ERF of indoor dampness on respiratory health effects: Difference between revisions
No edit summary |
|||
Line 105: | Line 105: | ||
[[OR]] per yes/no visible dampness and/or mold or mold odor | [[OR]] per yes/no visible dampness and/or mold or mold odor | ||
=== | === Calculations === | ||
*Generates random samples of possible [[OR]]s. | *Generates random samples of possible [[OR]]s. |
Revision as of 09:16, 24 January 2013
Moderator:Ulla H-S (see all) |
|
Upload data
|
Question
What is the association between exposure to indoor dampness and mould in homes and respiratory health effects?
Answer
Exposure-response function
Obs | Disease | Response metric | Subjects | Exposure route | Exposure metric | Exposure unit | ERF parameter | Threshold | ERF | Description |
---|---|---|---|---|---|---|---|---|---|---|
1 | Respiratory health effect | Upper respiratory tract symptoms | All | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.70 | 1.70 (1.44-2.00), No. studies: 13 |
2 | Respiratory health effect | Cough | All | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.67 | 1.67 (1.49-1.86), No. studies: 18 |
3 | Respiratory health effect | Cough | Adults | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.52 | 1.52 (1.18-1.96), No. studies: 6 |
4 | Respiratory health effect | Cough | Children | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.75 | 1.75 (1.56-1.96), No. studies: 6 |
5 | Respiratory health effect | Wheeze | All | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.50 | 1.50 (1.38-1.64), No. studies: 22 |
6 | Respiratory health effect | Wheeze | Adults | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.39 | 1.39 (1.04-1.85), No. studies: 5 |
7 | Respiratory health effect | Wheeze | Children | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.53 | 1.53 (1.39-1.68), No. studies: 17 |
8 | Respiratory health effect | Current asthma | All | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.56 | 1.56 (1.30-1.86), No. studies: 10 |
9 | Respiratory health effect | Ever-diagnosed asthma | All | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.37 | 1.37 (1.23-1.53), No. studies: 8 |
10 | Respiratory health effect | Ever-diagnosed asthma | Children | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.35 | 1.35 (1.20-1.51), No. studies: - |
11 | Respiratory health effect | Asthma development | All | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.34 | 1.34 (0.86-2.10), No. studies: 4 |
12 | Respiratory health effect | Bronchitis | All | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.45 | 1.45 (1.32-1.59), No. studies: - |
13 | Respiratory health effect | Bronchitis | Children | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.38 | 1.38 (1.28-1.47), No. studies: - |
14 | Respiratory health effect | Respiratory infections | All | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.44 | 1.44 (1.31-1.59), No. studies: - |
15 | Respiratory health effect | Respiratory infections | Adults | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.49 | 1.49 (1.14-1.95), No. studies: - |
16 | Respiratory health effect | Respiratory infections | Children | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.48 | 1.48 (1.33-1.65), No. studies: - |
17 | Respiratory health effect | Sensitivity to inhaled antigens | Children | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.33 | 1.33 (1.23-1.44), No. studies: - |
18 | Respiratory health effect | Hay fever | Children | Inhalation | visible dampness and/or mold or mold odor | yes/no | OR | 0 | 1.35 | 1.35 (1.18-1.53), No. studies: - |
Page-specific entries (indices that have exactly one value each for the whole variable; usually mentioned in the title and/or in the scope.):
- Pollutant: visible dampness and/or mold or mold odor
- Threshold: 0
- Exposure metric: yes/no
- Exposure route: Inhalation
----#: . You can leave the columns listed above out of the table, because all rows have the same value. If you do, then you MUST put the respective information to Category:Exposure-response functions. --Jouni 17:38, 23 January 2012 (EET) (type: truth; paradigms: science: comment)
⇤--#: . If possible, "Disease" should be something that has an ICT-10 code (in this case, the information that is in column "Response metric". In contrast, "Response metric" should describe how the disease was measured: number of cases, incidence, prevalence,... --Jouni 17:38, 23 January 2012 (EET) (type: truth; paradigms: science: attack)
Rationale
Data
Outcome | Subjects | No. studies | Odds ratio central estimate (95 % CI) | Estimated % increase in damp homes |
---|---|---|---|---|
Upper respiratory tract symptoms | All | 13 | 1.70 (1.44–2.00) | 52 |
Cough | All | 18 | 1.67 (1.49–1.86) | 50 |
Adults | 6 | 1.52 (1.18–1.96) | – | |
Children | 12 | 1.75 (1.56–1.96) | – | |
Wheeze | All | 22 | 1.50 (1.38–1.64) | 44 |
Adults | 5 | 1.39 (1.04–1.85) | – | |
Children | 17 | 1.53 (1.39–1.68) | – | |
Current asthma | All | 10 | 1.56 (1.30–1.86) | 50 |
Ever-diagnosed asthma | All | 8 | 1.37 (1.23–1.53) | 33 |
Children | 1.35 (1.20–1.51) | |||
Asthma development | All | 4 | 1.34 (0.86–2.10) | 30 |
Bronchitis | All | 1.45 (1.32–1.59) | ||
Children | 1.38 (1.28–1.47) | |||
Respiratory infections | All | 1.44 (1.31–1.59) | ||
Adults | 1.49 (1.14–1.95) | |||
Children | 1.48 (1.33–1.65) | |||
Sensitivity to inhaled antigens | Children | 1.33 (1.23–1.44) | ||
Hay fever | Children | 1.35 (1.18–1.53) |
Dependencies
Unit
OR per yes/no visible dampness and/or mold or mold odor
Calculations
- Generates random samples of possible ORs.
- Normal distribution assumed, sd estimated from confidence interval using sd = (upper bound - lower bound)/3.92
See also
Keywords
References
- ↑ W. J. Fisk, Q. Lei-Gomez, M. J. Mendell. Meta-analyses of the associations of respiratory health effects with dampness and mold in homes. Indoor Air 2007; 17: 284–296. doi:10.1111/j.1600-0668.2007.00475.x
- ↑ Mendell et al. 2011. Respiratory and allergic health effects of dampness and mold, and dampness-related agents: a review of the epidemiological evidence. Environmental Health Perspectives 119(6), 748-756.
Related files
<mfanonymousfilelist></mfanonymousfilelist>