<t2b index="Row,Year,Activity,Fuel,Observation" locations="Unit,Result,Description" unit="-">
1|2006|CHP plants|Heat|ktoe|129|
2|2006|Road transport|Petrochemical products|ktoe|54|
3|2006|Heating|Renewables and waste|ktoe|6|
4|2006|Heating|Electricity|ktoe|10|
5|2006|Heating|Heat|ktoe|96|
6|2006|Other energy consumption|Petrochemical products|ktoe|9|
7|2006|Other energy consumption|Renewables and waste|ktoe|45|
8|2006|Other energy consumption|Electricity|ktoe|51|
9|2006|Petroleum refineries|Renewables and waste|ktoe|0|
</t2b>


==Rationale==
==Rationale==
Line 26: Line 15:


There are several [[energy transformations]] that each describe a specific process of energy production or use. Per unit activity, there is a constant amount of different inputs and outputs into and from this process, respectively. These unit processes are used for Kuopio in such a way that one critical input or output from each relevant energy transformation is listed here; all other inputs and outputs logically follow from the nature of the transformation process.
There are several [[energy transformations]] that each describe a specific process of energy production or use. Per unit activity, there is a constant amount of different inputs and outputs into and from this process, respectively. These unit processes are used for Kuopio in such a way that one critical input or output from each relevant energy transformation is listed here; all other inputs and outputs logically follow from the nature of the transformation process.
===Data===
<t2b index="Row,Col,Observation" locations="Value,Description" unit="-">
Balance CHP Plants|CHP_peat|-1|In energy balance, inputs and outputs cancel out
Balance CHP Plants|CHP_renewable|-1|
Balance CHP Plants|CHP_oil|-1|
Balance CHP Plants|CHP_heat|1|
Balance CHP Plants|CHP_electricity|1|
Balance CHP Plants|CHP_loss|1|
Fraction CHP renewable|CHP_peat|-1|Sum of other fuels is used as comparison for renewables
Fraction CHP renewable|CHP_oil|-1|
Fraction CHP renewable|CHP_renewable|20.931|(1435.7+199)/78.1 Others divided by renewables
Fraction CHP oil|CHP_peat|-1|Sum of other fuels is used as comparison for oil
Fraction CHP oil|CHP_renewable|-1|
Fraction CHP oil|CHP_oil|20.931|(1435.7+199)/78.1 Others divided by oil
Fraction CHP heat|CHP_electricity|-1|Sum of other outputs is used as comparison for heat
Fraction CHP heat|CHP_loss|-1|
Fraction CHP heat|CHP_heat|0.689|(428.6+244.6)/977.7 Others divided by heat
Fraction CHP electricity|CHP_heat|-1|Sum of other outputs is used as comparison for electricity
Fraction CHP electricity|CHP_loss|-1|
Fraction CHP electricity|CHP_electricity|2.852|(977.7+244.6)/428.6 Others divided by electricity
Amount CHP heat|CHP_heat|1|The amount of heat consumed must be given.
Balance H Plants|H_biogas|-1|In energy balance, inputs and outputs cancel out.
Balance H Plants|H_oil|-1|
Balance H Plants|H_heat|1|
Balance H Plants|H_loss|1|
Fraction H biogas|H_oil|-1|Amount of oil is used as comparison for biogas
Fraction H biogas|H_biogas|18.973|70.2/3.7 Oil divided by biogas
Fraction H loss|H_heat|-1|Amount of heat is used as comparison for loss.
Fraction H loss|H_loss|14.082|69/4.9 Heat per loss
Balance Industrial Plants|Ind_peat|-1|In energy balance, inputs and outputs cancel out.
Balance Industrial Plants|Ind_oil|-1|
Balance Industrial Plants|Ind_renewable|-1|
Balance Industrial Plants|Ind_electricity|1|
Balance Industrial Plants|Ind_process_heat|1|
Balance Industrial Plants|Ind_loss|1|
Fraction Industrial peat|Ind_oil|-1|Sum of other fuels is used as comparison for peat.
Fraction Industrial peat|Ind_renewable|-1|
Fraction Industrial peat|Ind_peat|2.014|(82.4+527.8)/303 Others divided by peat.
Fraction Industrial oil|Ind_peat|-1|
Fraction Industrial oil|Ind_renewable|-1|
Fraction Industrial oil|Ind_oil|10.083|(303+527.8)/82.4 Others divided by oil.
Fraction Industrial electricity|Ind_process_heat|-1|Sum of other fuels is used as comparison for electricity
Fraction Industrial electricity|Ind_loss|-1|Heat loss = 104 = 303+82.4+527.8-123.8-685.4
Fraction Industrial electricity|Ind_electricity|6.376|(685.4+104)/123.8
Fraction Industrial process heat|Ind_electricity|-1|Sum of other fuels is used as comparison for process heat.
Fraction Industrial process heat|Ind_loss|-1|
Fraction Industrial process heat|Ind_process_heat|0.332|(123.8+104)/685.4 Sum of other produtcs divided by process heat.
Transmission loss electricity|CHP_electricity|-1|
Transmission loss electricity|Ind_electricity|-1|
Transmission loss electricity|Loss_electricity|11.654|(428.6+123.8)/47.4
Transmission loss heat|CHP_heat|-1|
Transmission loss heat|H_heat|-1|
Transmission loss heat|Loss_heat|11.695|(977.7+69)/89.5
Electricity use balance|Bought_electricity|-1|In energy balance, inputs and outputs cancel out.
Electricity use balance|CHP_electricity|-1|
Electricity use balance|Ind_electricity|-1|
Electricity use balance|Loss_electricity|1|
Electricity use balance|Cons_Home_electricity|1|
Electricity use balance|Cons_Ind_electricity|1|
Electricity use balance|Cons_Commerce_electricity|1|
Electricity use balance|Cons_Municip_electricity|1|
Heat use balance|CHP_heat|-1|In energy balance, inputs and outputs cancel out.
Heat use balance|H_heat|-1|
Heat use balance|Loss_heat|1|
Heat use balance|Cons_Home_heat|1|
Heat use balance|Cons_Ind_heat|1|
Heat use balance|Cons_Commerce_heat|1|
Heat use balance|Cons_Municip_heat|1|
Consumed electricity home|Cons_Home_electricity|1|This must be given.
Consumed electricity industry|Cons_Ind_electricity|1|This must be given.
Consumed electricity commerce|Cons_Commerce_electricity|1|This must be given.
Consumed electricity municipality|Cons_Municip_electricity|1|This must be given.
Consumed heat home|Cons_Home_heat|1|This must be given.
Consumed heat industry|Cons_Ind_heat|1|This must be given.
Consumed heat commerce|Cons_Commerce_heat|1|This must be given.
Consumed heat municipality|Cons_Municip_heat|1|This must be given.
</t2b>


