Climate change policies in Helsinki: Difference between revisions
(scope updated) |
mNo edit summary |
||
(44 intermediate revisions by 5 users not shown) | |||
Line 5: | Line 5: | ||
[[Category:Heating]] | [[Category:Heating]] | ||
[[Category:PM2.5]] | [[Category:PM2.5]] | ||
{{assessment|moderator=Jouni | {{assessment|moderator=Jouni}} | ||
:''This assessment was used for training in [[Decision analysis and risk management 2015]] course. To see student contributions, see [http://en.opasnet.org/en-opwiki/index.php?title=Climate_change_policies_in_Helsinki&oldid=37124 a previous version]. | |||
== Scope == | == Scope == | ||
Line 20: | Line 21: | ||
* Jouni Tuomisto (THL), the coordinator of the assessment | * Jouni Tuomisto (THL), the coordinator of the assessment | ||
* | * The participants of the [[Decision analysis and risk management 2015]] course. | ||
* Helsinki Environment Centre | * Helsinki Environment Centre | ||
* Siemens and the City Performance Tool experts | * Siemens and the City Performance Tool experts | ||
Line 26: | Line 27: | ||
=== Boundaries === | === Boundaries === | ||
* Time: 2010- | * Time: 2010-2060 | ||
* Spatial: the city of | * Spatial: the city of Helsinki | ||
=== Decisions and scenarios === | === Decisions and scenarios === | ||
* | Energy saving policy: Relates to the shares of efficiency types when new buildings are built (ovariable efficiencyShares). | ||
* | *BAU: Business as usual, no change to the energy efficiency of buildings. | ||
*Energy saving moderate: No change to the energy efficiency of buildings. | |||
*Energy saving total: Starting from the year 2020 buildings are built to be more energy efficient. 25 percentage points of production shifts from low-energy buildings to passive buildings. Starting from the year 2040 another 10 percentage points of production shifts from low-energy to passive. | |||
Fuel policy: Helen increases the share of wood-based biofuels used in Hanasaari and Salmisaari power plants to 40 % of fuels used. Both burn 40 % wood pellets and 60 % coal. (ovariable fuelShares) | |||
*BAU: Business and usual, both power plants continue burning only 5-10 % biofuel. | |||
*40 bio: Shift to biofuels, starting from the year 2020 the share of wood-based fuels increase by 24 percentage points and coal's share decrease by the same amount. | |||
Energy saving policy (ovariable renovationRate) | |||
*BAU: Business as usual, every year 1 % of all buildings over 30 years old are renovated to increase their energy efficiency. | |||
*Energy saving moderate: Increased energy renovation, every year 2 % of all buildings over 30 years old are renovated to increase their energy efficiency. | |||
*Energy saving total: Greatly increased energy renovation, every year 3 % of all buildings over 30 years old are renovated to increase their energy efficiency. | |||
See also decisions in [[Climate change policies and health in Kuopio]]. | |||
{{hidden| | |||
<t2b name="Decisions" index='Decision maker,Decision,Option,Variable,Cell,Change,Unit' obs='Amount' desc='Description' unit='-'> | |||
Builders|EnergySavingPolicy|BAU|efficiencyShares||Add||0| | |||
Builders|EnergySavingPolicy|Energy saving moderate|efficiencyShares||Add||0| | |||
Builders|EnergySavingPolicy|Energy saving total|efficiencyShares|Efficiency:Passive;Time:2020,2030|Add|fraction|0.25|All input must be given in units that are used in respective ovariables. | |||
Builders|EnergySavingPolicy|Energy saving total|efficiencyShares|Efficiency:Passive;Time:2040,2050,2060|Add|fraction|0.1| | |||
Builders|EnergySavingPolicy|Energy saving total|efficiencyShares|Efficiency:Low-energy;Time:2020,2030|Add|fraction|-0.25| | |||
Builders|EnergySavingPolicy|Energy saving total|efficiencyShares|Efficiency:Low-energy;Time:2040,2050,2060|Add|fraction|-0.1| | |||
