Energy balance in Kuopio: Difference between revisions

From Opasnet
Jump to navigation Jump to search
(→‎Formula: code works!)
Line 19: Line 19:


<t2b index="Equation,Col,Observation" locations="Result,Description" unit="-">
<t2b index="Equation,Col,Observation" locations="Result,Description" unit="-">
Balance CHP Plants|CHP_peat|-1|In energy balance, inputs and outputs cancel out
Balance CHP Plants|CHP peat|-1|In energy balance, inputs and outputs cancel out
Balance CHP Plants|CHP_renewable|-1|
Balance CHP Plants|CHP renewable|-1|
Balance CHP Plants|CHP_oil|-1|
Balance CHP Plants|CHP oil|-1|
Balance CHP Plants|CHP_heat|1|
Balance CHP Plants|CHP heat|1|
Balance CHP Plants|CHP_electricity|1|
Balance CHP Plants|CHP electricity|1|
Balance CHP Plants|CHP_loss|1|
Balance CHP Plants|CHP loss|1|
Fraction CHP renewable|CHP_peat|-1|Sum of other fuels is used as comparison for renewables
Fraction CHP renewable|CHP peat|-1|Sum of other fuels is used as comparison for renewables
Fraction CHP renewable|CHP_oil|-1|
Fraction CHP renewable|CHP oil|-1|
Fraction CHP renewable|CHP_renewable|20.931|(1435.7+199)/78.1 Others divided by renewables
Fraction CHP renewable|CHP renewable|20.931|(1435.7+199)/78.1 Others divided by renewables
Fraction CHP oil|CHP_peat|-1|Sum of other fuels is used as comparison for oil
Fraction CHP oil|CHP peat|-1|Sum of other fuels is used as comparison for oil
Fraction CHP oil|CHP_renewable|-1|
Fraction CHP oil|CHP renewable|-1|
Fraction CHP oil|CHP_oil|20.931|(1435.7+199)/78.1 Others divided by oil
Fraction CHP oil|CHP oil|20.931|(1435.7+199)/78.1 Others divided by oil
Fraction CHP heat|CHP_electricity|-1|Sum of other outputs is used as comparison for heat
Fraction CHP heat|CHP electricity|-1|Sum of other outputs is used as comparison for heat
Fraction CHP heat|CHP_loss|-1|
Fraction CHP heat|CHP loss|-1|
Fraction CHP heat|CHP_heat|0.689|(428.6+244.6)/977.7 Others divided by heat
Fraction CHP heat|CHP heat|0.689|(428.6+244.6)/977.7 Others divided by heat
Fraction CHP electricity|CHP_heat|-1|Sum of other outputs is used as comparison for electricity
Fraction CHP electricity|CHP heat|-1|Sum of other outputs is used as comparison for electricity
Fraction CHP electricity|CHP_loss|-1|
Fraction CHP electricity|CHP loss|-1|
Fraction CHP electricity|CHP_electricity|2.852|(977.7+244.6)/428.6 Others divided by electricity
Fraction CHP electricity|CHP electricity|2.852|(977.7+244.6)/428.6 Others divided by electricity
Balance H Plants|H_biogas|-1|In energy balance, inputs and outputs cancel out.
Balance H Plants|H biogas|-1|In energy balance, inputs and outputs cancel out.
Balance H Plants|H_oil|-1|
Balance H Plants|H oil|-1|
Balance H Plants|H_heat|1|
Balance H Plants|H heat|1|
Balance H Plants|H_loss|1|
Balance H Plants|H loss|1|
Fraction H biogas|H_oil|-1|Amount of oil is used as comparison for biogas
Fraction H biogas|H oil|-1|Amount of oil is used as comparison for biogas
Fraction H biogas|H_biogas|18.973|70.2/3.7 Oil divided by biogas
Fraction H biogas|H biogas|18.973|70.2/3.7 Oil divided by biogas
Fraction H loss|H_heat|-1|Amount of heat is used as comparison for loss.
Fraction H loss|H heat|-1|Amount of heat is used as comparison for loss.
Fraction H loss|H_loss|14.082|69/4.9 Heat per loss
Fraction H loss|H loss|14.082|69/4.9 Heat per loss
Balance Industrial Plants|Ind_peat|-1|In energy balance, inputs and outputs cancel out.
Balance Industrial Plants|Ind peat|-1|In energy balance, inputs and outputs cancel out.
Balance Industrial Plants|Ind_oil|-1|
Balance Industrial Plants|Ind oil|-1|
Balance Industrial Plants|Ind_renewable|-1|
Balance Industrial Plants|Ind renewable|-1|
Balance Industrial Plants|Ind_electricity|1|
Balance Industrial Plants|Ind electricity|1|
Balance Industrial Plants|Ind_process_heat|1|
Balance Industrial Plants|Ind process heat|1|
Balance Industrial Plants|Ind_loss|1|
Balance Industrial Plants|Ind loss|1|
Fraction Industrial peat|Ind_oil|-1|Sum of other fuels is used as comparison for peat.
Fraction Industrial peat|Ind oil|-1|Sum of other fuels is used as comparison for peat.
Fraction Industrial peat|Ind_renewable|-1|
Fraction Industrial peat|Ind renewable|-1|
Fraction Industrial peat|Ind_peat|2.014|(82.4+527.8)/303 Others divided by peat.
Fraction Industrial peat|Ind peat|2.014|(82.4+527.8)/303 Others divided by peat.
Fraction Industrial oil|Ind_peat|-1|
Fraction Industrial oil|Ind peat|-1|
Fraction Industrial oil|Ind_renewable|-1|
Fraction Industrial oil|Ind renewable|-1|
Fraction Industrial oil|Ind_oil|10.083|(303+527.8)/82.4 Others divided by oil.
Fraction Industrial oil|Ind oil|10.083|(303+527.8)/82.4 Others divided by oil.
