comparison for renewable energy. 12/34 Electricity divided by renewable energy
522010CHP gas + CHP renewable energy + CHP mineral oil = CHP local heating + CHP electricity + CHP loss1Balance CHP Plants. In energy balance, inputs and outputs cancel out
532010CHP renewable energy + CHP mineral oil = 3.848484848*CHP gas1Fraction CHP gas. Sum of other fuels is used as comparison for gas. (116+11)/33 Others divided by gas
542010CHP gas + CHP mineral oil = 0.379310344*CHP renewable energy1Sum of other fuels is used as comparison for renewable energy. Fraction CHP renewable energy. (33+11)/116 Others divided by renewable energy
552010CHP electricity + CHP loss = 3.324324324*CHP local heating1Fraction CHP local heating. Sum of other outputs is used as comparison for local heating. (27+96)/37 Others divided by local heating.
562010CHP local heating + CHP loss = 4.925925925*CHP electricity1Fraction CHP electricity. Sum of other outputs is used as comparison for electricity. (37+96)/27 Others divided by electricity
572010WWP renewable energy = WWP electricity1Balance Water, Wind, Photovlotaics. In energy balance, inputs and outputs cancel out
582010TPP electricity input + TPP mineral oil + TPP gas = TPP local heating + TPP electricity output + TPP loss1Balance Thermal Power Plant Pfaffenwald. In energy balance, inputs and outputs cancel out
592010TPP mineral oil + TPP gas = 26*TPP electricity input1Fraction TPP electricity input. Sum of other fuels is used as comparison for electricity input. (17+217)/9 Others divided by electricity input
602010TPP electricity input + TPP gas = 13.294117647*TPP mineral oil1Fraction TPP mineral oil. Sum of other fuels is used as comparison for mineral oil. (9+217)/17 Others divided by mineral oil
612010TPP electricity output + TPP loss = 0.380681818*TPP local heating1Fraction TPP local heating. Sum of other outputs is used as comparison for local heating. (61+6)/176 Others divided by local heating
622010TPP local heating +TPP loss = 2.983606557*TPP electricity output1Fraction TPP electricity output. Sum of other outputs is used as comparison for electricity. (176+6)/61 Others divided by electricity
632010TPE waste + TPE gas + TPE coal + TPE mineral oil = TPE electricity + TPE district heating + TPE loss1Balance Thermal Power Plant EVU. In energy balance, inputs and outputs cancel out
642010TPE gas + TPE coal + TPE mineral oil = 0.929245283*TPE waste1Fraction TPE waste. Sum of other fuels is used as comparison for waste. (162+1019+1)/1272 Others divided by waste
652010TPE waste + TPE coal + TPE mineral oil = 14.148148148*TPE gas1Fraction TPE gas. Sum of other fuels is used as comparison for gas. (1272+1019+1)/162 Others divided by gas
662010TPE waste + TPE gas + TPE mineral oil = 1.408243376*TPE coal1Fraction TPE coal. Sum of other fuels is used as comparison for coal. (1272+162+1)/1019 Others divided by coal
672010TPE district heating + TPE loss = 5.104477612*TPE electricity1Fraction TPE electricity. Sum of other outputs is used as comparison for electricity. (1171+881)/402 Others divided by electricity
682010TPE electricity + TPE loss = 1.095644748*TPE district heating1Fraction TPE district heating. Sum of other outputs is used as comparison for district heating. (402+881)/1171 Others divided by district heating
692010Ind gas = Ind electricity + Ind loss1Balance Industrial Plants. In energy balance, inputs and outputs cancel out
702010Ind electricity = 0.533333333*Ind loss1Fraction Ind loss. Amount of district heating is used as comparison for loss. 8/15 district heating per loss
712010STP local heating = 1.243243243*CHP local heating1Fraction local heating producers. CHP local heating production is used as reference. 46/37 STP local heating divided by CHP local heating
722010Ind electricity = 0.006831768*CHP electricity1Fraction electricity producers 1. 8/1171 Ind electricity divided by TPE district heating VトトRIN 2008 sivulla??
732010WWP electricity = 1.925925925*CHP electricity1Fraction electricity producers 2. CHP electricity production is used as reference. 52/27 WWP electricity divided by CHP electricity
742010TPP electricity output = 2.259259259*CHP electricity1Fraction electricity producers 3. CHP electricity production is used as reference. 61/27 TPP electricity divided by CHP electricity
752010TPE electricity = 14.888888888*CHP electricity1Fraction electricity producers 4. CHP electricity production is used as reference. 402/27 TPE electricity divided by CHP electricity
762010Loss local heating = 0.057915058*STP local heating + 0.057915058*CHP local heating + 0.057915058*TPP local heating1Transmission loss local heating. Known loss divided by production. 15/(46+37+176)
772010Loss electricity = 0.22*CHP electricity + 0.22*WWP electricity + 0.22*TPP electricity output + 0.22*TPE electricity + 0.22*Ind electricity1Transmission loss electricity. Known loss divided by production. 121/(27+52+61+402+8)
782010Loss district heating = 0.102476516*TPE district heating1Transmission loss district heating. Known loss divided by production. 120/1171