Helen|FuelPolicy|BAU|fuelShares||Add||0| | |||
Helen|FuelPolicy|40 bio|fuelShares|Burner:Large fluidized bed;Fuel:Wood;Time:2020,2030,2040,2050,2060|Add|fraction|0.24| | |||
Helen|FuelPolicy|40 bio|fuelShares|Burner:Large fluidized bed;Fuel:Coal;Time:2020,2030,2040,2050,2060|Add|fraction|-0.24| | |||
Building owner|EnergySavingPolicy|BAU|renovationRate||Multiply|1 /a|1|Assumes BAU renovation rate = 1%/a for buildings >30 a old | |||
Building owner|EnergySavingPolicy|Energy saving moderate|renovationRate||Multiply|1 /a|2| | |||
Building owner|EnergySavingPolicy|Energy saving total|renovationRate||Multiply|1 /a|3|3%/a is 100 % in 20 a | |||
</t2b> | |||
}} | |||
=== Timing === | === Timing === | ||
Line 46: | Line 77: | ||
== Rationale == | == Rationale == | ||
[[image: | [[image:Helsinki energy decision 2015.png|thumb|400px|Causal diagram of climate change policies in Helsinki. This assessment only relates to the building stock part of the diagram.]] | ||
=== Stakeholders === | === Stakeholders === | ||
Line 54: | Line 85: | ||
=== Dependencies === | === Dependencies === | ||
* [[Building stock in Helsinki]] | |||
* | * [[Energy use of buildings]] | ||
* [[Emission factors for burning processes]] | |||
* [[Climate change policies and health in Kuopio#Direct inputs]] | |||
* | * [[District heating production units in Helsinki metropolitan area]] | ||
* | * [[Exposure to PM2.5 in Finland]] | ||
* [[OpasnetUtils/Drafts]] | |||
* | * [[Health impact assessment]] | ||
* | * [[Disease risk]] | ||
* | * [[Exposure-response function]] | ||
* | * [[Burden of disease in Finland]] | ||
* [[Outdoor air temperature in Finland]] | |||
* [[Unit price of carbon emission permits]] | |||
; Data files | |||
* {{#l:Climate policies Helsinki data.zip}} | * {{#l:Climate policies Helsinki data.zip}} | ||
* {{#l:Climate policies Helsinki additional data.zip}} | * {{#l:Climate policies Helsinki additional data.zip}} | ||
Line 84: | Line 109: | ||
** VTT energy efficiency expert Jyri Nieminen | ** VTT energy efficiency expert Jyri Nieminen | ||
** Tampere University of Technology: EPAT: Energy saving potential in Finnish housing stock by 2050. [http://www.tut.fi/ee/Materiaali/Epat/EPAT_loppuraportti.pdf] See especially section 4.2.4. | ** Tampere University of Technology: EPAT: Energy saving potential in Finnish housing stock by 2050. [http://www.tut.fi/ee/Materiaali/Epat/EPAT_loppuraportti.pdf] See especially section 4.2.4. | ||
==== Discussions ==== | ==== Discussions ==== | ||
Line 126: | Line 134: | ||
=== Calculations === | === Calculations === | ||
[http://en.opasnet.org/en-opwiki/index.php?title=Special:RTools&id= | *[http://en.opasnet.org/en-opwiki/index.php?title=Special:RTools&id=bGzkpGQwG2P0xTs5 Model run 15.6.2015] | ||
*[http://en.opasnet.org/en-opwiki/index.php?title=Special:RTools&id=iOrQttDzoCgmuKw2 Model run 24.6.2015] (new structure of building model) | |||
<rcode graphics=1> | <rcode graphics=1> | ||
Line 143: | Line 152: | ||
objects.latest("Op_en6007", code_name = "answer") # [[OpasnetUtils/Drafts]] findrest | objects.latest("Op_en6007", code_name = "answer") # [[OpasnetUtils/Drafts]] findrest | ||
obstime <- data.frame(Startyear = c( | obstime <- data.frame(Startyear = c((198:206) * 10)) # Observation years must be defined for an assessment. | ||
BS <- 24 | BS <- 24 # base_size = font size in graphs | ||
heating_before <- FALSE # Should heatingShares be calculated before renovate and timepoints (or after)? | heating_before <- FALSE # Should heatingShares be calculated before renovate and timepoints (or after)? | ||
