Energy balance in Kuopio: Difference between revisions
Jump to navigation
Jump to search
(→Formula: code works!) |
m (→Data) |
||
Line 19: | Line 19: | ||
<t2b index="Equation,Col,Observation" locations="Result,Description" unit="-"> | <t2b index="Equation,Col,Observation" locations="Result,Description" unit="-"> | ||
Balance CHP Plants| | Balance CHP Plants|CHP peat|-1|In energy balance, inputs and outputs cancel out | ||
Balance CHP Plants| | Balance CHP Plants|CHP renewable|-1| | ||
Balance CHP Plants| | Balance CHP Plants|CHP oil|-1| | ||
Balance CHP Plants| | Balance CHP Plants|CHP heat|1| | ||
Balance CHP Plants| | Balance CHP Plants|CHP electricity|1| | ||
Balance CHP Plants| | Balance CHP Plants|CHP loss|1| | ||
Fraction CHP renewable| | Fraction CHP renewable|CHP peat|-1|Sum of other fuels is used as comparison for renewables | ||
Fraction CHP renewable| | Fraction CHP renewable|CHP oil|-1| | ||
Fraction CHP renewable| | Fraction CHP renewable|CHP renewable|20.931|(1435.7+199)/78.1 Others divided by renewables | ||
Fraction CHP oil| | Fraction CHP oil|CHP peat|-1|Sum of other fuels is used as comparison for oil | ||
Fraction CHP oil| | Fraction CHP oil|CHP renewable|-1| | ||
Fraction CHP oil| | Fraction CHP oil|CHP oil|20.931|(1435.7+199)/78.1 Others divided by oil | ||
Fraction CHP heat| | Fraction CHP heat|CHP electricity|-1|Sum of other outputs is used as comparison for heat | ||
Fraction CHP heat| | Fraction CHP heat|CHP loss|-1| | ||
Fraction CHP heat| | Fraction CHP heat|CHP heat|0.689|(428.6+244.6)/977.7 Others divided by heat | ||
Fraction CHP electricity| | Fraction CHP electricity|CHP heat|-1|Sum of other outputs is used as comparison for electricity | ||
Fraction CHP electricity| | Fraction CHP electricity|CHP loss|-1| | ||
Fraction CHP electricity| | Fraction CHP electricity|CHP electricity|2.852|(977.7+244.6)/428.6 Others divided by electricity | ||
Balance H Plants| | Balance H Plants|H biogas|-1|In energy balance, inputs and outputs cancel out. | ||
Balance H Plants| | Balance H Plants|H oil|-1| | ||
Balance H Plants| | Balance H Plants|H heat|1| | ||
Balance H Plants| | Balance H Plants|H loss|1| | ||
Fraction H biogas| | Fraction H biogas|H oil|-1|Amount of oil is used as comparison for biogas | ||
Fraction H biogas| | Fraction H biogas|H biogas|18.973|70.2/3.7 Oil divided by biogas | ||
Fraction H loss| | Fraction H loss|H heat|-1|Amount of heat is used as comparison for loss. | ||
Fraction H loss| | Fraction H loss|H loss|14.082|69/4.9 Heat per loss | ||
Balance Industrial Plants| | Balance Industrial Plants|Ind peat|-1|In energy balance, inputs and outputs cancel out. | ||
Balance Industrial Plants| | Balance Industrial Plants|Ind oil|-1| | ||
Balance Industrial Plants| | Balance Industrial Plants|Ind renewable|-1| | ||
Balance Industrial Plants| | Balance Industrial Plants|Ind electricity|1| | ||
Balance Industrial Plants| | Balance Industrial Plants|Ind process heat|1| | ||
Balance Industrial Plants| | Balance Industrial Plants|Ind loss|1| | ||
Fraction Industrial peat| | Fraction Industrial peat|Ind oil|-1|Sum of other fuels is used as comparison for peat. | ||
Fraction Industrial peat| | Fraction Industrial peat|Ind renewable|-1| | ||
Fraction Industrial peat| | Fraction Industrial peat|Ind peat|2.014|(82.4+527.8)/303 Others divided by peat. | ||
Fraction Industrial oil| | Fraction Industrial oil|Ind peat|-1| | ||
Fraction Industrial oil| | Fraction Industrial oil|Ind renewable|-1| | ||
Fraction Industrial oil| | Fraction Industrial oil|Ind oil|10.083|(303+527.8)/82.4 Others divided by oil. | ||
Fraction Industrial electricity| | Fraction Industrial electricity|Ind process heat|-1|Sum of other fuels is used as comparison for electricity | ||
Fraction Industrial electricity| | Fraction Industrial electricity|Ind loss|-1|Heat loss = 104 = 303+82.4+527.8-123.8-685.4 | ||
Fraction Industrial electricity| | Fraction Industrial electricity|Ind electricity|6.376|(685.4+104)/123.8 | ||
