Building stock in Helsinki: Difference between revisions
(→Rationale: priorities and auxiliaries added) |
|||
Line 16: | Line 16: | ||
==== Building stock ==== | ==== Building stock ==== | ||
The structures of the tables are based on CyPT Excel file N:\YMAL\Projects\ilmastotiekartta\Helsinki Data Input Template - Building Data.xlsx. | |||
Sheet 4_Input Buildings (Area Demand). Priority 1. Auxiliaries PPT. | |||
<t2b name="Effective floor area of buildings" index="Building,Year" locations="Baseline,2020,2025,2050" unit="m2" desc="Year of baseline,Type of data,Quality,Description ref etc"> | |||
Residential buildings|||||||| | |||
Government & public administration buildings|||||||| | |||
Commercial offices buildings|||||||| | |||
Data centers buildings|||||||| | |||
Education, K12 and universitiy buildings|||||||| | |||
Hospitals and healthcare buildings|||||||| | |||
Hotels, hospitality and leisure buildings|||||||| | |||
Exhibitions, fairs, halls buildings|||||||| | |||
Retail, stores and shops buildings|||||||| | |||
Warehouses & shopping mall buildings|||||||| | |||
Industrial buildings|||||||| | |||
Non residential buildings unspecified|||||||| | |||
</t2b> | |||
Absolute increase/decrease rate will be based on the inhabitants projected in time. | |||
Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 1. Auxiliaries PPT. | |||
<t2b name="Existing situation of total stock" index="Property,Building type" locations="Residential,Non-residential,Public administration" unit="%"> | <t2b name="Existing situation of total stock" index="Property,Building type" locations="Residential,Non-residential,Public administration" unit="%"> | ||
Line 36: | Line 60: | ||
</t2b> | </t2b> | ||
==== Energy demand ==== | |||
Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 1. Auxiliaries PPT. | |||
Residential | |||
<t2b name="Total energy demand by type" index="Energy type,Building type" locations="Residential,Non-residential,Public administration" unit="kWh /m2 /a"> | <t2b name="Total energy demand by type" index="Energy type,Building type" locations="Residential,Non-residential,Public administration" unit="kWh /m2 /a"> | ||
Line 64: | Line 71: | ||
Note! Heating includes warm water. | Note! Heating includes warm water. | ||
Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 3. Auxiliaries Excel. | |||
<t2b name="Efficiency increase decreasing energy demand" index="Energy type,Use,Building type" locations="Residential,Non-residential,Public administration" unit="% /a"> | <t2b name="Efficiency increase decreasing energy demand" index="Energy type,Use,Building type" locations="Residential,Non-residential,Public administration" unit="% /a"> | ||
Line 82: | Line 92: | ||
<t2b name="Share of energy demand by use type" index="Energy type,Use,Buiding type" locations="Residential,Non-residential,Public administration" unit="%"> | Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 3. Auxiliaries: see table. | ||
Cooling|Infiltration||| | |||
Cooling|Ventilation||| | <t2b name="Share of energy demand by use type" index="Energy type,Use,Buiding type" locations="Residential,Non-residential,Public administration" unit="%" desc="Auxiliaries"> | ||
Cooling|Losses through walls through transmission||| | Cooling|Infiltration||||PPT | ||
Cooling|Heat input by solar radiation through windows||| | Cooling|Ventilation||||PPT | ||
Cooling|Losses through windows through transmission||| | Cooling|Losses through walls through transmission||||PPT | ||
Cooling|Other effects (e.g. people, electrical Appliances)||| | Cooling|Heat input by solar radiation through windows||||PPT | ||
Heating|Infiltration||| | Cooling|Losses through windows through transmission||||PPT | ||
Heating|Ventilation||| | Cooling|Other effects (e.g. people, electrical Appliances)||||PPT | ||
Heating|Walls||| | Heating|Infiltration||||PPT | ||
Heating|Windows||| | Heating|Ventilation||||PPT | ||
Heating|Floors||| | Heating|Walls||||PPT | ||
Heating|Roofs||| | Heating|Windows||||PPT | ||