efficiency_before <- TRUE # Should efficiencyShares be calculated before renovate and timepoints (or after)? | efficiency_before <- TRUE # Should efficiencyShares be calculated before renovate and timepoints (or after)? | ||
figstofile <- FALSE | figstofile <- FALSE | ||
## Additional index needed in followup of ovariables efficiencyShares and stockBuildings | ## Additional index needed in followup of ovariables efficiencyShares and stockBuildings | ||
###################### | ############################ City-specific data | ||
# | |||
# | |||
# | ##########################!------------------------------------------------ | ||
## Decisions | |||
decisions <- opbase.data("Op_en7063", subset = "Decisions") # [[Climate change policies in Helsinki]] | |||
####### | ## Building stock | ||
objects.latest("Op_en7115", code_name = "stockBuildings") # [[Building stock in Helsinki]] | |||
objects.latest("Op_en7115", code_name = "changeBuildings") # [[Building stock in Helsinki]] | |||
objects.latest("Op_en7115", code_name = "renovationRate") # [[Building stock in Helsinki]] | |||
objects.latest("Op_en7115", code_name = "renovationShares") # [[Building stock in Helsinki]] | |||
objects.latest("Op_en5488", code_name = "efficiencyShares") # [[Energy use of buildings]] | |||
## | objects.latest("Op_en6289", code_name = "buildings") # [[Building model]] # Generic building model. | ||
#### | ## Energy use | ||
objects.latest(" | objects.latest("Op_en5488", code_name = "energyUseAnnual") # [[Energy use of buildings]] annual version of energyUse | ||
#objects.latest("Op_en5488", code_name = "efficiencyRatio") # [[Energy use of buildings]] DEFAULT USED | |||
# objects.latest("Op_en5488", code_name = "renovationRatio") # [[Energy use of buildings]] DEFAULT USED | |||
# | ## Energy and emissions | ||
objects.latest("Op_en7311", code_name = "emissionLocations") # [[Helsinki energy production]] also heatingShares | |||
objects.latest("Op_en2791", code_name = "emissionFactors") # [[Emission factors for burning processes]] | |||
objects.latest("Op_en2791", code_name = "emissions") # [[Emission factors for burning processes]] | |||
objects.latest("Op_en7311", code_name = "fuelShares") # [[Helsinki energy production]] | |||
# | |||
# | |||
# | |||
# | |||
## Exposure | |||
objects.latest("Op_en5813", code_name = "exposure") # [[Intake fractions of PM]] uses Humbert iF as default. | |||
## Health assessment | |||
# | objects.latest('Op_en2261', code_name = 'totcases') # [[Health impact assessment]] totcases and dependencies. | ||
objects.latest('Op_en5461', code_name = 'DALYs') # [[Climate change policies and health in Kuopio]] DALYs, DW, L | |||
population <- 623732 # Contains only the Helsinki city, i.e. assumes no exposure outside city. (Wikipedia) | |||
## | # Note: the population size does NOT affect the health impact if the exposure-response function in linear. | ||
# However, it DOES affect exposure estimates. | |||
#########################i-------------------------------------------------- | |||
################# Actual model and some intermediate processing. | |||
DecisionTableParser(decisions) | DecisionTableParser(decisions) | ||
Line 226: | Line 218: | ||
forgetDecisions() | forgetDecisions() | ||
renovationRate <- EvalOutput(renovationRate) * 10 # Rates for 10-year periods | |||
buildings <- EvalOutput(buildings) | |||
buildings@output$EnergySavingPolicy <- factor( | |||
buildings@output$EnergySavingPolicy, | |||
levels = c("BAU", "Energy saving moderate", "Energy saving total"), | |||
ordered = TRUE | |||
) | |||
exposure <- EvalOutput(exposure) | |||
exposure@output <- exposure@output[exposure@output$Area == "Average" , ] # Helsinki is an average area, | |||
# rather than rural or urban. | |||
totcases <- EvalOutput(totcases) | |||
totcases@output$Time <- as.numeric(as.character(totcases@output$Time)) | |||
