Building stock in Helsinki
Moderator:Jouni (see all) |
|
Upload data
|
Question
What is the building stock in Helsinki?
Important reminder: Always include the references to the tables: where did you get the value and how. A value without the reference is useless because it's not possible for others to track how it was derived.
If you couldn't find a value, write down where you tried to search. This is important because then nobody else needs to search the same sources again for nothing. Thank you!
Answer
Rationale
Data
----#: . CHECK ALSO THIS DATA: --Jouni (talk) 12:53, 5 May 2015 (UTC) (type: truth; paradigms: science: comment)
- Unit heat consumption of buildings in Finland
- http://era17.fi/wp-content/uploads/2010/10/sitran_selvityksia_39.pdf page 25
- http://www.teeparannus.fi/attachements/2010-12-21T11-54-1114846.pdf pages 8-9, also 40-45
- http://www.vtt.fi/inf/pdf/tiedotteet/2007/T2377.pdf page 20-21, also 30, 80
- Heating consumption of buildings
Building stock
The structures of the tables are based on CyPT Excel file N:\YMAL\Projects\ilmastotiekartta\Helsinki Data Input Template - Building Data.xlsx.
Table 1. Effective floor area of buildings by building type.
Type of data:
- Average, City
- Example, city
- Average, city close by
- Example, city close by
- Average, national
- Example, country
Quality of data
- Statistics
- Extrapolated
- Calculated from statistics
- Calculated from stat. inc. assumptions
Obs | Building | Baseline | 2020 | 2025 | 2050 | Year of baseline | Type of data | Quality | Description |
---|---|---|---|---|---|---|---|---|---|
1 | Residential | 27884795 | 30506708 | 32778199 | 41402191 | 2014 | Building block of Helsinki area, 2014 | ||
2 | Public | 4537025 | 4837699 | 5021964 | 5855546 | 2014 | Building block of Helsinki area, 2014 | ||
3 | Industrial | 3277271 | 3338118 | 3393049 | 3676155 | 2014 | Building block of Helsinki area, 2014 | ||
4 | Other | 10861972 | 11581809 | 12022954 | 14018610 | 2014 | Building block of Helsinki area, 2014 |
Ref. Helsinki master plan for 2050: there are 860 000 citizens living in Helsinki (ref. www.yleiskaava.fi, visio2050); Residental buildings => fast growth Prediction of citizen number in Helsinki in 2020, 2030, 2040 and 2050 was used for calculations (ref. Helsingin 30% päästövähennysselvitys). Helsinki’s climate policy: 30% reduction in emissions: In 2010 the proportion of jobs in services and public sectors was 94%, and in industry 6%. In 2020 the proportion of jobs in services and public sectors is estimated to be 96%, and in industry 4%. Public and other buildings => between fast growth option and basic option, Industry=> Basic option Prediction of job number in Helsinki in 2020, 2030, 2040 and 2050 was used for calculations (ref. Helsingin 30% päästövähennysselvitys).
- Notes
- Sheet 4_Input Buildings (Area Demand). Priority 1. Auxiliaries PPT. Absolute increase/decrease rate will be based on the inhabitants projected in time.
- This is another list that was considered but rejected as too complex: Residential buildings, Government & public administration buildings, Commercial offices buildings, Data centers buildings, Education and K12 and universitiy buildings, Hospitals and healthcare buildings, Hotels and hospitality and leisure buildings, Exhibitions and fairs and halls buildings, Retail and stores and shops buildings, Warehouses & shopping mall buildings, Industrial buildings, Non residential buildings unspecified
Table 2. Existing situation of important energy parametres in the building stock.
Obs | Property | Residential | Public | Industrial | Other | Description |
---|---|---|---|---|---|---|
1 | Wall insulation | 17 | Default building data. excel/cyPT data collection | |||
2 | High efficient glazing | 35 | Energy performance class A in building automation/Simens pdf document searched in internet | |||
3 | Efficient lighting in baseline | 1,4 | Default building data. excel | |||
4 | Demand oriented lighting | 26,9 | Default building data. excel | |||
5 | Building Efficiency Monitoring | |||||
6 | Building Remote Monitoring | |||||
7 | Building Performance Optimization | |||||
8 | Demand controlled ventilation | 16,2or 22,4 | Default building data. excel/cyPT data collection | |||
9 | Heat and Cold Recovery in ventilation | 17,8 | ||||
10 | Efficient Motors | |||||
11 | Building Automation BACS Class C | |||||
12 | Building Automation BACS Class B | |||||
13 | Building Automation BACS Class A | |||||
14 | Room Automation HVAC | 30 | http://www.buildingtechnologies.siemens.com | |||
15 | Room Automation HVAC + lighting | |||||
16 | Building Automation HVAC + lighting + blinds | 60 | www.buildingtechnologies.siemens.com |
- Notes
- Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 1. Auxiliaries PPT. The numbers founded are not reliable but most of the high technology buildings such as isulated walls, windows.... are started to build from 10 to 15 years ago, so if we could find the building area in the year 2000, we could sustract that from the building area in Helsinki at the moment and get the building area which is built during these 10-15 years and they are high tec building areas with regard to 2 % renovation rate and rebuilding which is on going every year which sould be added to the total amount.