=== Dependencies ===
=== Dependencies ===


=== Formula ===
=== Formula ===
<rcode variables="
name:Cons_Home_electricity|default:296|
name:Cons_Ind_electricity|default:204|
name:Cons_Commerce_electricity|default:334|
name:Cons_Municip_electricity|default:50.3|
name:Cons_Home_heat|default:303|
name:Cons_Ind_heat|default:57.1|
name:Cons_Commerce_heat|default:224|
name:Cons_Municip_heat|default:386
">
library(OpasnetUtils)
library(xtable)
vars <- c(
"CHP_peat",
"CHP_renewable",
"CHP_oil",
"CHP_heat",
"CHP_electricity",
"CHP_loss",
"H_biogas",
"H_oil",
"H_heat",
"H_loss",
"Ind_peat",
"Ind_oil",
"Ind_renewable",
"Ind_electricity",
"Ind_process_heat",
"Ind_loss",
"Loss_electricity",
"Loss_heat",
"Bought_electricity",
"Cons_Home_electricity",
"Cons_Ind_electricity",
"Cons_Commerce_electricity",
"Cons_Municip_electricity",
"Cons_Home_heat",
"Cons_Ind_heat",
"Cons_Commerce_heat",
"Cons_Municip_heat"
)
out <- c(rep(0, 19),
Cons_Home_electricity,
Cons_Ind_electricity,
Cons_Commerce_electricity,
Cons_Municip_electricity,
Cons_Home_heat,
Cons_Ind_heat,
Cons_Commerce_heat,
Cons_Municip_heat
)
out <- solve(ETM, out)
</rcode>


==See also==
==See also==

Revision as of 19:16, 28 August 2012



Question

What are the amounts of energy produced, consumed, imported, and exported in Kuopio?

