Helsinki energy production
[show] |
---|
Question
What is the amount of energy produced (including distributed production) in Helsinki? Where is it produced (-> emissions)? Which processes are used in its production?
Answer
Rationale
Energy balance
Amount produced is determined largely by the energy balance in Helsinki and Helsinki energy consumption. Energy produced and fuels used by of all Helen's power plants.[1]
Obs | Plant | Burner | Electricity | Heat | Cooling | Coal | Gas | Fuel oil | Biofuel | Description |
---|---|---|---|---|---|---|---|---|---|---|
1 | Hanasaari | Large fluidized bed | 0.31 | 0.60 | 0 | -1 | 0 | 0 | 0 | Assume 91 % efficiency. Capacity: electricity 220 MW heat 420 MW Loss 64 MW |
2 | Hanasaari biofuel renovation | Large fluidized bed | 0.31 | 0.60 | 0 | -0.6 | 0 | 0 | -0.4 | |
3 | Vuosaari A&B | Large fluidized bed | 0.47 | 0.44 | 0 | 0 | -1 | 0 | 0 | Capacity: electricity 630 MW heat 580 MW loss 121 MW |
4 | Vuosaari C biofuel | Large fluidized bed | 0.47 | 0.44 | 0 | 0 | 0 | 0 | -1 | |
5 | Salmisaari A&B | Large fluidized bed | 0.32 | 0.59 | 0 | -1 | 0 | 0 | 0 | Capacity: electricity 160 MW heat 300 MW loss 46 MW |
6 | Salmisaari biofuel renovation | Large fluidized bed | 0.32 | 0.59 | 0 | 0 | 0 | 0 | -1 | |
7 | Smaller gas heat plants around Helsinki | Large fluidized bed | 0 | 0.91 | 0 | 0 | -1 | 0 | 0 | |
8 | Smaller fuel oil heat plants around Helsinki | Large fluidized bed | 0 | 0.91 | 0 | 0 | 0 | -1 | 0 | |
9 | Katri Vala heat | None | -0.35 | 1 | 0 | 0 | 0 | 0 | 0 | Heat from cleaned waste water and district heating network's returing water. |
10 | Katri Vala cooling | None | -0.55 | 0 | 1 | 0 | 0 | 0 | 0 | District cooling produced by absorption (?) heat pumps. |
11 | Kymijoki River's plants | None | 1 | 0 | 0 | 0 | 0 | 0 | 0 | Hydropower |
12 | Powerplant museum in Vanhakaupunki | None | 1 | 0 | 0 | 0 | 0 | 0 | 0 | Hydropower |
13 | Kellosaari back-up plant | Large fluidized bed | 0.35 | 0 | 0 | 0 | 0 | -1 | 0 | |
14 | Suvilahti power storage | None | 1 | 0 | 0 | 0 | 0 | 0 | 0 | |
15 | Loviisa nuclear heat | None | -0.1 | 1 | 0 | 0 | 0 | 0 | 0 | |
16 | Neste oil refinery heat | None | -0.1 | 1 | 0 | 0 | 0 | 0 | 0 | |
17 | Household heat pumps | None | -0.2 - -0,7 | 1 | 0 | 0 | 0 | 0 | 0 | The efficiency of heat pumps is largely dependent on outside air temperature, it's feasible for a household heat pump to reach COP 5 at 10 °C and COP 1.5 at -25 °C. |
18 | Deep-drill heat | None | -0.1 | 1 | 0 | 0 | 0 | 0 | 0 | |
19 | Sea heat pump | None | -0.2 | 1 | 0 | 0 | 0 | 0 | 0 | |
20 | Small-scale wood burning | Domestic | 0 | 0.5 - 0.9 | 0 | 0 | 0 | 0 | -1 | |
21 | Air conditioning | None | -0.2 - -0.7 | 0 | 1 | 0 | 0 | 0 | 0 | Household air conditioning units range from EER 5 to EER 18, depending on age. |
22 | CHP diesel generators | Diesel engine | 0.3 | 0.4 | 0 | 0 | 0 | -1 | 0 |
Notes:
- Household heat pump comparison[2]
- Loss of thermal energy through distribution is around 10 %. From Norwegian Water Resources and Energy Directorate: Energy in Norway.[3]