Energy demand
Table 3. Total energy demand by energy type and building type.
Obs | Energy type | Residential | Public | Industrial | Other | Description |
---|---|---|---|---|---|---|
1 | Electricity | |||||
2 | Cooling | |||||
3 | Heating |
- Notes
- Heating includes warm water. Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 1. Auxiliaries PPT.
Table 4. Shares of different energy sinks by building type.
Obs | Energy type | Use | Residential | Other | Admin | Industry | Description | Auxiliaries |
---|---|---|---|---|---|---|---|---|
1 | Cooling | Infiltration | 0.0 | 0.0 | 0.0 | 0.0 | PPT | |
2 | Cooling | Ventilation | 0.0 | 0.0 | 0.0 | 9.0 | PPT | |
3 | Cooling | Losses through walls through transmission | 0.0 | 0.0 | 0.0 | 0.0 | PPT | |
4 | Cooling | Heat input by solar radiation through windows | 0.0 | 0.0 | 0.0 | 0.0 | PPT | |
5 | Cooling | Losses through windows through transmission | 0.0 | 0.0 | 0.0 | 0.0 | PPT | |
6 | Cooling | Other effects (e.g. people, electrical Appliances) | 0.0 | 0.0 | 0.0 | 0.0 | PPT | |
7 | Heating | Infiltration | 0.0 | 0.0 | 0.0 | 0.0 | PPT | |
8 | Heating | Ventilation | 29.19 | 27.56 | 27.22 | 27.22 | PPT | |
9 | Heating | Walls | 34.75 | 32.81 | 32.40 | 32.40 | PPT | |
10 | Heating | Windows | 15.49 | 14.63 | 14.44 | 14.44 | PPT | |
11 | Heating | Floors | 8.74 | 8.25 | 8.15 | 8.15 | PPT | |
12 | Heating | Roofs | 9.33 | 8.81 | 8.70 | 8.70 | PPT | |
13 | Heating | Other | 0.0 | 0.0 | 0.0 | 0.0 | PPT | |
14 | Heating | Warm water | 1.89 | 0.0 | 1.76 | 1.76 | Excel | |
15 | Electricity | Lighting | 2.82 | 20.05 | 49.68 | 8.67 | Excel | |
16 | Electricity | Appliances | 24.84 | 18.74 | 14.19 | 13.00 | Excel | |
17 | Electricity | Ventilation | 0 | 12.03 | 21.29 | 18.24 | Excel | |
18 | Electricity | Other | 0.56 | 23.69 | 56.77 | 51.76 | Excel |
⇤--#: . The problem with your table is that you have changed the columns. You cannot do that, because the original classification is what we use in the model. Instead, you have to extrapolate from the existing numbers to those classes needed in the model. --Jouni (talk) 06:45, 29 April 2015 (UTC) (type: truth; paradigms: science: attack)
----#: . Use decimal points instead of decimal commas. --Jouni (talk) 06:45, 29 April 2015 (UTC) (type: truth; paradigms: science: comment)
----#: . Also include references and links so that the reader can go back to the original data and see where the numbers came from. --Jouni (talk) 06:45, 29 April 2015 (UTC) (type: truth; paradigms: science: comment)
- Notes
- Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 1. Auxiliaries: see table.
Data from Climate policies Helsinki additional data
We went through the data mentioned above and also the files given in "Climate policies Helsinki data" Climate policies Helsinki data but could not find the data for cooling, heating:infiltration, heating:other, heating:warm water:other and electricity:ventilation:resindential.
Total estimated amount of energy needed for cooling 23504480 kWh/a (whole Helsinki). Based on http://www.energiatehokashelsinki.fi/energiankulutus/Helsinki 14332 GWh/a for housing (total energy demand minus traffic 18 % [1] ) and http://www.korjaustieto.fi/pientalot/pientalojen-energiatehokkuus/energiatehokkuus-pientaloissa/pientalon-energiankulutus-ja-paastot.html 2 % of total energy demand of housing used for cooling. Total floor area of Helsinki needed (table 1).
Table 5. Changes in energy efficiency of different energy sinks.