Heating|Other||| | Heating|Floors||||PPT | ||
Heating|Warm water||| | Heating|Roofs||||PPT | ||
Electricity|Lighting||| | Heating|Other||||PPT | ||
Electricity|Appliances||| | Heating|Warm water||||Excel | ||
Electricity|Ventilation||| | Electricity|Lighting||||Excel | ||
Electricity|Other||| | Electricity|Appliances||||Excel | ||
Electricity|Ventilation||||Excel | |||
Electricity|Other||||Excel | |||
</t2b> | </t2b> | ||
Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 3. Auxiliaries: see table. | |||
<t2b name="Energy parameters" index="Parameter,Unit,Building type" locations="Residential,Non-residential,Public administration" unit="-"> | <t2b name="Energy parameters" index="Parameter,Unit,Building type" locations="Residential,Non-residential,Public administration" unit="-" desc="Auxiliary"> | ||
Ratio of wall area / effective area|-||| | Ratio of wall area / effective area|-||||PPT | ||
Ratio of window/effective area|-||| | Ratio of window/effective area|-||||PPT | ||
U-value of windows|W /m2 /K||| | U-value of windows|W /m2 /K||||PPT | ||
Solar heat gain coefficient "G-Value" of windows|%||| | Solar heat gain coefficient "G-Value" of windows|%||||PPT | ||
Efficiency increase of G-value of windows|% /a||| | Efficiency increase of G-value of windows|% /a||||Excel | ||
Efficiency increase of U-value of windows|% /a||| | Efficiency increase of U-value of windows|% /a||||Excel | ||
U-value of building walls|W /m2 /K||| | U-value of building walls|W /m2 /K||||PPT | ||
</t2b> | </t2b> | ||
==== Lighting ==== | ==== Lighting ==== | ||
Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 3. Auxiliaries Excel. | |||
<t2b name="Average run time of lamps per year" index="Lamp,Building type" locations="Residential,Non-residential,Public administration" unit="h /a"> | <t2b name="Average run time of lamps per year" index="Lamp,Building type" locations="Residential,Non-residential,Public administration" unit="h /a"> | ||
Line 133: | Line 148: | ||
==== Other ==== | ==== Other ==== | ||
Sheet 4_Input Buildings (Area Demand). Priority 1. Auxiliaries PPT. Nice to have specific factor otherwise we adapt standard data or other studies. | |||
{| {{prettytable}} | {| {{prettytable}} | ||
Line 145: | Line 162: | ||
=== Calculations === | === Calculations === | ||
Summary graphs are made with these formulas. The rows 7-12 in the table are for | Summary graphs on sheet ''Parameter Balance'' are made with these formulas. The rows 7-12 in the table are for | ||
* General | * General | ||
* Power | * Power | ||
* Transport | * Transport | ||
* Buildings (Area) | * Buildings (Area): sheet 4_Input Buildings (Area Demand) | ||
* Buildings (Residential) | * Buildings (Residential): sheet 5_Input Residential | ||
* Buildings (Non-Residential) | * Buildings (Non-Residential): sheet 6.0_Input Non Residential | ||
* MISSING SHEET FROM SUMMARIES: 6.2_Input Public Admin | |||
The columns in the building type sheets: | The columns in the building type sheets: | ||
Line 160: | Line 178: | ||
{| {{prettytable}} | {| {{prettytable}} | ||
! Cell !! !! Priority !! !! Formula | ! Cell !! !! Priority !! Source of data !! Formula !! Explanation | ||
|---- | |---- | ||
|| B12 | || B12 | ||
|rowspan="4"| TOTALS|| all (non-optional) parameters|| ||=SUM(C12:E12) | |rowspan="4"| TOTALS|| all (non-optional) parameters|| ||=SUM(C12:E12)|| Number of parametres | ||
|---- | |---- | ||
|| C12||Prio 1|| ||=COUNTIF($'6.0_Input Non Residential'.$F$31:$F$115,1) | || C12||Prio 1|| ||=COUNTIF($'6.0_Input Non Residential'.$F$31:$F$115,1)|| Number of parametres with high priority | ||
|---- | |---- | ||
|| D12|| Prio 2 || ||=COUNTIF($'6.0_Input Non Residential'.$F$31:$F$115,2) | || D12|| Prio 2 || ||=COUNTIF($'6.0_Input Non Residential'.$F$31:$F$115,2)|| Number of parametres with medium priority | ||
|---- | |---- | ||
|| E12|| Prio 3 || ||=COUNTIF($'6.0_Input Non Residential'.$F$31:$F$115,3) | || E12|| Prio 3 || ||=COUNTIF($'6.0_Input Non Residential'.$F$31:$F$115,3)|| Number of parametres with low priority | ||