totcases <- oapply(totcases, cols = c("Age", "Sex"), FUN = sum) | |||
totcases <- truncateIndex(totcases, cols = "Heating", bins = 5) | |||
DALYs <- EvalOutput(DALYs) | |||
####################### Post-processing and graphs | |||
bui <- oapply(buildings * 1E-6, cols = c("City_area", "buildingsSource"), FUN = sum) | bui <- oapply(buildings * 1E-6, cols = c("City_area", "buildingsSource"), FUN = sum) | ||
Line 275: | Line 247: | ||
#levels(bui$Heating)[levels(bui$Heating) == "Long-distance heating"] <- "District heating" | #levels(bui$Heating)[levels(bui$Heating) == "Long-distance heating"] <- "District heating" | ||
ggplot(subset(bui, | ggplot(subset(bui, EnergySavingPolicy == "BAU"), aes(x = Time, weight = buildingsResult, fill = Heating)) + geom_bar(binwidth = 5) + | ||
theme_gray(base_size = BS) + | theme_gray(base_size = BS) + | ||
labs( | labs( | ||
Line 285: | Line 257: | ||
if(figstofile) ggsave("Figure6.eps", width = 8, height = 7) | if(figstofile) ggsave("Figure6.eps", width = 8, height = 7) | ||
ggplot( | #ggplot(renovationRate@output, aes(x = Time, weight = renovationRateResult)) + geom_bar(binwidth = 5) + | ||
# facet_grid(. ~ EnergySavingPolicy) + theme_gray(base_size = BS) + | |||
# labs( | |||
# title = "Renovation rate by energy saving policy", | |||
# x = "Time", | |||
# y = "Floor area (M m2)" | |||
# ) | |||
ggplot | ggplot(bui, aes(x = Time, weight = buildingsResult, fill = Efficiency)) + geom_bar(binwidth = 5) + | ||
facet_grid(. ~ | facet_grid(. ~ EnergySavingPolicy) + theme_gray(base_size = BS) + | ||
labs( | labs( | ||
title = "Building stock in Helsinki by efficiency policy", | title = "Building stock in Helsinki by efficiency policy", | ||
Line 301: | Line 273: | ||
) | ) | ||
ggplot | ggplot(bui, aes(x = Time, weight = buildingsResult, fill = Renovation)) + geom_bar(binwidth = 5) + | ||
theme_gray(base_size = BS) + | theme_gray(base_size = BS) + facet_grid(. ~ EnergySavingPolicy) + | ||
labs( | labs( | ||
title = "Building stock in Helsinki", | title = "Building stock in Helsinki", | ||
Line 309: | Line 281: | ||
) | ) | ||
ggplot(subset(bui, | ggplot(subset(bui, EnergySavingPolicy == "BAU"), aes(x = Time, weight = buildingsResult, fill = Building)) + geom_bar(binwidth = 5) + | ||
theme_gray(base_size = BS) + | theme_gray(base_size = BS) + | ||
labs( | labs( | ||
Line 317: | Line 289: | ||
) | ) | ||
emissions@output$Time <- as.numeric(as.character(emissions@output$Time)) | emissions@output$Time <- as.numeric(as.character(emissions@output$Time)) | ||
# Plot energy need and emissions | # Plot energy need and emissions | ||
hea <- oapply( | hea <- oapply(energyUse * 1E-6, cols = c("City_area", "buildingsSource"), FUN = sum) | ||
hea <- truncateIndex(hea, cols = "Heating", bins = 4)@output | hea <- truncateIndex(hea, cols = "Heating", bins = 4)@output | ||
ggplot(hea, aes(x = Time, weight = | ggplot(hea, aes(x = Time, weight = energyUseResult, fill = Heating)) + geom_bar(binwidth = 5) + # Tuplamuunnos *1e-6 pois | ||
facet_wrap( ~ | facet_wrap( ~ EnergySavingPolicy) + theme_gray(base_size = BS) + | ||
labs( | labs( | ||
title = "Energy used in heating in Helsinki", | title = "Energy used in heating in Helsinki", | ||
Line 409: | Line 304: | ||
) | ) | ||
emis <- truncateIndex(emissions, cols = "Emission_site", bins = 5)@output | emis <- truncateIndex(emissions, cols = "Emission_site", bins = 5)@output | ||
ggplot(subset(emis, | ggplot(subset(emis, FuelPolicy == "BAU"), aes(x = Time, weight = emissionsResult, fill = Emission_site)) + geom_bar(binwidth = 5) + | ||
facet_grid(Pollutant ~ EnergySavingPolicy, scale = "free_y") + theme_gray(base_size = BS) + | |||
labs( | |||
title = "Emissions from heating in Helsinki", | |||
x = "Time", | |||