Obs | Energy type | Use | Residential | Public | Industrial | Other | Description |
---|---|---|---|---|---|---|---|
1 | Electricity | Lighting /Lamp stock | 0.6 | 0.6 | 0.6 | 0.6 | |
2 | Electricity | Appliances | 0.6 | 0.6 | 0.6 | 0.6 | |
3 | Electricity | Ventilation | 0.6 | 0.6 | 0.6 | 0.6 | |
4 | Electricity | Other | 0.6 | 0.6 | 0.6 | 0.6 | |
5 | Cooling | Infiltration | 2 | 0.6 | 0.6 | 0.6 | |
6 | Cooling | Ventilation | 2 | 0.6 | 0.6 | 0.6 | |
7 | Cooling | Other (e.g. electric appliances, people) | 2 | 0.6 | 0.6 | 0.6 | |
8 | Heating | Infiltration | 0.6 | 0.6 | 0.6 | 0.6 | |
9 | Heating | Ventilation | 0.6 | 0.6 | 0.6 | 0.6 | |
10 | Heating | Floors | 0.6 | 0.6 | 0.6 | 0.6 | |
11 | Heating | Roofs | 0.6 | 0.6 | 0.6 | 0.6 | |
12 | Heating | Other reasons | 0.6 | 0.6 | 0.6 | 0.6 | |
13 | Heating | Warm water | 1.1 | 0.6 | 0.6 | 0.6 |
- Notes
- Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 3. Auxiliaries Excel.
Estimated 3 % of houses renovated/year and 20 % increase in energy efficiency when renovated. [2] Data apart from 0.6% values from Climate policies Helsinki additional data
The presentation about tables 4 and 5 PresentationHW9
Table 6. Important energy parameters.
Obs | Parameter | Unit | Residential | Public | Industrial | Other | Description | Auxiliary |
---|---|---|---|---|---|---|---|---|
1 | Ratio of wall area / effective area | - | 0.00 | 0.00 | 0.00 | 0.00 | PPT | |
2 | Ratio of window/effective area | - | 0.15 | 0.00 | 0.00 | 0.00 | PPT | |
3 | U-value of windows | W /m2 /K | 1.0 | 1.4 | 1.4 | 1.4 | PPT | |
4 | Solar heat gain coefficient "G-Value" of windows | % | 0,40 | 0.0 | 0.0 | 0.0 | PPT | |
5 | Efficiency increase of G-value of windows | % /a | 0.0 | 0.0 | 0.0 | 0.0 | Excel | |
6 | Efficiency increase of U-value of windows | % /a | 0.0 | 0.0 | 0.0 | 0.0 | Excel | |
7 | U-value of building walls | W /m2 /K | 0.16 | 0.25 | 0.25 | 0.28 | PPT |
- Notes
- Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 3. Auxiliaries: see table.
Economidou, M., Atanasiu, B., Despret, C., Maio, J., Nolte, I., & Rapf, O. (2011). Europe’s buildings under the microscope. A Country-by-country review of the energy performance of buildings, 131.
Unit heat consumption, opasnet
Kragh, J., Laustsen, J. B., & Svendsen, S. (2008). Proposal for Energy Rating System of windows in EU. DTU Civil Engineering-Report R-201.
http://www.ziegel.at/gbc-ziegelhandbuch/eng/ressourcen/energie/graue.htm
Lighting
Tables 7-8. Run times and shares of lamps by lamp type and building type.
Obs | Lamp | Residential | Public | Industrial | Other | Description |
---|---|---|---|---|---|---|
1 | Incandescent lamps | |||||
2 | Compact fluorescent lamps | |||||
3 | Fluorescent lamps | |||||
4 | Low voltage halogen lamps | |||||
5 | Medium voltage halogen lamps |
Obs | Lamp | Residential | Public | Industrial | Other | Description |
---|---|---|---|---|---|---|
1 | Incandescent lamps | |||||
2 | Compact fluorescent lamps | |||||
3 | Fluorescent lamps | |||||
4 | Low voltage halogen lamps | |||||
5 | Medium voltage halogen lamps |
- Notes
- Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 3. Auxiliaries Excel.
Other
Sheet 4_Input Buildings (Area Demand). Priority 1. Auxiliaries PPT. Nice to have specific factor otherwise we adapt standard data or other studies.
Data | Result |
---|---|
Number of households | |
Number of persons per household |
These tables are based on FACTA database classifications and their interpretation for assessments.