Fraction Industrial electricity|Ind_process_heat|-1|Sum of other fuels is used as comparison for electricity
Fraction Industrial electricity|Ind process heat|-1|Sum of other fuels is used as comparison for electricity
Fraction Industrial electricity|Ind_loss|-1|Heat loss = 104 = 303+82.4+527.8-123.8-685.4
Fraction Industrial electricity|Ind loss|-1|Heat loss = 104 = 303+82.4+527.8-123.8-685.4
Fraction Industrial electricity|Ind_electricity|6.376|(685.4+104)/123.8
Fraction Industrial electricity|Ind electricity|6.376|(685.4+104)/123.8
Fraction Industrial process heat|Ind_electricity|-1|Sum of other fuels is used as comparison for process heat.
Fraction Industrial process heat|Ind electricity|-1|Sum of other fuels is used as comparison for process heat.
Fraction Industrial process heat|Ind_loss|-1|
Fraction Industrial process heat|Ind loss|-1|
Fraction Industrial process heat|Ind_process_heat|0.332|(123.8+104)/685.4 Sum of other produtcs divided by process heat.
Fraction Industrial process heat|Ind process heat|0.332|(123.8+104)/685.4 Sum of other produtcs divided by process heat.
Transmission loss electricity in CHP|CHP_electricity|-0.0858|47.4/(428.6+123.8)
Transmission loss electricity in CHP|CHP electricity|-0.0858|47.4/(428.6+123.8)
Transmission loss electricity in CHP|Loss_electricity|1|
Transmission loss electricity in CHP|Loss electricity|1|
Transmission loss electricity in Industry|Ind_electricity|-0.0858|47.4/(428.6+123.8)
Transmission loss electricity in Industry|Ind electricity|-0.0858|47.4/(428.6+123.8)
Transmission loss electricity in Industry|Loss_electricity|1|
Transmission loss electricity in Industry|Loss electricity|1|
Transmission loss heat in CHP|CHP_heat|-0.0855|89.5/(977.7+69)
Transmission loss heat in CHP|CHP heat|-0.0855|89.5/(977.7+69)
Transmission loss heat in CHP|Loss_heat|1|
Transmission loss heat in CHP|Loss heat|1|
Transmission loss heat in Industry|Ind_process_heat|-0.0855|89.5/(977.7+69)
Transmission loss heat in Industry|Ind process heat|-0.0855|89.5/(977.7+69)
Transmission loss heat in Industry|Loss_heat|1|
Transmission loss heat in Industry|Loss heat|1|
Electricity use balance|Bought_electricity|-1|In energy balance, inputs and outputs cancel out.
Electricity use balance|Bought electricity|-1|In energy balance, inputs and outputs cancel out.
Electricity use balance|CHP_electricity|-1|
Electricity use balance|CHP electricity|-1|
Electricity use balance|Ind_electricity|-1|
Electricity use balance|Ind electricity|-1|
Electricity use balance|Loss_electricity|1|
Electricity use balance|Loss electricity|1|
Electricity use balance|Cons_Home_electricity|1|
Electricity use balance|Cons Home electricity|1|
Electricity use balance|Cons_Ind_electricity|1|
Electricity use balance|Cons Ind electricity|1|
Electricity use balance|Cons_Commerce_electricity|1|
Electricity use balance|Cons Commerce electricity|1|
Electricity use balance|Cons_Municip_electricity|1|
Electricity use balance|Cons Municip electricity|1|
Heat use balance|CHP_heat|-1|In energy balance, inputs and outputs cancel out.
Heat use balance|CHP heat|-1|In energy balance, inputs and outputs cancel out.
Heat use balance|H_heat|-1|
Heat use balance|H heat|-1|
Heat use balance|Loss_heat|1|
Heat use balance|Loss heat|1|
Heat use balance|Cons_Home_heat|1|
Heat use balance|Cons Home heat|1|
Heat use balance|Cons_Ind_heat|1|
Heat use balance|Cons Ind heat|1|
Heat use balance|Cons_Commerce_heat|1|
Heat use balance|Cons Commerce heat|1|
Heat use balance|Cons_Municip_heat|1|
Heat use balance|Cons Municip heat|1|
Consumed electricity home|Cons_Home_electricity|1|This must be given.
Consumed electricity home|Cons Home electricity|1|This must be given.
Consumed electricity industry|Cons_Ind_electricity|1|This must be given.
Consumed electricity industry|Cons Ind electricity|1|This must be given.
Consumed electricity commerce|Cons_Commerce_electricity|1|This must be given.
Consumed electricity commerce|Cons Commerce electricity|1|This must be given.
Consumed electricity municipality|Cons_Municip_electricity|1|This must be given.
Consumed electricity municipality|Cons Municip electricity|1|This must be given.
Consumed heat home|Cons_Home_heat|1|This must be given.
Consumed heat home|Cons Home heat|1|This must be given.
Consumed heat industry|Cons_Ind_heat|1|This must be given.
Consumed heat industry|Cons Ind heat|1|This must be given.
Consumed heat commerce|Cons_Commerce_heat|1|This must be given.
Consumed heat commerce|Cons Commerce heat|1|This must be given.
Consumed heat municipality|Cons_Municip_heat|1|This must be given.
Consumed heat municipality|Cons Municip heat|1|This must be given.
</t2b>
</t2b>



