Energy consumption rate shows that people are using more energy than years before or it is about the same in Finland: | |||
[[File:Capture2.PNG|400px]] | [[File:Capture2.PNG|400px]] | ||
Most of the electricity is consumed in service sectors and homes | Most of the electricity is consumed in service sectors and homes. Moreover, the electricity produced by heating is used mostly in stakeholders and a little amount in service sector: | ||
[[File:Capture3.PNG|400px]]== | [[File:Capture3.PNG|400px]]== |
Revision as of 09:13, 16 June 2015
Moderator:Marjo (see all) |
This page is a stub. You may improve it into a full page. |
Upload data
|
Question
What is the use of energy of buildings?
Answer
Energy consumption rate shows that people are using more energy than years before or it is about the same in Finland:
Most of the electricity is consumed in service sectors and homes. Moreover, the electricity produced by heating is used mostly in stakeholders and a little amount in service sector:
Wood fuel stile is the biggest source of enrgy in Finland:
The efficiency of using energy shows soaring increase in recent years:
Rationale
Baseline energy consumption
Obs | Building | Heating | Heat | User electricity | Total electricity | Year | Description |
---|---|---|---|---|---|---|---|
1 | Detached houses | District | 134.74 | 50 | 184.74 | 2010 | Calculated from energy company´s data; Pöyry |
2 | Detached houses | Electricity | 130 | 50 | 180 | 2010 | Energiapolar; Pöyry |
3 | Detached houses | Oil | 134.74 | 50 | 50 | 2010 | Pöyry. Efficiency 90-95% (energiatehokaskoti.fi). |
4 | Detached houses | Wood | 134.74 | 50 | 50 | 2010 | Assumption. Efficiency of good kettles 80%(energiatehokaskoti.fi). |
5 | Detached houses | Geothermal | 40 | 50 | 90 | 2010 | Assumption |
6 | Row houses | 168.88 | 73.5 | 73.5 | 2010 | Calculated from energy company´s data. Based on district | |
7 | Apartment houses | 172.31 | 41.7 | 41.7 | 2010 | Calculated from energy company´s data. Based on district | |
8 | Commercial | 161.82 | 229.6 | 229.6 | 2010 | Calculated from energy company´s data. Based on district | |
9 | Offices | 161.07 | 93.1 | 93.1 | 2010 | Calculated from energy company´s data. Based on district | |
10 | Health and social sector | 214.97 | 122.81 | 122.81 | 2010 | Calculated from energy company´s data. Based on district | |
11 | Public | 165.47 | 110.4 | 110.4 | 2010 | Calculated from energy company´s data. Based on district | |
12 | Sports | 121.38 | 85.9 | 85.9 | 2010 | Calculated from energy company´s data. Based on district | |
13 | Educational | 170 | 116.4 | 116.4 | 2010 | Calculated from energy company´s data. Based on district | |
14 | Industrial | 168.44 | 212.4 | 212.4 | 2010 | Calculated from energy company´s data. Based on district | |
15 | Leisure houses | 2.4 | 1 | 3.4 | 2010 | Calculated from energy company´s data. Based on electricity | |
16 | Other | 138.14 | 170.3 | 170.3 | 2010 | Calculated from energy company´s data | |
17 | Non-residential buildings | No energy source | 113 | Urgenche data for Basel | |||
18 | Non-residential buildings | Heating oil | 113 | Urgenche data for Basel | |||
19 | Non-residential buildings | Coal | 113 | Urgenche data for Basel | |||
20 | Non-residential buildings | Gas | 113 | Urgenche data for Basel | |||
21 | Non-residential buildings | Electricity | 113 | Urgenche data for Basel | |||
22 | Non-residential buildings | Wood | 113 | Urgenche data for Basel | |||
23 | Non-residential buildings | Centrifuge, hydro-extractor | 113 | Urgenche data for Basel | |||
24 | Non-residential buildings | Solar heater/ collector | 113 | Urgenche data for Basel | |||
25 | Non-residential buildings | Long-distance heating | 113 | Urgenche data for Basel | |||
26 | Non-residential buildings | Other sources | 113 | Urgenche data for Basel | |||
27 | Special constructions | 86-106 | Urgenche data for Basel (Mixed use) | ||||
28 | Single-family houses | 69 | Urgenche data for Basel | ||||
29 | Multiple-family houses | 54-106 | Urgenche data for Basel | ||||
30 | Residential buildings with subsidiary use | 86-106 | Urgenche data for Basel | ||||
31 | Buildings with partial residential use | 86-106 | Urgenche data for Basel |
Pöyry 2011. [1]
Energiapolar. [2]
Energiatehokaskoti.fi/Öljylämmitys [3]
----#: . Note that below numbers are very preliminary (esp. electricity)! --Marjo 16:49, 13 March 2013 (EET) (type: truth; paradigms: science: comment)
Obs | Building | Heating | Heat | User electricity | Year | Description |
---|---|---|---|---|---|---|
1 | Detached houses | District | 42.15 | 15.67 | 2010 | Calculated from energy company´s data; Energiapolar |
2 | Detached houses | Electricity | 40.66 | 15.67 | 2010 | Energiapolar |
3 | Detached houses | Oil | 42.15 | 15.67 | 2010 | Energiapolar |
4 | Detached houses | Wood | 42.15 | 15.67 | 2010 | Assumption |
5 | Detached houses | Geothermal | 18.56 | 15.67 | 2010 | Assumption |
6 | Row houses | District | 53.25 | 23.16 | 2010 | From energy company |
7 | Apartment houses | District | 49.2 | 11.9 | 2010 | From energy company |
8 | Commercial | District | 28.65 | 40.64 | 2010 | From energy company |
9 | Offices | District | 36.32 | 20.99 | 2010 | From energy company |
10 | Health and social sector | District | 55.2 | 31.53 | 2010 | From energy company |
11 | Public | District | 32.21 | 21.49 | 2010 | From energy company |
12 | Sports | District | 18.37 | 13 | 2010 | From energy company; Electricity value comes from city´s renovation data |
13 | Educational | District | 40.23 | 27.54 | 2010 | From energy company |
14 | Industrial | District | 30.57 | 38.55 | 2010 | From energy company |
15 | Leisure houses | Electricity | 0.68 | 0.29 | 2010 | From energy company |
16 | Other | District | 29.88 | 36.83 | 2010 | From energy company |
Energy efficiency in heating
What is the relative energy consumption of different efficiency classes compared with Old? This table tells that with some background information about heat (in kWh/m2/a), electricity, and water consumption.