Obs | Building types in Facta | Building |
---|---|---|
1 | Ammatilliset oppilaitokset | Public |
2 | Asuntolat, vanhusten palvelutalot, asuntolahotellit | Other |
3 | Elokuvateatterit | Public |
4 | Hotellit, motellit, matkustajakodit, kylpylähotellit | Public |
5 | Kahden asunnon talot | Residential |
6 | Kasvihuoneet | Industrial |
7 | Kauppavarastot | Industrial |
8 | Kirjastot | Public |
9 | Kirkot, kappelit, luostarit, rukoushuoneet | Public |
10 | Korkeakoulurakennukset | Public |
11 | Kulkuneuvojen suoja- ja huoltorakennukset | Industrial |
12 | Lasten päiväkodit | Public |
13 | Lastenkodit, koulukodit | Residential |
14 | Liike- ja tavaratalot, kauppakeskukset | Other |
15 | Monitoimi- ja muut urheiluhallit | Other |
16 | Museot, taidegalleriat | Public |
17 | Muut erilliset pientalot | Residential |
18 | Muut kerrostalot | Residential |
19 | Muut liikenteen rakennukset | Industrial |
20 | Muut palo- ja pelastustoimen rakennukset | Other |
21 | Muut sairaalat | Other |
22 | Muut teollisuuden tuotantorakennukset | Industrial |
23 | Muut terveydenhoitorakennukset | Other |
24 | Muut urheilu- ja kuntoilurakennukset | Other |
25 | Muut uskonnollisten yhteisöjen rakennukset | Public |
26 | Muut varastorakennukset | Other |
27 | Myymälärakennukset | Other |
28 | Peruskoulut, lukiot ja muut | Public |
29 | Pysäköintitalot | Other |
30 | Rautatie- ja linja-autoasemat, lento- ja satamaterminaalit | Public |
31 | Ravintolat, ruokalat ja baarit | Public |
32 | Rivitalot | Residential |
33 | Saunarakennukset | Other |
34 | Seurakuntatalot | Public |
35 | Talousrakennukset | Other |
36 | Teollisuus- ja pienteollisuustalot | Industrial |
37 | Teollisuushallit | Industrial |
38 | Toimistorakennukset | Other |
39 | Tutkimuslaitosrakennukset | Other |
40 | Vapaa-ajan asunnot | Residential |
41 | Voimalaitosrakennukset | Industrial |
42 | Väestönsuojat | Other |
43 | Yhden asunnon talot | Residential |
44 | Muualla luokittelemattomat opetusrakennukset | Other |
45 | Muut kokoontumisrakennukset | Public |
46 | Muut rakennukset | Other |
47 | Muut sosiaalitoimen rakennukset | Public |
48 | Myymälähallit | Other |
49 | Teollisuusvarastot | Industrial |
50 | Yhdyskuntatekniikan rakennukset | Other |
51 | Järjestöjen, liittojen, työnantajien yms. opetusrakennukset | Other |
52 | Muut huoltolaitosrakennukset | Industrial |
53 | Tietoliikenteen rakennukset | Industrial |
54 | Seurain-, nuoriso- yms. talot | Public |
55 | Terveyskeskukset | Public |
56 | Vanhainkodit | Residential |
57 | Luhtitalot | Residential |
58 | Navetat, sikalat, kanalat yms. | Industrial |
59 | Muut majoitusliikerakennukset | Other |
60 | Muut majoitusrakennukset | Other |
61 | Muut maa-, metsä- ja kalatalouden rakennukset | Other |
62 | Kehitysvammaisten hoitolaitokset | Residential |
63 | Loma- lepo- ja virkistyskodit | Other |
64 | Eläinsuojat, ravihevostallit, maneesit | Other |
65 | Other | |
66 | Paloasemat | Other |
67 | Vuokrattavat lomamökit ja osakkeet (liiketoiminnallisesti) | Other |
68 | Teatterit, konsertti- ja kongressitalot, oopperat | Public |
69 | Jäähallit | Public |
70 | Keskussairaalat | Other |
71 | Näyttelyhallit | Other |
72 | Terveydenhoidon erityislaitokset (mm. kuntoutuslaitokset) | Other |
73 | Viljankuivaamot ja viljan säilytysrakennukset, siilot | Industrial |
74 | Uimahallit | Public |
75 | Vankilat | Other |
76 | Ketjutalot | Residential |
77 | Tennis-, squash- ja sulkapallohallit | Other |
Obs | Heating types in Facta | Heating |
---|---|---|
1 | Other | |
2 | Kauko- tai aluelämpö | District heating |
3 | Kevyt polttoöljy | Light oil |
4 | Kivihiili, koksi tms. | Coal |
5 | Maalämpö tms. | Geothermal |
6 | Puu | Wood |
7 | Raskas polttoöljy | Fuel oil |
8 | Sähkö | Electricity |
9 | Kaasu | Gas |
10 | Muu | Other |
Calculations
See also
- Descriptions about the summary calculations on sheet Parameter Balance (not needed any more).
- Rakennustietoruudukko pääkaupunkiseudulta [3]