Revision as of 20:14, 28 August 2012



Question

What are the amounts of energy produced, consumed, imported, and exported in Kuopio?

Answer

Rationale

Numbers are based on op_fi:Energiatase/Kuopio.

There are several energy transformations that each describe a specific process of energy production or use. Per unit activity, there is a constant amount of different inputs and outputs into and from this process, respectively. These unit processes are used for Kuopio in such a way that one critical input or output from each relevant energy transformation is listed here; all other inputs and outputs logically follow from the nature of the transformation process.

Data

Energy balance in Kuopio: Difference between revisions(-)
ObsEquationColResultDescription
1Balance CHP PlantsCHP peat-1In energy balance, inputs and outputs cancel out
2Balance CHP PlantsCHP renewable-1
3Balance CHP PlantsCHP oil-1
4Balance CHP PlantsCHP heat1
5Balance CHP PlantsCHP electricity1
6Balance CHP PlantsCHP loss1
7Fraction CHP renewableCHP peat-1Sum of other fuels is used as comparison for renewables
8Fraction CHP renewableCHP oil-1
9Fraction CHP renewableCHP renewable20.931(1435.7+199)/78.1 Others divided by renewables
10Fraction CHP oilCHP peat-1Sum of other fuels is used as comparison for oil
11Fraction CHP oilCHP renewable-1
12Fraction CHP oilCHP oil20.931(1435.7+199)/78.1 Others divided by oil
13Fraction CHP heatCHP electricity-1Sum of other outputs is used as comparison for heat
14Fraction CHP heatCHP loss-1
15Fraction CHP heatCHP heat0.689(428.6+244.6)/977.7 Others divided by heat
16Fraction CHP electricityCHP heat-1Sum of other outputs is used as comparison for electricity
17Fraction CHP electricityCHP loss-1
18Fraction CHP electricityCHP electricity2.852(977.7+244.6)/428.6 Others divided by electricity
19Balance H PlantsH biogas-1In energy balance, inputs and outputs cancel out.
20Balance H PlantsH oil-1
21Balance H PlantsH heat1
22Balance H PlantsH loss1
23Fraction H biogasH oil-1Amount of oil is used as comparison for biogas
24Fraction H biogasH biogas18.97370.2/3.7 Oil divided by biogas
25Fraction H lossH heat-1Amount of heat is used as comparison for loss.
26Fraction H lossH loss14.08269/4.9 Heat per loss
27Balance Industrial PlantsInd peat-1In energy balance, inputs and outputs cancel out.
28Balance Industrial PlantsInd oil-1
29Balance Industrial PlantsInd renewable-1
30Balance Industrial PlantsInd electricity1
31Balance Industrial PlantsInd process heat1
32Balance Industrial PlantsInd loss1
33Fraction Industrial peatInd oil-1Sum of other fuels is used as comparison for peat.
34Fraction Industrial peatInd renewable-1
35Fraction Industrial peatInd peat2.014(82.4+527.8)/303 Others divided by peat.
36Fraction Industrial oilInd peat-1
37Fraction Industrial oilInd renewable-1
38Fraction Industrial oilInd oil10.083(303+527.8)/82.4 Others divided by oil.
39Fraction Industrial electricityInd process heat-1Sum of other fuels is used as comparison for electricity
40Fraction Industrial electricityInd loss-1Heat loss = 104 = 303+82.4+527.8-123.8-685.4
41Fraction Industrial electricityInd electricity6.376(685.4+104)/123.8
42Fraction Industrial process heatInd electricity-1Sum of other fuels is used as comparison for process heat.
43Fraction Industrial process heatInd loss-1
44Fraction Industrial process heatInd process heat0.332(123.8+104)/685.4 Sum of other produtcs divided by process heat.
45Transmission loss electricity in CHPCHP electricity-0.085847.4/(428.6+123.8)
46Transmission loss electricity in CHPLoss electricity1
47Transmission loss electricity in IndustryInd electricity-0.085847.4/(428.6+123.8)