y = "Emissions (ton /a)" | |||
) | |||
ggplot(subset( | ggplot(subset(emissions@output, EnergySavingPolicy == "BAU"), aes(x = Time, weight = emissionsResult, fill = Fuel)) + geom_bar(binwidth = 5) + | ||
facet_grid(Pollutant ~ FuelPolicy, scale = "free_y") + theme_gray(base_size = BS) + | facet_grid(Pollutant ~ FuelPolicy, scale = "free_y") + theme_gray(base_size = BS) + | ||
labs( | labs( | ||
Line 427: | Line 322: | ||
) | ) | ||
ggplot(subset( | #ggplot(subset(emissions@output, EnergySavingPolicy == "BAU" & FuelPolicy == "BAU"), aes(x = Time, weight = emissionsResult, fill = Fuel)) + geom_bar(binwidth = 5) + | ||
# facet_grid(Pollutant ~ . , scale = "free_y") + theme_gray(base_size = BS) + | |||
# labs( | |||
# title = "Emissions from heating in Helsinki", | |||
# x = "Time", | |||
# y = "Emissions (ton /a)" | |||
# ) | |||
ggplot(exposure@output, aes(x = Time, weight = exposureResult, fill = Heating)) + geom_bar(binwidth = 5) + | |||
facet_grid(EnergySavingPolicy ~ FuelPolicy) + theme_gray(base_size = BS) + | |||
ggplot | |||
labs( | labs( | ||
title = "Exposure to PM2.5 from heating in Helsinki", | title = "Exposure to PM2.5 from heating in Helsinki", | ||
Line 467: | Line 338: | ||
) | ) | ||
ggplot(exposure@output, aes(x = Time, weight = exposureResult, fill = Fuel)) + geom_bar(binwidth = 5) + | |||
facet_grid(EnergySavingPolicy ~ FuelPolicy) + theme_gray(base_size = BS) + | |||
ggplot | |||
labs( | labs( | ||
title = "Exposure to PM2.5 from heating in Helsinki", | title = "Exposure to PM2.5 from heating in Helsinki", | ||
Line 477: | Line 346: | ||
) | ) | ||
ggplot(subset(totcases@output, FuelPolicy == "BAU"), aes(x = Time, weight = totcasesResult, fill = Heating))+geom_bar(binwidth = 5) + | |||
facet_grid(Response ~ EnergySavingPolicy) + | |||
ggplot(subset(totcases@output, | |||
facet_grid( | |||
theme_gray(base_size = BS) + | theme_gray(base_size = BS) + | ||
labs( | labs( | ||
Line 494: | Line 356: | ||
if(figstofile) ggsave("Figure8.eps", width = 11, height = 7) | if(figstofile) ggsave("Figure8.eps", width = 11, height = 7) | ||
cat("Total DALYs/a by different combinations of policy options.\n") | cat("Total DALYs/a by different combinations of policy options.\n") | ||
Line 505: | Line 362: | ||
temp@output <- subset( | temp@output <- subset( | ||
temp@output, | temp@output, | ||
as.character(Time) %in% c("2010", "2030") & | as.character(Time) %in% c("2010", "2030") & Response == "Total mortality" | ||
) | ) | ||
oprint(oapply(temp, INDEX = c("Time", " | oprint( | ||
oapply(temp, INDEX = c("Time", "EnergySavingPolicy", "FuelPolicy"), FUN = sum), | |||
caption = "Table 1: Total DALYs/a by different combinations of policy options.", | |||
caption.placement = "top", | |||
include.rownames = FALSE | |||
) | |||
ggplot(subset(DALYs@output, | ggplot(subset(DALYs@output, Response == "Total mortality"), aes(x = Time, weight = DALYsResult, fill = Heating))+geom_bar(binwidth = 5) + | ||
facet_grid( | facet_grid(EnergySavingPolicy ~ FuelPolicy) + | ||
theme_gray(base_size = BS) + | theme_gray(base_size = BS) + | ||
labs( | labs( | ||
Line 519: | Line 381: | ||
) | ) | ||
ggplot(subset(DALYs@output, Time == 2030 | ggplot(subset(DALYs@output, Time == 2030), aes(x = FuelPolicy, weight = DALYsResult, fill = Heating))+geom_bar() + | ||
facet_grid( | facet_grid(EnergySavingPolicy ~ Response) + | ||
theme_gray(base_size = BS) + | theme_gray(base_size = BS) + | ||
labs( | labs( | ||
Line 528: | Line 390: | ||
) | ) | ||
koord <- | koord <- opbase.data("Op_en7115", subset = "Locations of city areas") | ||
colnames(koord) <- | koord <- tidy(koord, widecol = "Location") | ||
colnames(koord)[colnames(koord) == "City_area"] <- "Emission_site" | |||
#colnames(koord)[colnames(koord) == "N"] <- "X" | |||