Answer

Rationale

Numbers are based on op_fi:Energiatase/Kuopio.

There are several energy transformations that each describe a specific process of energy production or use. Per unit activity, there is a constant amount of different inputs and outputs into and from this process, respectively. These unit processes are used for Kuopio in such a way that one critical input or output from each relevant energy transformation is listed here; all other inputs and outputs logically follow from the nature of the transformation process.

Data

Energy balance in Kuopio: Difference between revisions(-)
ObsRowColValueDescription
1Balance CHP PlantsCHP_peat-1In energy balance, inputs and outputs cancel out
2Balance CHP PlantsCHP_renewable-1
3Balance CHP PlantsCHP_oil-1
4Balance CHP PlantsCHP_heat1
5Balance CHP PlantsCHP_electricity1
6Balance CHP PlantsCHP_loss1
7Fraction CHP renewableCHP_peat-1Sum of other fuels is used as comparison for renewables
8Fraction CHP renewableCHP_oil-1
9Fraction CHP renewableCHP_renewable20.931(1435.7+199)/78.1 Others divided by renewables
10Fraction CHP oilCHP_peat-1Sum of other fuels is used as comparison for oil
11Fraction CHP oilCHP_renewable-1
12Fraction CHP oilCHP_oil20.931(1435.7+199)/78.1 Others divided by oil
13Fraction CHP heatCHP_electricity-1Sum of other outputs is used as comparison for heat
14Fraction CHP heatCHP_loss-1
15Fraction CHP heatCHP_heat0.689(428.6+244.6)/977.7 Others divided by heat
16Fraction CHP electricityCHP_heat-1Sum of other outputs is used as comparison for electricity
17Fraction CHP electricityCHP_loss-1
18Fraction CHP electricityCHP_electricity2.852(977.7+244.6)/428.6 Others divided by electricity
19Amount CHP heatCHP_heat1The amount of heat consumed must be given.
20Balance H PlantsH_biogas-1In energy balance, inputs and outputs cancel out.
21Balance H PlantsH_oil-1
22Balance H PlantsH_heat1
23Balance H PlantsH_loss1
24Fraction H biogasH_oil-1Amount of oil is used as comparison for biogas
25Fraction H biogasH_biogas18.97370.2/3.7 Oil divided by biogas
26Fraction H lossH_heat-1Amount of heat is used as comparison for loss.
27Fraction H lossH_loss14.08269/4.9 Heat per loss
28Balance Industrial PlantsInd_peat-1In energy balance, inputs and outputs cancel out.
29Balance Industrial PlantsInd_oil-1
30Balance Industrial PlantsInd_renewable-1
31Balance Industrial PlantsInd_electricity1
32Balance Industrial PlantsInd_process_heat1
33Balance Industrial PlantsInd_loss1
34Fraction Industrial peatInd_oil-1Sum of other fuels is used as comparison for peat.
35Fraction Industrial peatInd_renewable-1
36Fraction Industrial peatInd_peat2.014(82.4+527.8)/303 Others divided by peat.
37Fraction Industrial oilInd_peat-1
38Fraction Industrial oilInd_renewable-1
39Fraction Industrial oilInd_oil10.083(303+527.8)/82.4 Others divided by oil.
40Fraction Industrial electricityInd_process_heat-1Sum of other fuels is used as comparison for electricity
41Fraction Industrial electricityInd_loss-1Heat loss = 104 = 303+82.4+527.8-123.8-685.4
42Fraction Industrial electricityInd_electricity6.376(685.4+104)/123.8
43Fraction Industrial process heatInd_electricity-1Sum of other fuels is used as comparison for process heat.
44Fraction Industrial process heatInd_loss-1
45Fraction Industrial process heatInd_process_heat0.332(123.8+104)/685.4 Sum of other produtcs divided by process heat.
46Transmission loss electricityCHP_electricity-1
47Transmission loss electricityInd_electricity-1
48Transmission loss electricityLoss_electricity11.654(428.6+123.8)/47.4
49Transmission loss heatCHP_heat-1
50Transmission loss heatH_heat-1
51Transmission loss heatLoss_heat11.695(977.7+69)/89.5
52Electricity use balanceBought_electricity-1In energy balance, inputs and outputs cancel out.
53Electricity use balanceCHP_electricity-1
54Electricity use balanceInd_electricity-1
55Electricity use balanceLoss_electricity1
56Electricity use balanceCons_Home_electricity1
57Electricity use balanceCons_Ind_electricity1
58Electricity use balanceCons_Commerce_electricity1
59Electricity use balanceCons_Municip_electricity1
60Heat use balanceCHP_heat-1In energy balance, inputs and outputs cancel out.
61Heat use balanceH_heat-1
62Heat use balanceLoss_heat1
63Heat use balanceCons_Home_heat1
64Heat use balanceCons_Ind_heat1
65Heat use balanceCons_Commerce_heat1
66Heat use balanceCons_Municip_heat1
67Consumed electricity homeCons_Home_electricity1This must be given.
68Consumed electricity industryCons_Ind_electricity1This must be given.
69Consumed electricity commerceCons_Commerce_electricity1This must be given.
70Consumed electricity municipalityCons_Municip_electricity1This must be given.
71Consumed heat homeCons_Home_heat1This must be given.
72Consumed heat industryCons_Ind_heat1This must be given.
73Consumed heat commerceCons_Commerce_heat1This must be given.
74Consumed heat municipalityCons_Municip_heat1This must be given.