48Transmission loss electricity in IndustryLoss electricity1
49Transmission loss heat in CHPCHP heat-0.085589.5/(977.7+69)
50Transmission loss heat in CHPLoss heat1
51Transmission loss heat in IndustryInd process heat-0.085589.5/(977.7+69)
52Transmission loss heat in IndustryLoss heat1
53Electricity use balanceBought electricity-1In energy balance, inputs and outputs cancel out.
54Electricity use balanceCHP electricity-1
55Electricity use balanceInd electricity-1
56Electricity use balanceLoss electricity1
57Electricity use balanceCons Home electricity1
58Electricity use balanceCons Ind electricity1
59Electricity use balanceCons Commerce electricity1
60Electricity use balanceCons Municip electricity1
61Heat use balanceCHP heat-1In energy balance, inputs and outputs cancel out.
62Heat use balanceH heat-1
63Heat use balanceLoss heat1
64Heat use balanceCons Home heat1
65Heat use balanceCons Ind heat1
66Heat use balanceCons Commerce heat1
67Heat use balanceCons Municip heat1
68Consumed electricity homeCons Home electricity1This must be given.
69Consumed electricity industryCons Ind electricity1This must be given.
70Consumed electricity commerceCons Commerce electricity1This must be given.
71Consumed electricity municipalityCons Municip electricity1This must be given.
72Consumed heat homeCons Home heat1This must be given.
73Consumed heat industryCons Ind heat1This must be given.
74Consumed heat commerceCons Commerce heat1This must be given.
75Consumed heat municipalityCons Municip heat1This must be given.

Dependencies

Formula

Cons_Home_electricity:

Cons_Ind_electricity:

Cons_Commerce_electricity:

Cons_Municip_electricity:

Cons_Home_heat:

Cons_Ind_heat:

Cons_Commerce_heat:

Cons_Municip_heat:

+ Show code

See also

Urgenche research project 2011 - 2014: city-level climate change mitigation
Urgenche pages

Urgenche main page · Category:Urgenche · Urgenche project page (password-protected)

Relevant data
Building stock data in Urgenche‎ · Building regulations in Finland · Concentration-response to PM2.5 · Emission factors for burning processes · ERF of indoor dampness on respiratory health effects · ERF of several environmental pollutions · General criteria for land use · Indoor environment quality (IEQ) factors · Intake fractions of PM · Land use in Urgenche · Land use and boundary in Urgenche · Energy use of buildings

Relevant methods
Building model · Energy balance · Health impact assessment · Opasnet map · Help:Drawing graphs · OpasnetUtils‎ · Recommended R functions‎ · Using summary tables‎

City Kuopio
Climate change policies and health in Kuopio (assessment) · Climate change policies in Kuopio (plausible city-level climate policies) · Health impacts of energy consumption in Kuopio · Building stock in Kuopio · Cost curves for energy (prioritization of options) · Energy balance in Kuopio (energy data) · Energy consumption and GHG emissions in Kuopio by sector · Energy consumption classes (categorisation) · Energy consumption of heating of buildings in Kuopio · Energy transformations (energy production and use processes) · Fuels used by Haapaniemi energy plant · Greenhouse gas emissions in Kuopio · Haapaniemi energy plant in Kuopio · Land use in Kuopio · Building data availability in Kuopio · Password-protected pages: File:Heat use in Kuopio.csv · Kuopio housing

City Basel
Buildings in Basel (password-protected)

Energy balances
Energy balance in Basel · Energy balance in Kuopio · Energy balance in Stuttgart · Energy balance in Suzhou


Keywords

References


Related files

<mfanonymousfilelist></mfanonymousfilelist>