#colnames(koord)[colnames(koord) == "E"] <- "Y" | |||
koord$Result <- 1 | koord$Result <- 1 | ||
koord <- Ovariable("koord", output = koord, marginal = | koord <- Ovariable("koord", output = koord, marginal = colnames(koord) != "Result") | ||
emis <- emissions * koord | emis <- emissions * koord | ||
emis@output <- subset(emis@output, | emis@output <- subset(emis@output, EnergySavingPolicy == "BAU" & | ||
emis <- oapply(emis, INDEX = c("Emission_site", " | FuelPolicy == "BAU" & Pollutant == "PM2.5") | ||
emis <- oapply(emis, INDEX = c("Emission_site", "N", "E"), FUN = sum) | |||
MyRmap( | MyRmap( | ||
ova2spat( | |||
emis, | |||
coord = c("E", "N"), | |||
proj4string = "+init=epsg:3067" | |||
), # National Land Survey Finland uses ETRS89 / ETRS-TM35FIN | |||
#http://spatialreference.org/ref/epsg/etrs89-etrs-tm35fin/ | |||
plotvar = "Result", | |||
legend_title = "PM2.5 emissions (ton/a)", | |||
numbins = 4, | |||
pch = 19, | |||
cex = sqrt(result(emis)) * 3 | |||
) | ) | ||
# Map saved manually to .eps with width = 1280, height = 960 px. | # Map saved manually to .eps with width = 1280, height = 960 px. | ||
</rcode> | </rcode> | ||
{{attack|# |In the results the graph "Energy used in heating in Helsinki" shows a twice or thrice bigger energy use for Oil and Other than the table "Total energy consumption in Helsinki in 2013 (GWh)" on [[Helsinki energy consumption]] would suggest.|--[[User:Heta|Heta]] ([[User talk:Heta|talk]]) 08:18, 11 June 2015 (UTC)}} | |||
{{attack|# |Effective floor area of buildings by building type -table on page [[Building stock in Helsinki]] has the current building stock at 7 million m2 more than the graphs in the result, and the future estimates are even more higher than the code result estimates|--[[User:Heta|Heta]] ([[User talk:Heta|talk]]) 10:49, 11 June 2015 (UTC)}} | |||
== See also == | == See also == | ||
;Other related assessments | ;Other related assessments | ||
{{Helsinki energy decision 2015}} | |||
* [[Climate change policies and health in Kuopio]] | * [[Climate change policies and health in Kuopio]] | ||
* [[Climate change policies in Basel]] | * [[Climate change policies in Basel]] | ||
* [[Climate change policies in Kuopio]] | * [[Climate change policies in Kuopio]] | ||
* [http://www.hri.fi/fi/dataset?sort=metadata_created+desc&q= Helsinki Region Infoshare] | * [http://www.hri.fi/fi/dataset?sort=metadata_created+desc&q= Helsinki Region Infoshare] | ||
=== Other variables and pages to look at === | === Other variables and pages to look at === | ||
Line 577: | Line 451: | ||
* {{#l:Housing stock in Helsinki metropolitan area.xls}} | * {{#l:Housing stock in Helsinki metropolitan area.xls}} | ||
* {{#l:Parameters, gabi-model.xls}} | * {{#l:Parameters, gabi-model.xls}} | ||
* [[Gabi 4.3 - life cycle assessment software]] | * [[Gabi 4.3 - life cycle assessment software]] | ||
* [http://energiaremontti2015.fi/mika-energiaremontti/ Energiaremontti] | |||
* [http://urn.fi/URN:NBN:fi:jyu-201402281297 Halme et al. 2014 Kasvua ja työllisyyttä uudella energiapolitiikalla] | |||
* [https://www.facebook.com/energiaremontti2015.fi?ref=br_rs Energiaremontti 2015] -Facebook-ryhmä | |||
* [https://www.facebook.com/groups/740342559331216/ Uusi energiapolitiikka] -Facebook-sivu | |||
* Helsingin Sanomat: [http://www.hs.fi/kaupunki/a1434082462141 Energiavallankumous horjuttaa Helsingin jättivoimalahanketta – miljardin euron päätöstä saatetaan lykätä jälleen] | |||
;Possibly useful variables | ;Possibly useful variables |
Latest revision as of 16:53, 11 January 2016
Moderator:Jouni (see all) |
|
Upload data
|
- This assessment was used for training in Decision analysis and risk management 2015 course. To see student contributions, see a previous version.