|---- | |---- | ||
|| F12 | || F12 | ||
|rowspan="6"| DONES | |rowspan="6"| DONES | ||
|rowspan="2"| Prio 1|| derived/informed|| =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="PPT")*($'6.0_Input Non Residential'.$F$31:$F$115=1)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | |rowspan="2"| Prio 1|| derived/informed|| =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="PPT")*($'6.0_Input Non Residential'.$F$31:$F$115=1)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | ||
|| Number of parametres with highest priority and auxiliary PPT | |||
|---- | |---- | ||
|| G12|| all pre-fill parameters|| =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="Excel")*($'6.0_Input Non Residential'.$F$31:$F$115=1)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | || G12|| all pre-fill parameters|| =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="Excel")*($'6.0_Input Non Residential'.$F$31:$F$115=1)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | ||
|| Number of parametres with high priority and auxiliary Excel | |||
|---- | |---- | ||
|| H12 | || H12 | ||
|rowspan="2"| Prio 2|| derived/informed|| =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="PPT")*($'6.0_Input Non Residential'.$F$31:$F$115=2)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | |rowspan="2"| Prio 2|| derived/informed|| =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="PPT")*($'6.0_Input Non Residential'.$F$31:$F$115=2)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | ||
|| Number of parametres with medium priority and auxiliary PPT | |||
|---- | |---- | ||
|| I12|| all pre-fill parameters|| =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="Excel")*($'6.0_Input Non Residential'.$F$31:$F$115=2)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | || I12|| all pre-fill parameters|| =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="Excel")*($'6.0_Input Non Residential'.$F$31:$F$115=2)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | ||
|| Number of parametres with medium priority and auxiliary Excel | |||
|---- | |---- | ||
|| J12 | || J12 | ||
|rowspan="2"| Prio 3|| derived/informed|| =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="PPT")*($'6.0_Input Non Residential'.$F$31:$F$115=3)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | |rowspan="2"| Prio 3|| derived/informed|| =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="PPT")*($'6.0_Input Non Residential'.$F$31:$F$115=3)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | ||
|| Number of parametres with low priority and auxiliary PPT | |||
|---- | |---- | ||
|| K12|| all pre-fill parameters|| =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="Excel")*($'6.0_Input Non Residential'.$F$31:$F$115=3)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | || K12|| all pre-fill parameters|| =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="Excel")*($'6.0_Input Non Residential'.$F$31:$F$115=3)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | ||
|| Number of parametres with low priority and auxiliary Excel | |||
|---- | |---- | ||
|| L12|| || || Sum of derived/informed|| =J12+H12+F12 | || L12|| || || Sum of derived/informed|| =J12+H12+F12 | ||
|| Number of parametres with auxiliary PPT | |||
|---- | |---- | ||
|| M12|| || || Sum of pre-fill|| =K12+I12+G12 | || M12|| || || Sum of pre-fill|| =K12+I12+G12 | ||
|| Number of parametres with auxiliary Excel | |||
|---- | |---- | ||
|| N12|| || || Sum of Dones|| =SUM(F12:K12) | || N12|| || || Sum of Dones|| =SUM(F12:K12) | ||
|| Number of parametres | |||
|---- | |---- | ||
|} | |} |
Revision as of 08:14, 8 April 2015
Moderator:Jouni (see all) |
|
Upload data
|
Question
What is the building stock in Helsinki?
Answer
Rationale
Data
Building stock
The structures of the tables are based on CyPT Excel file N:\YMAL\Projects\ilmastotiekartta\Helsinki Data Input Template - Building Data.xlsx.