- Sustainable Energy Technology at Work: Use of waste heat from refining industry, Sweden.[4]
- Chalmers University of Technology: Towards a Sustainable Oil Refinery, Pre-study for larger co-operation projects[5]
- Energy Department of the United States: Geothermal Heat Pumps[6]
- Energy Department of the United States: Wood and Pellet Heating[7]
- Energy Department of the United States: Central Air Conditioning[8]
Obs | Year | Plant | Min | Max | Investment cost | Management cost | Operation cost | Description |
---|---|---|---|---|---|---|---|---|
1 | 2015 | Hanasaari | 0 | 640 | 338 | 10 | 4 | 95% coal, 5% pellets |
2 | 2015 | Hanasaari biofuel renovation | 0 | 640 | 100 | 10 | 4 | 60% coal, 40% biofuels |
3 | 2015 | Vuosaari A&B | 0 | 1331 | 600-650 | 10 | 5 | natural gas |
4 | 2015 | Vuosaari C biofuel | 0 | 1331 | 650 | 10 | 5 | 80-100% biofuels, rest coal |
5 | 2015 | Salmisaari A&B | 0 | 506 | 100 | 10 | 4 | 95% coal, 5% pellets |
6 | 2015 | Salmisaari biofuel renovation | 0 | 506 | 100 | 10 | 4 | 60% coal, 40% biofuels |
7 | 2015 | Smaller heat plants around Helsinki | 0 | 2015 | 100 | 10 | 10 | |
8 | 2015 | Katri Vala heat | 0 | 90 | 100 | 10 | 3 | waste water |
9 | 2015 | Katri Vala cooling | 0 | 60 | 100 | 10 | 3 | waste water |
10 | 2015 | Kymijoki River's plants | 0 | 60 | 100 | 10 | 10 | water |
11 | 2015 | Powerplant museum in Vanhakaupunki | 0 | 0.2 | 100 | 10 | 0 | water |
12 | 2015 | Kellosaari back-up plant | 0 | 120 | 100 | 10 | 20 | oil |
13 | 2015 | Suvilahti solar | 0 | 0.34 | 0.6 | 10 | 5 | |
14 | 2015 | Suvilahti power storage | -1.2 | 1.2 | 100 | 10 | 5 | electricity storage 0.6 MWh |
15 | 2015 | Wind mills | 0 | 4 | 100 | 10 | 5 | |
16 | 2015 | Loviisa nuclear heat | 0 | 3000 | 100 | 10 | 5 | |
17 | 2015 | Neste oil refinery heat | 0 | 2000 | 100 | 10 | 5 | |
18 | 2015 | Household heat pumps | 0 | 300 | 100 | 10 | 5 | |
19 | 2015 | Deep-drill heat | 0 | 500 | 100 | 10 | 7 | |
20 | 2015 | Sea heat pump | 0 | 500 | 100 | 10 | 4 | |
21 | 2015 | Small-scale wood burning | 0 | 500 | 100 | 10 | 5 | |
22 | 2015 | Air conditioning | 0 | 500 | 100 | 10 | 5 | |
23 | 2015 | CHP diesel generators | 0 | 500 | 100 | 10 | 5 |
Notes:
- Helens’s windpower [9]
- Suvilahti solar [10]
- Loviisan sanomat: Loviisan ydinvoimalan tehoja aiotaan nostaa 52 megawattia. [11]
Obs | Plant | Fuel | 2015 | 2020 | 2030 | 2040 | 2050 | 2060 |
---|---|---|---|---|---|---|---|---|
1 | Suvilahti solar | Electricity | 0 | 0 | 0 | 0 | 0 | 0 |
2 | Wind mills | Electricity | 0 | 0 | 0 | 0 | 0 | 0 |
⇤--#: . How to model non-adjustable energy production exactly? Probably needs a submodel instead of a t2b table. --Jouni (talk) 07:30, 27 June 2015 (UTC) (type: truth; paradigms: science: attack)
----#: . Should air conditioning be in process matrix or in non-adjustable energy production? --Jouni (talk) 07:30, 27 June 2015 (UTC) (type: truth; paradigms: science: comment)
These equations aim to reflect the energy production facilities and capabilities.