Scope
Question
What is the energy need of buildings in Helsinki and the related greenhouse gas emissions and health impacts? How can these be affected by renovation of buildings and fuel changes in district heating?
Intended use and users
A problem in the climate policy practices in the City of Helsinki is that there is not enough information about different costs and impacts of different climate change mitigation measures, especially in the long term. This is slowing down the decision-making process. The results of this course will be used at the City of Helsinki Environment Centre to assess the outcomes of different ways to reduce GHG emissions. The results will help in identifying the most favourable ways to cut GHG emissions.
Participants
- Jouni Tuomisto (THL), the coordinator of the assessment
- The participants of the Decision analysis and risk management 2015 course.
- Helsinki Environment Centre
- Siemens and the City Performance Tool experts
Boundaries
- Time: 2010-2060
- Spatial: the city of Helsinki
Decisions and scenarios
Energy saving policy: Relates to the shares of efficiency types when new buildings are built (ovariable efficiencyShares).
- BAU: Business as usual, no change to the energy efficiency of buildings.
- Energy saving moderate: No change to the energy efficiency of buildings.
- Energy saving total: Starting from the year 2020 buildings are built to be more energy efficient. 25 percentage points of production shifts from low-energy buildings to passive buildings. Starting from the year 2040 another 10 percentage points of production shifts from low-energy to passive.
Fuel policy: Helen increases the share of wood-based biofuels used in Hanasaari and Salmisaari power plants to 40 % of fuels used. Both burn 40 % wood pellets and 60 % coal. (ovariable fuelShares)
- BAU: Business and usual, both power plants continue burning only 5-10 % biofuel.
- 40 bio: Shift to biofuels, starting from the year 2020 the share of wood-based fuels increase by 24 percentage points and coal's share decrease by the same amount.
Energy saving policy (ovariable renovationRate)
- BAU: Business as usual, every year 1 % of all buildings over 30 years old are renovated to increase their energy efficiency.
- Energy saving moderate: Increased energy renovation, every year 2 % of all buildings over 30 years old are renovated to increase their energy efficiency.
- Energy saving total: Greatly increased energy renovation, every year 3 % of all buildings over 30 years old are renovated to increase their energy efficiency.
See also decisions in Climate change policies and health in Kuopio.
Show details | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Timing
The data will be collected before the end of the Decision analysis and risk management 2015 course (12th May, 2015). The model runs will be finalised soon after that. Results will be available before September 2015.
Answer
Results
Conclusions
Rationale
Stakeholders
- City of Helsinki
Dependencies
- Building stock in Helsinki
- Energy use of buildings
- Emission factors for burning processes
- Climate change policies and health in Kuopio#Direct inputs
- District heating production units in Helsinki metropolitan area
- Exposure to PM2.5 in Finland
- OpasnetUtils/Drafts
- Health impact assessment
- Disease risk
- Exposure-response function
- Burden of disease in Finland
- Outdoor air temperature in Finland
- Unit price of carbon emission permits
- Data files
- Climate policies Helsinki data
- Climate policies Helsinki additional data
- Helsingin_rakennuskanta_Facta_ajo_huhtikuu_2015
- Additional sources of information (may be useful)
- Motiva, Sami Seuna [1]
- Tilastokeskus Jonna Hakala 09 1734 3419, energia@tilastokeskus.fi [2]
- VTT: Energy efficiency scenarios of buildings (2014) [3]
- VTT energy efficiency expert Jyri Nieminen
- Tampere University of Technology: EPAT: Energy saving potential in Finnish housing stock by 2050. [4] See especially section 4.2.4.
Discussions
These are some resolutions of discussions within the assessment.
- City level climate change mitigation is not useless although international treaties are important for success.D↷
- Climate change adaptation is not more important than mitigation on city level.R↻
- Citizens may have a key role in implementing city climate policies.D↷
- Food issues are underrepresented in climate discussions although food is a major emission source.R↻
- The role of district heating by nuclear energy in Helsinki is unclear.D↷
- There may be large uncertainty in CO2 emission factors of biofuels.D↷
Analyses
Indices
The data will be classified according to these indices:
- Building: Residential, Public, Industrial, Other. For separating different use purposes of buildings.
- Constructed: Years of construction of the buildings in the format 1990-1999, 2000-2009, 2010-2013.
- Heating: District, Electricity, Geothermal, Oil, Wood,
The results of each ovariable will be measuring these things:
- buildings: total floor area in m2.