Fraction Industrial process heat| | Fraction Industrial process heat|Ind electricity|-1|Sum of other fuels is used as comparison for process heat. | ||
Fraction Industrial process heat| | Fraction Industrial process heat|Ind loss|-1| | ||
Fraction Industrial process heat| | Fraction Industrial process heat|Ind process heat|0.332|(123.8+104)/685.4 Sum of other produtcs divided by process heat. | ||
Transmission loss electricity in CHP| | Transmission loss electricity in CHP|CHP electricity|-0.0858|47.4/(428.6+123.8) | ||
Transmission loss electricity in CHP| | Transmission loss electricity in CHP|Loss electricity|1| | ||
Transmission loss electricity in Industry| | Transmission loss electricity in Industry|Ind electricity|-0.0858|47.4/(428.6+123.8) | ||
Transmission loss electricity in Industry| | Transmission loss electricity in Industry|Loss electricity|1| | ||
Transmission loss heat in CHP| | Transmission loss heat in CHP|CHP heat|-0.0855|89.5/(977.7+69) | ||
Transmission loss heat in CHP| | Transmission loss heat in CHP|Loss heat|1| | ||
Transmission loss heat in Industry| | Transmission loss heat in Industry|Ind process heat|-0.0855|89.5/(977.7+69) | ||
Transmission loss heat in Industry| | Transmission loss heat in Industry|Loss heat|1| | ||
Electricity use balance| | Electricity use balance|Bought electricity|-1|In energy balance, inputs and outputs cancel out. | ||
Electricity use balance| | Electricity use balance|CHP electricity|-1| | ||
Electricity use balance| | Electricity use balance|Ind electricity|-1| | ||
Electricity use balance| | Electricity use balance|Loss electricity|1| | ||
Electricity use balance| | Electricity use balance|Cons Home electricity|1| | ||
Electricity use balance| | Electricity use balance|Cons Ind electricity|1| | ||
Electricity use balance| | Electricity use balance|Cons Commerce electricity|1| | ||
Electricity use balance| | Electricity use balance|Cons Municip electricity|1| | ||
Heat use balance| | Heat use balance|CHP heat|-1|In energy balance, inputs and outputs cancel out. | ||
Heat use balance| | Heat use balance|H heat|-1| | ||
Heat use balance| | Heat use balance|Loss heat|1| | ||
Heat use balance| | Heat use balance|Cons Home heat|1| | ||
Heat use balance| | Heat use balance|Cons Ind heat|1| | ||
Heat use balance| | Heat use balance|Cons Commerce heat|1| | ||
Heat use balance| | Heat use balance|Cons Municip heat|1| | ||
Consumed electricity home| | Consumed electricity home|Cons Home electricity|1|This must be given. | ||
Consumed electricity industry| | Consumed electricity industry|Cons Ind electricity|1|This must be given. | ||
Consumed electricity commerce| | Consumed electricity commerce|Cons Commerce electricity|1|This must be given. | ||
Consumed electricity municipality| | Consumed electricity municipality|Cons Municip electricity|1|This must be given. | ||
Consumed heat home| | Consumed heat home|Cons Home heat|1|This must be given. | ||
Consumed heat industry| | Consumed heat industry|Cons Ind heat|1|This must be given. | ||
Consumed heat commerce| | Consumed heat commerce|Cons Commerce heat|1|This must be given. | ||
Consumed heat municipality| | Consumed heat municipality|Cons Municip heat|1|This must be given. | ||
</t2b> | </t2b> | ||
Revision as of 20:14, 28 August 2012
[show] |
---|
Question
What are the amounts of energy produced, consumed, imported, and exported in Kuopio?
Answer
Rationale
Numbers are based on op_fi:Energiatase/Kuopio.
There are several energy transformations that each describe a specific process of energy production or use. Per unit activity, there is a constant amount of different inputs and outputs into and from this process, respectively. These unit processes are used for Kuopio in such a way that one critical input or output from each relevant energy transformation is listed here; all other inputs and outputs logically follow from the nature of the transformation process.