792010CES local heating = 0.217391304*STP local heating1Consumption in the Energy Sector local heating. STP local heating is used as reference. 10/46
802010CES electricity = 4.259259259*CHP electricity1Consumption in the Energy Sector electricity. CHP electricity is used as reference. 115/27
812010V renewable energy = 0.235294118*STP renewable energy1Vorketten renewable energy. STP renewable energy is used as reference. 8/34
822010V coal = 0.103042198*TPE coal1Vorketten coal. TPE coal is used as reference. 105/1019
832010V electricity = 14.425373134*TPE electricity1Vorketten electricity. TPE electricity is used as reference. 5799/402
842010V gas = 14.181818181*CHP gas1Vorketten gas. CHP gas is used as reference. 468/33
852010V mineral oil = 31.352941176*TPP mineral oil1Vorketten mineral oil. TPP mineral oil is used as reference. 533/17
862010Bought electricity + CHP electricity + WWP electricity + TPP electricity output + TPE electricity + Ind electricity = STP electricity + TPP electricity input + Loss electricity + CES electricity + V electricity + Cons Ind electricity + Cons Traffic electricity + Cons Home electricity + Cons Commerce electricity1Electricity use balance. In energy balance, inputs and outputs cancel out
872010STP local heating + CHP local heating + TPP local heating = Loss local heating + CES local heating + Cons Ind local heating + Cons Home local heating + Cons Commerce local heating1Local heating balance. In energy balance, inputs and outputs cancel out
882010Bought district heating + TPE district heating = Loss district heating + Cons Ind district heating + Cons Home district heating + Cons Commerce district heating1District heating balance. In energy balance, inputs and outputs cancel out
892010Cons Ind electricity = 23901Consumed electricity industry
902010Cons Traffic electricity = 2251Consumed electricity traffic
912010Cons Home electricity = 10471Consumed electricity households
922010Cons Commerce electricity = 4981Consumed electricity commerce
932010Cons Ind local heating = 61Consumed local heating industry
942010Cons Home local heating = 341Consumed local heating households
952010Cons Commerce local heating = 1941Consumed local heating commerce
962010Cons Ind district heating = 3941Consumed districit heating industry
972010Cons Home district heating = 731Consumed districit heating households
982010Cons Commerce district heating = 9271Consumed districit heating commerce
992025STP renewable energy + STP electricity = STP local heating1Balance Solar Thermal Pump. In energy balance, inputs and outputs cancel out
1002025STP electricity = 0.352941176*STP renewable energy1Fraction STP renewable energy. Amount of electricity is used as comparison for renewable energy. 12/34 Electricity divided by renewable energy
1012025CHP gas + CHP renewable energy + CHP mineral oil = CHP local heating + CHP electricity + CHP loss1Balance CHP Plants. In energy balance, inputs and outputs cancel out
1022025CHP renewable energy + CHP mineral oil = 3.848484848*CHP gas1Fraction CHP gas. Sum of other fuels is used as comparison for gas. (116+11)/33 Others divided by gas
1032025CHP gas + CHP mineral oil = 0.379310344*CHP renewable energy1Sum of other fuels is used as comparison for renewable energy. Fraction CHP renewable energy. (33+11)/116 Others divided by renewable energy
1042025CHP electricity + CHP loss = 3.324324324*CHP local heating1Fraction CHP local heating. Sum of other outputs is used as comparison for local heating. (27+96)/37 Others divided by local heating.
1052025CHP local heating + CHP loss = 4.925925925*CHP electricity1Fraction CHP electricity. Sum of other outputs is used as comparison for electricity. (37+96)/27 Others divided by electricity
1062025WWP renewable energy = WWP electricity1Balance Water, Wind, Photovlotaics. In energy balance, inputs and outputs cancel out
1072025TPP electricity input + TPP mineral oil + TPP gas = TPP local heating + TPP electricity output + TPP loss1Balance Thermal Power Plant Pfaffenwald. In energy balance, inputs and outputs cancel out
1082025TPP mineral oil + TPP gas = 26*TPP electricity input1Fraction TPP electricity input. Sum of other fuels is used as comparison for electricity input. (17+217)/9 Others divided by electricity input
1092025TPP electricity input + TPP gas = 13.294117647*TPP mineral oil1Fraction TPP mineral oil. Sum of other fuels is used as comparison for mineral oil. (9+217)/17 Others divided by mineral oil
1102025TPP electricity output + TPP loss = 0.380681818*TPP local heating1Fraction TPP local heating. Sum of other outputs is used as comparison for local heating. (61+6)/176 Others divided by local heating
1112025TPP local heating +TPP loss = 2.983606557*TPP electricity output1Fraction TPP electricity output. Sum of other outputs is used as comparison for electricity. (176+6)/61 Others divided by electricity
1122025TPE waste + TPE gas + TPE coal + TPE mineral oil = TPE electricity + TPE district heating + TPE loss1Balance Thermal Power Plant EVU. In energy balance, inputs and outputs cancel out