Note! Maintenance cost only contains costs that do not depend on activity. Operational cost contains costs that depend on activity but NOT fuel costs; those are calculated separately based on energy produced.
Heating
Fuel use by heating type
Only district heating is Helsinki specific, rest should be taken from Emission factors for burning processes.
Obs | Heating | Burner | Fuel | Fraction | Description |
---|---|---|---|---|---|
1 | District | Large fluidized bed | Coal | 0.6 | |
2 | District | Large fluidized bed | Gas | 0.4 | |
3 | District | Large fluidized bed | Wood | 0 |
Emission locations
Emission location and height by heating type.
Obs | Heating | Emission_site | Emission_height | Dummy |
---|---|---|---|---|
1 | District | 010 | High | |
2 | Electricity | 010 | High | |
3 | Geothermal | 010 | High | |
4 | Oil | At site of consumption | Ground | |
5 | Wood | At site of consumption | Ground | |
6 | Gas | At site of consumption | Ground | |
7 | Coal | At site of consumption | Ground |
This code creates technical ovariables emissionLocations and heatingShares that are needed to run the Building model and its ovariables buildings and heatingEnergy.
Emission locations per plant
Obs | Plant | Emission site | Emission height | Description |
---|---|---|---|---|
1 | Hanasaari | 010 | High | |
2 | Hanasaari biofuel renovation | 010 | High | |
3 | Vuosaari A&B | 010 | High | |
4 | Vuosaari C biofuel | 010 | High | |
5 | Salmisaari A&B | 010 | High | |
6 | Salmisaari biofuel renovation | 010 | High | |
7 | Smaller heat plants around Helsinki | 010 | Low | |
8 | Katri Vala heat | 010 | ||
9 | Katri Vala cooling | 010 | ||
10 | Kymijoki River's plants | 010 | ||
11 | Powerplant museum in Vanhakaupunki | 010 | ||
12 | Kellosaari back-up plant | 010 | High | |
13 | Suvilahti solar | 010 | ||
14 | Suvilahti power storage | 010 | ||
15 | Wind mills | 010 | ||
16 | Loviisa nuclear heat | 010 | ||
17 | Neste oil refinery heat | 010 | High | |
18 | Household heat pumps | 010 | ||
19 | Deep-drill heat | 010 | ||
20 | Sea heat pump | 010 | ||
21 | Small-scale wood burning | 010 | Ground | |
22 | Air conditioning | 010 | ||
23 | CHP diesel generators | 010 | Ground |
Production and emission statistics
Electricity | 7145 |
District heat and steam | 6807 |
District cooling | 116 |
Dependencies
Calculations
See also
- The model for small-scale energy production in Helsinki Metropolitan area is made by Gabi 4.3 - life cycle assessment software. It is a versatile program which can be used for life cycle assessment, cost analysis, efficiency analysis, Global Reporting Initiative-reports (GRI) and companies annual reports.
- Pohjoismaiden suurin sähkövarasto nousee Helsinkiin - toimintaperiaate kuin kännykän akulla YLE 23.6.2015
Keywords
References
- ↑ Helen: Power plants
- ↑ http://www.scanoffice.fi/fi/tuotteet/tuoteryhmat/ilmalampopumput/raportit-ja-sertifikaatit/vttn-testiraportit
- ↑ http://www.nve.no/global/energi/analyser/energi%20i%20norge%20folder/energy%20in%20norway%202009%20edition.pdf
- ↑ http://www.setatwork.eu/database/products/R179.htm
- ↑ http://publications.lib.chalmers.se/records/fulltext/69752.pdf
- ↑ http://energy.gov/energysaver/articles/geothermal-heat-pumps
- ↑ http://energy.gov/energysaver/articles/wood-and-pellet-heating
- ↑ http://energy.gov/energysaver/articles/central-air-conditioning
- ↑ https://www.helen.fi/kotitalouksille/neuvoa-ja-tietoa/vastuullisuus/hiilineutraali-tulevaisuus/lisaa-tuulivoimaa/
- ↑ https://www.helen.fi/uutiset/2015/aurinkovoiman-tuotanto-on-kaynnistynyt-helsingin-suvilahdessa/
- ↑ http://www.loviisansanomat.net/lue.php?id=5361
- ↑ Helsingin ympäristötilasto