Data
Obs | Equation | Col | Result | Description |
---|---|---|---|---|
1 | Balance CHP Plants | CHP peat | -1 | In energy balance, inputs and outputs cancel out |
2 | Balance CHP Plants | CHP renewable | -1 | |
3 | Balance CHP Plants | CHP oil | -1 | |
4 | Balance CHP Plants | CHP heat | 1 | |
5 | Balance CHP Plants | CHP electricity | 1 | |
6 | Balance CHP Plants | CHP loss | 1 | |
7 | Fraction CHP renewable | CHP peat | -1 | Sum of other fuels is used as comparison for renewables |
8 | Fraction CHP renewable | CHP oil | -1 | |
9 | Fraction CHP renewable | CHP renewable | 20.931 | (1435.7+199)/78.1 Others divided by renewables |
10 | Fraction CHP oil | CHP peat | -1 | Sum of other fuels is used as comparison for oil |
11 | Fraction CHP oil | CHP renewable | -1 | |
12 | Fraction CHP oil | CHP oil | 20.931 | (1435.7+199)/78.1 Others divided by oil |
13 | Fraction CHP heat | CHP electricity | -1 | Sum of other outputs is used as comparison for heat |
14 | Fraction CHP heat | CHP loss | -1 | |
15 | Fraction CHP heat | CHP heat | 0.689 | (428.6+244.6)/977.7 Others divided by heat |
16 | Fraction CHP electricity | CHP heat | -1 | Sum of other outputs is used as comparison for electricity |
17 | Fraction CHP electricity | CHP loss | -1 | |
18 | Fraction CHP electricity | CHP electricity | 2.852 | (977.7+244.6)/428.6 Others divided by electricity |
19 | Balance H Plants | H biogas | -1 | In energy balance, inputs and outputs cancel out. |
20 | Balance H Plants | H oil | -1 | |
21 | Balance H Plants | H heat | 1 | |
22 | Balance H Plants | H loss | 1 | |
23 | Fraction H biogas | H oil | -1 | Amount of oil is used as comparison for biogas |
24 | Fraction H biogas | H biogas | 18.973 | 70.2/3.7 Oil divided by biogas |
25 | Fraction H loss | H heat | -1 | Amount of heat is used as comparison for loss. |
26 | Fraction H loss | H loss | 14.082 | 69/4.9 Heat per loss |
27 | Balance Industrial Plants | Ind peat | -1 | In energy balance, inputs and outputs cancel out. |
28 | Balance Industrial Plants | Ind oil | -1 | |
29 | Balance Industrial Plants | Ind renewable | -1 | |
30 | Balance Industrial Plants | Ind electricity | 1 | |
31 | Balance Industrial Plants | Ind process heat | 1 | |
32 | Balance Industrial Plants | Ind loss | 1 | |
33 | Fraction Industrial peat | Ind oil | -1 | Sum of other fuels is used as comparison for peat. |
34 | Fraction Industrial peat | Ind renewable | -1 | |
35 | Fraction Industrial peat | Ind peat | 2.014 | (82.4+527.8)/303 Others divided by peat. |
36 | Fraction Industrial oil | Ind peat | -1 | |
37 | Fraction Industrial oil | Ind renewable | -1 | |
38 | Fraction Industrial oil | Ind oil | 10.083 | (303+527.8)/82.4 Others divided by oil. |
39 | Fraction Industrial electricity | Ind process heat | -1 | Sum of other fuels is used as comparison for electricity |
40 | Fraction Industrial electricity | Ind loss | -1 | Heat loss = 104 = 303+82.4+527.8-123.8-685.4 |
41 | Fraction Industrial electricity | Ind electricity | 6.376 | (685.4+104)/123.8 |
42 | Fraction Industrial process heat | Ind electricity | -1 | Sum of other fuels is used as comparison for process heat. |
43 | Fraction Industrial process heat | Ind loss | -1 | |
44 | Fraction Industrial process heat | Ind process heat | 0.332 | (123.8+104)/685.4 Sum of other produtcs divided by process heat. |
45 | Transmission loss electricity in CHP | CHP electricity | -0.0858 | 47.4/(428.6+123.8) |
46 | Transmission loss electricity in CHP | Loss electricity | 1 | |
47 | Transmission loss electricity in Industry | Ind electricity | -0.0858 | 47.4/(428.6+123.8) |
48 | Transmission loss electricity in Industry | Loss electricity | 1 | |
49 | Transmission loss heat in CHP | CHP heat | -0.0855 | 89.5/(977.7+69) |
50 | Transmission loss heat in CHP | Loss heat | 1 | |
51 | Transmission loss heat in Industry | Ind process heat | -0.0855 | 89.5/(977.7+69) |
52 | Transmission loss heat in Industry | Loss heat | 1 | |
53 | Electricity use balance | Bought electricity | -1 | In energy balance, inputs and outputs cancel out. |
54 | Electricity use balance | CHP electricity | -1 | |
55 | Electricity use balance | Ind electricity | -1 | |
56 | Electricity use balance | Loss electricity | 1 | |
57 | Electricity use balance | Cons Home electricity | 1 | |
58 | Electricity use balance | Cons Ind electricity | 1 | |
59 | Electricity use balance | Cons Commerce electricity | 1 | |
60 | Electricity use balance | Cons Municip electricity | 1 | |
61 | Heat use balance | CHP heat | -1 | In energy balance, inputs and outputs cancel out. |
62 | Heat use balance | H heat | -1 | |
63 | Heat use balance | Loss heat | 1 | |
64 | Heat use balance | Cons Home heat | 1 | |
65 | Heat use balance | Cons Ind heat | 1 | |
66 | Heat use balance | Cons Commerce heat | 1 | |
67 | Heat use balance | Cons Municip heat | 1 | |
68 | Consumed electricity home | Cons Home electricity | 1 | This must be given. |
69 | Consumed electricity industry | Cons Ind electricity | 1 | This must be given. |
70 | Consumed electricity commerce | Cons Commerce electricity | 1 | This must be given. |
71 | Consumed electricity municipality | Cons Municip electricity | 1 | This must be given. |
72 | Consumed heat home | Cons Home heat | 1 | This must be given. |
73 | Consumed heat industry | Cons Ind heat | 1 | This must be given. |
74 | Consumed heat commerce | Cons Commerce heat | 1 | This must be given. |
75 | Consumed heat municipality | Cons Municip heat | 1 | This must be given. |
Dependencies