Sheet 4_Input Buildings (Area Demand). Priority 1. Auxiliaries PPT.
Obs | Building | Baseline | 2020 | 2025 | 2050 | Year of baseline | Type of data | Quality | Description ref etc |
---|---|---|---|---|---|---|---|---|---|
1 | Residential buildings | ||||||||
2 | Government & public administration buildings | ||||||||
3 | Commercial offices buildings | ||||||||
4 | Data centers buildings | ||||||||
5 | Education, K12 and universitiy buildings | ||||||||
6 | Hospitals and healthcare buildings | ||||||||
7 | Hotels, hospitality and leisure buildings | ||||||||
8 | Exhibitions, fairs, halls buildings | ||||||||
9 | Retail, stores and shops buildings | ||||||||
10 | Warehouses & shopping mall buildings | ||||||||
11 | Industrial buildings | ||||||||
12 | Non residential buildings unspecified |
Absolute increase/decrease rate will be based on the inhabitants projected in time.
Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 1. Auxiliaries PPT.
Obs | Property | Residential | Non-residential | Public administration |
---|---|---|---|---|
1 | Wall insulation | |||
2 | High efficient glazing | |||
3 | Efficient lighting in baseline | |||
4 | Demand oriented lighting | |||
5 | Building Efficiency Monitoring | |||
6 | Building Remote Monitoring | |||
7 | Building Performance Optimization | |||
8 | Demand controlled ventilation | |||
9 | Heat and Cold Recovery in ventilation | |||
10 | Efficient Motors | |||
11 | Building Automation BACS Class C | |||
12 | Building Automation BACS Class B | |||
13 | Building Automation BACS Class A | |||
14 | Room Automation HVAC | |||
15 | Room Automation HVAC + lighting | |||
16 | Building Automation HVAC + lighting + blinds |
Energy demand
Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 1. Auxiliaries PPT.
Obs | Energy type | Residential | Non-residential | Public administration |
---|---|---|---|---|
1 | Electricity | |||
2 | Cooling | |||
3 | Heating |
Note! Heating includes warm water.
Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 3. Auxiliaries Excel.
Obs | Energy type | Use | Residential | Non-residential | Public administration |
---|---|---|---|---|---|
1 | Electricity | Lighting /Lamp stock | |||
2 | Electricity | Appliances | |||
3 | Electricity | Ventilation | |||
4 | Electricity | Other | |||
5 | Cooling | Infiltration | |||
6 | Cooling | Ventilation | |||
7 | Cooling | Other (e.g. electric appliances, people) | |||
8 | Heating | Infiltration | |||
9 | Heating | Ventilation | |||
10 | Heating | Floors | |||
11 | Heating | Roofs | |||
12 | Heating | Other reasons | |||
13 | Heating | Warm water |
Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 3. Auxiliaries: see table.
Obs | Energy type | Use | Residential | Non-residential | Public administration | Auxiliaries |
---|---|---|---|---|---|---|
1 | Cooling | Infiltration | PPT | |||
2 | Cooling | Ventilation | PPT | |||
3 | Cooling | Losses through walls through transmission | PPT | |||
4 | Cooling | Heat input by solar radiation through windows | PPT | |||
5 | Cooling | Losses through windows through transmission | PPT | |||
6 | Cooling | Other effects (e.g. people, electrical Appliances) | PPT | |||
7 | Heating | Infiltration | PPT | |||
8 | Heating | Ventilation | PPT | |||
9 | Heating | Walls | PPT | |||
10 | Heating | Windows | PPT | |||
11 | Heating | Floors | PPT | |||
12 | Heating | Roofs | PPT | |||
13 | Heating | Other | PPT | |||
14 | Heating | Warm water | Excel | |||
15 | Electricity | Lighting | Excel | |||
16 | Electricity | Appliances | Excel | |||
17 | Electricity | Ventilation | Excel | |||
18 | Electricity | Other | Excel |
Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 3. Auxiliaries: see table.