Calculations
- Model run 15.6.2015
- Model run 24.6.2015 (new structure of building model)
⇤--#: . In the results the graph "Energy used in heating in Helsinki" shows a twice or thrice bigger energy use for Oil and Other than the table "Total energy consumption in Helsinki in 2013 (GWh)" on Helsinki energy consumption would suggest. --Heta (talk) 08:18, 11 June 2015 (UTC) (type: truth; paradigms: science: attack)
⇤--#: . Effective floor area of buildings by building type -table on page Building stock in Helsinki has the current building stock at 7 million m2 more than the graphs in the result, and the future estimates are even more higher than the code result estimates --Heta (talk) 10:49, 11 June 2015 (UTC) (type: truth; paradigms: science: attack)
See also
- Other related assessments
- Climate change policies and health in Kuopio
- Climate change policies in Basel
- Climate change policies in Kuopio
- Helsinki Region Infoshare
Other variables and pages to look at
- Thermal energy need in Helsinki Metropolitan Area
- Heating consumption of buildings
- Emission assessment of small-scale energy production in the Helsinki metropolitan area
- CLAIH assessment
- BIOHER assessment
- Unit heat consumption of buildings in Finland
- Assessment of small-scale energy production in Helsinki Metropolitan area
- Bioher model
- Claih model
- Housing stock in Helsinki metropolitan area
- Parameters, gabi-model
- Gabi 4.3 - life cycle assessment software
- Energiaremontti
- Halme et al. 2014 Kasvua ja työllisyyttä uudella energiapolitiikalla
- Energiaremontti 2015 -Facebook-ryhmä
- Uusi energiapolitiikka -Facebook-sivu
- Helsingin Sanomat: Energiavallankumous horjuttaa Helsingin jättivoimalahanketta – miljardin euron päätöstä saatetaan lykätä jälleen
- Possibly useful variables
- Assessment on impacts of emission trading on city-level (ET-CL)
- Exposure of Finnish subpopulations to fine particles due domestic wood combustion
- Prices of fuels in heat production
- Heating consumption of buildings
- Value of a life year (VOLY)
- Unit price of energy in residential heating in Finland
- Unit value of restricted activity days (RADs)
- Unit value of hospital admissions
- Value of a statistical life (VSL)
- Duration of morbidity
- Disability weights
- Morbidity in Finland LOOK AT THE ANALYTICA FILE
- Mortality in Finland
- Population of Finland
- Asthma prevalence
- Breathing rate
- Mortality in Finland
- Electricity production in Finland
- District heat production in Finland
- heande:HI:Policy for PM2.5 Exposure (ASK LAMA IF THIS CAN BE RELEASED!
- ERF for cold exposure and mortality
- ERF for heat exposure and morbidity
- ERF of ambient temperature on mortality
- ERF of indoor dampness on respiratory health effects
- Exposure to dampness and mold contamination in homes in Finland
- ERF for short term PM10 exposure and lower respiratory symptoms (LRS)
- ERF for short term PM10 exposure and medication usage by people with asthma
- ERF for short term PM2.5 exposure and minor restricted activity days (MRADs)
- ERF for short term PM2.5 exposure and work loss days (WLDs)
- ERF for short term PM2.5 exposure and restricted activity days (RADs)
- ERF for short term PM10 exposure and respiratory hospital admissions
- ERF for short-term PM10 exposure and cardiovascular hospital admissions
- Concentration-response to PM2.5 THIS IS THE NEWEST but many pages should be merged with this. RENAME?
- Exposure to PM2.5 in Finland
- PM 2.5 concentration indoors from indoor sources in Finland THIS IS A METHOD
- PM infiltration from outdoor air to indoor air THIS IS A METHOD
- N2O emissions from house stock heating in Finland
- CH4 emissions from house stock heating in Finland
- CO2 emissions from house stock heating in Finland
- Unit heat consumption of buildings in Finland
- Energy efficiency of buildings in Finland THIS IS ACTUALLY BUILDING STOCK OF FINLAND
- Heating systems in buildings in Finland SHOULD BE UPDATED FROM STAT FINLAND IF NEEDED
- Almost empty pages that should be removed
- Unit price of carbon emission permits
- Outdoor air temperature in Finland
- PM2.5 concentration in Finland
- PM2.5 emissions from house stock heating in Finland
- New house stock production in Finland
Keywords
Helsinki, energy, building stock, heating, renovation.
References