1132025TPE gas + TPE coal + TPE mineral oil = 0.929245283*TPE waste1Fraction TPE waste. Sum of other fuels is used as comparison for waste. (162+1019+1)/1272 Others divided by waste
1142025TPE waste + TPE coal + TPE mineral oil = 14.148148148*TPE gas1Fraction TPE gas. Sum of other fuels is used as comparison for gas. (1272+1019+1)/162 Others divided by gas
1152025TPE waste + TPE gas + TPE mineral oil = 1.408243376*TPE coal1Fraction TPE coal. Sum of other fuels is used as comparison for coal. (1272+162+1)/1019 Others divided by coal
1162025TPE district heating + TPE loss = 5.104477612*TPE electricity1Fraction TPE electricity. Sum of other outputs is used as comparison for electricity. (1171+881)/402 Others divided by electricity
1172025TPE electricity + TPE loss = 1.095644748*TPE district heating1Fraction TPE district heating. Sum of other outputs is used as comparison for district heating. (402+881)/1171 Others divided by district heating
1182025Ind gas = Ind electricity + Ind loss1Balance Industrial Plants. In energy balance, inputs and outputs cancel out
1192025Ind electricity = 0.533333333*Ind loss1Fraction Ind loss. Amount of district heating is used as comparison for loss. 8/15 district heating per loss
1202025STP local heating = 1.243243243*CHP local heating1Fraction local heating producers. CHP local heating production is used as reference. 46/37 STP local heating divided by CHP local heating
1212025Ind electricity = 0.006831768*CHP electricity1Fraction electricity producers 1. 8/1171 Ind electricity divided by TPE district heating VトトRIN 2008 sivulla??
1222025WWP electricity = 1.925925925*CHP electricity1Fraction electricity producers 2. CHP electricity production is used as reference. 52/27 WWP electricity divided by CHP electricity
1232025TPP electricity output = 2.259259259*CHP electricity1Fraction electricity producers 3. CHP electricity production is used as reference. 61/27 TPP electricity divided by CHP electricity
1242025TPE electricity = 14.888888888*CHP electricity1Fraction electricity producers 4. CHP electricity production is used as reference. 402/27 TPE electricity divided by CHP electricity
1252025Loss local heating = 0.057915058*STP local heating + 0.057915058*CHP local heating + 0.057915058*TPP local heating1Transmission loss local heating. Known loss divided by production. 15/(46+37+176)
1262025Loss electricity = 0.22*CHP electricity + 0.22*WWP electricity + 0.22*TPP electricity output + 0.22*TPE electricity + 0.22*Ind electricity1Transmission loss electricity. Known loss divided by production. 121/(27+52+61+402+8)
1272025Loss district heating = 0.102476516*TPE district heating1Transmission loss district heating. Known loss divided by production. 120/1171
1282025CES local heating = 0.217391304*STP local heating1Consumption in the Energy Sector local heating. STP local heating is used as reference. 10/46
1292025CES electricity = 4.259259259*CHP electricity1Consumption in the Energy Sector electricity. CHP electricity is used as reference. 115/27
1302025V renewable energy = 0.235294118*STP renewable energy1Vorketten renewable energy. STP renewable energy is used as reference. 8/34
1312025V coal = 0.161923454*TPE coal1Vorketten coal. TPE coal is used as reference. 165/1019
1322025V electricity = 14.425373134*TPE electricity1Vorketten electricity. TPE electricity is used as reference. 5799/402
1332025V gas = 14.181818181*CHP gas1Vorketten gas. CHP gas is used as reference. 468/33
1342025V mineral oil = 31.352941176*TPP mineral oil1Vorketten mineral oil. TPP mineral oil is used as reference. 533/17
1352025Bought electricity + CHP electricity + WWP electricity + TPP electricity output + TPE electricity + Ind electricity = STP electricity + TPP electricity input + Loss electricity + CES electricity + V electricity + Cons Ind electricity + Cons Traffic electricity + Cons Home electricity + Cons Commerce electricity1Electricity use balance. In energy balance, inputs and outputs cancel out
1362025STP local heating + CHP local heating + TPP local heating = Loss local heating + CES local heating + Cons Ind local heating + Cons Home local heating + Cons Commerce local heating1Local heating balance. In energy balance, inputs and outputs cancel out
1372025Bought district heating + TPE district heating = Loss district heating + Cons Ind district heating + Cons Home district heating + Cons Commerce district heating1District heating balance. In energy balance, inputs and outputs cancel out
1382025Cons Ind electricity = 24991Consumed electricity industry
1392025Cons Traffic electricity = 2681Consumed electricity traffic
1402025Cons Home electricity = 11371Consumed electricity households
1412025Cons Commerce electricity = 4851Consumed electricity commerce
1422025Cons Ind local heating = 61Consumed local heating industry
1432025Cons Home local heating = 381Consumed local heating households
1442025Cons Commerce local heating = 1621Consumed local heating commerce
1452025Cons Ind district heating = 4001Consumed districit heating industry
1462025Cons Home district heating = 741Consumed districit heating households
1472025Cons Commerce district heating = 9411Consumed districit heating commerce