Obs | Parameter | Unit | Residential | Non-residential | Public administration | Auxiliary |
---|---|---|---|---|---|---|
1 | Ratio of wall area / effective area | - | PPT | |||
2 | Ratio of window/effective area | - | PPT | |||
3 | U-value of windows | W /m2 /K | PPT | |||
4 | Solar heat gain coefficient "G-Value" of windows | % | PPT | |||
5 | Efficiency increase of G-value of windows | % /a | Excel | |||
6 | Efficiency increase of U-value of windows | % /a | Excel | |||
7 | U-value of building walls | W /m2 /K | PPT |
Lighting
Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 3. Auxiliaries Excel.
Obs | Lamp | Residential | Non-residential | Public administration |
---|---|---|---|---|
1 | Incandescent lamps | |||
2 | Compact fluorescent lamps | |||
3 | Fluorescent lamps | |||
4 | Low voltage halogen lamps | |||
5 | Medium voltage halogen lamps |
Obs | Lamp | Residential | Non-residential | Public administration |
---|---|---|---|---|
1 | Incandescent lamps | |||
2 | Compact fluorescent lamps | |||
3 | Fluorescent lamps | |||
4 | Low voltage halogen lamps | |||
5 | Medium voltage halogen lamps |
Other
Sheet 4_Input Buildings (Area Demand). Priority 1. Auxiliaries PPT. Nice to have specific factor otherwise we adapt standard data or other studies.
Data | Result |
---|---|
Number of households | |
Number of persons per household |
Calculations
Summary graphs on sheet Parameter Balance are made with these formulas. The rows 7-12 in the table are for
- General
- Power
- Transport
- Buildings (Area): sheet 4_Input Buildings (Area Demand)
- Buildings (Residential): sheet 5_Input Residential
- Buildings (Non-Residential): sheet 6.0_Input Non Residential
- MISSING SHEET FROM SUMMARIES: 6.2_Input Public Admin
The columns in the building type sheets:
- F: Priority [1, 2, 3]
- G: Auxiliaries [Excel, PPT]
- H: Empty
Cell | Priority | Source of data | Formula | Explanation | |
---|---|---|---|---|---|
B12 | TOTALS | all (non-optional) parameters | =SUM(C12:E12) | Number of parametres | |
C12 | Prio 1 | =COUNTIF($'6.0_Input Non Residential'.$F$31:$F$115,1) | Number of parametres with high priority | ||
D12 | Prio 2 | =COUNTIF($'6.0_Input Non Residential'.$F$31:$F$115,2) | Number of parametres with medium priority | ||
E12 | Prio 3 | =COUNTIF($'6.0_Input Non Residential'.$F$31:$F$115,3) | Number of parametres with low priority | ||
F12 | DONES | Prio 1 | derived/informed | =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="PPT")*($'6.0_Input Non Residential'.$F$31:$F$115=1)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | Number of parametres with highest priority and auxiliary PPT |
G12 | all pre-fill parameters | =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="Excel")*($'6.0_Input Non Residential'.$F$31:$F$115=1)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | Number of parametres with high priority and auxiliary Excel | ||
H12 | Prio 2 | derived/informed | =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="PPT")*($'6.0_Input Non Residential'.$F$31:$F$115=2)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | Number of parametres with medium priority and auxiliary PPT | |
I12 | all pre-fill parameters | =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="Excel")*($'6.0_Input Non Residential'.$F$31:$F$115=2)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | Number of parametres with medium priority and auxiliary Excel | ||
J12 | Prio 3 | derived/informed | =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="PPT")*($'6.0_Input Non Residential'.$F$31:$F$115=3)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | Number of parametres with low priority and auxiliary PPT | |
K12 | all pre-fill parameters | =SUMPRODUCT(($'6.0_Input Non Residential'.$G$31:$G$115="Excel")*($'6.0_Input Non Residential'.$F$31:$F$115=3)*($'6.0_Input Non Residential'.$H$31:$H$115="")) | Number of parametres with low priority and auxiliary Excel | ||
L12 | Sum of derived/informed | =J12+H12+F12 | Number of parametres with auxiliary PPT | ||
M12 | Sum of pre-fill | =K12+I12+G12 | Number of parametres with auxiliary Excel | ||
N12 | Sum of Dones | =SUM(F12:K12) | Number of parametres |