Obs | Efficiency | Ratio | Heat | User electricity | Water | Description |
---|---|---|---|---|---|---|
1 | Traditional | 1.2-1.4 | 200 | Guesstimate | ||
2 | Old | 1 | 150 | 30 | Pöyry 2011 s.28 | |
3 | New | 0.4-0.5 | 70 | 50 | 40 | Pöyry 2011 s.32 (2010 SRMK) |
4 | Low-energy | 0.2-0.25 | 35 | 50 | 40 | Personal communication |
5 | Passive | 0.1-0.16 | 17.5 - 25 | 50 | 40 | Pöyry 2011 s.33; Personal communication |
Obs | Efficiency | Constructed | Fraction | Description |
---|---|---|---|---|
1 | Traditional | 1800-1944 | 100 | |
2 | Old | 1945-1994 | 100 | |
3 | New | 1995-2019 | 100 | |
4 | New | 2020-2029 | 10-20 | |
5 | Low-energy | 2020-2029 | The rest of energy class | |
6 | Passive | 2020-2029 | 25-35 | |
7 | New | 2030-2039 | 5-10 | |
8 | Low-energy | 2030-2039 | 20-50 | |
9 | Passive | 2030-2039 | The rest of energy class | |
10 | New | 2040-2064 | 0-5 | |
11 | Low-energy | 2040-2064 | 10-30 | |
12 | Passive | 2040-2064 | The rest of energy class |
- Old: old buildings to be renovated (or in need of renovation)
- New: normal new buildings (no current need of renovation)
- Low-energy: buildings consuming about half of the energy of a new building
- Passive: buildings consuming a quarter or less of the energy of a new building
- Chinese green building system: [4] [5]
Impact of renovations
Obs | Renovation | Relative | Absolute | Renovation details | Description |
---|---|---|---|---|---|
1 | Windows | 0.85 | 25 | New windows and doors | Pöyry 2011 |
2 | Technical systems | 0.50 | 75 | New windows, sealing of building's sheath, improvement of building's technical systems | Pöyry 2011 |
3 | Sheath reform | 0.35 | 100 | New windows, sealing of building's sheath, improvement of building's technical systems, significant reform of building's sheath | Pöyry 2011 |
4 | General | 0.85 | - | General renovation | Pöyry 2011 |
5 | None | 1 | 0 | Renovation not done |
Regulations regarding energy consumption of buildings
Obs | Building | Year | E-value | Description |
---|---|---|---|---|
1 | Detached houses | 2012 forward | 204 | Heated net area <120 m2; Finland´s Environmental Administration |
2 | Row houses | 2012 forward | 150 | Finland´s Environmental Administration |
3 | Apartment houses | 2012 forward | 130 | Finland´s Environmental Administration |
4 | Shops and other commercial buildings | 2012 forward | 240 | Finland´s Environmental Administration |
5 | Offices | 2012 forward | 170 | Finland´s Environmental Administration |
6 | Health and social sector: Hospitals | 2012 forward | 450 | Finland´s Environmental Administration |
7 | Health and social sector: Health care centers etc. | 2012 forward | 170 | Finland´s Environmental Administration |
8 | Public | 2012 forward | 240 | Finland´s Environmental Administration |
9 | Sports | 2012 forward | 170 | Does not apply to swimming- and ice halls; Finland´s Environmental Administration |
10 | Educational | 2012 forward | 170 | Finland´s Environmental Administration |
11 | Industrial | 2012 forward | - | E-value must be calculated but there´s no limit for it; Finland´s Environmental Administration |
12 | Leisure buildings | 2012 forward | - | E-value must be calculated but there´s no limit for it; Finland´s Environmental Administration |
13 | Other | 2012 forward | - | E-value must be calculated but there´s no limit for it; Finland´s Environmental Administration |