There are no nonlinearities.

Calculations

+ Show code

See also

Urgenche research project 2011 - 2014: city-level climate change mitigation
Urgenche pages

Urgenche main page · Category:Urgenche · Urgenche project page (password-protected)

Relevant data
Building stock data in Urgenche‎ · Building regulations in Finland · Concentration-response to PM2.5 · Emission factors for burning processes · ERF of indoor dampness on respiratory health effects · ERF of several environmental pollutions · General criteria for land use · Indoor environment quality (IEQ) factors · Intake fractions of PM · Land use in Urgenche · Land use and boundary in Urgenche · Energy use of buildings

Relevant methods
Building model · Energy balance · Health impact assessment · Opasnet map · Help:Drawing graphs · OpasnetUtils‎ · Recommended R functions‎ · Using summary tables‎

City Kuopio
Climate change policies and health in Kuopio (assessment) · Climate change policies in Kuopio (plausible city-level climate policies) · Health impacts of energy consumption in Kuopio · Building stock in Kuopio · Cost curves for energy (prioritization of options) · Energy balance in Kuopio (energy data) · Energy consumption and GHG emissions in Kuopio by sector · Energy consumption classes (categorisation) · Energy consumption of heating of buildings in Kuopio · Energy transformations (energy production and use processes) · Fuels used by Haapaniemi energy plant · Greenhouse gas emissions in Kuopio · Haapaniemi energy plant in Kuopio · Land use in Kuopio · Building data availability in Kuopio · Password-protected pages: File:Heat use in Kuopio.csv · Kuopio housing

City Basel
Buildings in Basel (password-protected)

Energy balances
Energy balance in Basel · Energy balance in Kuopio · Energy balance in Stuttgart · Energy balance in Suzhou


Keywords

References


Related files

<mfanonymousfilelist></mfanonymousfilelist>