Dependencies

Formula

Cons_Home_electricity:

Cons_Ind_electricity:

Cons_Commerce_electricity:

Cons_Municip_electricity:

Cons_Home_heat:

Cons_Ind_heat:

Cons_Commerce_heat:

Cons_Municip_heat:

+ Show code


See also

Urgenche research project 2011 - 2014: city-level climate change mitigation
Urgenche pages

Urgenche main page · Category:Urgenche · Urgenche project page (password-protected)

Relevant data
Building stock data in Urgenche‎ · Building regulations in Finland · Concentration-response to PM2.5 · Emission factors for burning processes · ERF of indoor dampness on respiratory health effects · ERF of several environmental pollutions · General criteria for land use · Indoor environment quality (IEQ) factors · Intake fractions of PM · Land use in Urgenche · Land use and boundary in Urgenche · Energy use of buildings

Relevant methods
Building model · Energy balance · Health impact assessment · Opasnet map · Help:Drawing graphs · OpasnetUtils‎ · Recommended R functions‎ · Using summary tables‎

City Kuopio
Climate change policies and health in Kuopio (assessment) · Climate change policies in Kuopio (plausible city-level climate policies) · Health impacts of energy consumption in Kuopio · Building stock in Kuopio · Cost curves for energy (prioritization of options) · Energy balance in Kuopio (energy data) · Energy consumption and GHG emissions in Kuopio by sector · Energy consumption classes (categorisation) · Energy consumption of heating of buildings in Kuopio · Energy transformations (energy production and use processes) · Fuels used by Haapaniemi energy plant · Greenhouse gas emissions in Kuopio · Haapaniemi energy plant in Kuopio · Land use in Kuopio · Building data availability in Kuopio · Password-protected pages: File:Heat use in Kuopio.csv · Kuopio housing

City Basel
Buildings in Basel (password-protected)

Energy balances
Energy balance in Basel · Energy balance in Kuopio · Energy balance in Stuttgart · Energy balance in Suzhou


Keywords

References


Related files

<mfanonymousfilelist></mfanonymousfilelist>