Energy use of buildings: Difference between revisions
Jump to navigation
Jump to search
(ovariable energyUse updated) |
|||
Line 126: | Line 126: | ||
===Calculations for ovariables=== | ===Calculations for ovariables=== | ||
<rcode name='initiate' embed= | <rcode name='initiate' embed=0 label='Initiate objects'> | ||
library(OpasnetUtils) | library(OpasnetUtils) | ||
Line 137: | Line 137: | ||
levels(energyUse@data$Heating)[levels(energyUse@data$Heating) == ""] <- NA | levels(energyUse@data$Heating)[levels(energyUse@data$Heating) == ""] <- NA | ||
energyUse@data <- fillna(energyUse@data, "Heating") | energyUse@data <- fillna(energyUse@data, "Heating") | ||
energyUse@data <- energyUse@data[ | |||
energyUse@data[["Energy use"]] == "Heat" , | |||
colnames(energyUse@data) != "Energy use" | |||
] | |||
energy.per.volume <- Ovariable( | energy.per.volume <- Ovariable( | ||
Line 148: | Line 152: | ||
ddata = 'Op_en5488', | ddata = 'Op_en5488', | ||
subset = 'Energy efficiency of new buildings in the future' | subset = 'Energy efficiency of new buildings in the future' | ||
) | |||
efficienciesNew@data$Efficiency <- factor( | |||
efficienciesNew@data$Efficiency, | |||
levels = c("Old", "New", "Low-energy", "Passive"), | |||
ordered = TRUE | |||
) | ) | ||
Line 160: | Line 169: | ||
ddata = 'Op_en5488', | ddata = 'Op_en5488', | ||
subset = 'Energy saving potential of different renovations' | subset = 'Energy saving potential of different renovations' | ||
) | |||
savingPotential@data <- savingPotential@data[ | |||
savingPotential@data$Observation == "Relative" , | |||
colnames(savingPotential@data) != "Observation" | |||
] | |||
savingPotential@data$Renovation <- factor( | |||
savingPotential@data$Renovation, | |||
levels = c("None", "General", "Windows", "Technical systems", "Sheath reform"), | |||
ordered = TRUE | |||
) | ) | ||
levels(savingPotential@data$Building2)[levels(savingPotential@data$Building2) == ""] <- NA | levels(savingPotential@data$Building2)[levels(savingPotential@data$Building2) == ""] <- NA | ||
savingPotential@data <- fillna(savingPotential@data, "Building2") | |||
savingPotential@data$savingPotentialResult <- 1 - as.numeric(as.character(savingPotential@data$savingPotentialResult)) / 100 | |||
energy.classes.of.buildings <- Ovariable( | energy.classes.of.buildings <- Ovariable( |
Revision as of 18:03, 12 February 2015
Moderator:Marjo (see all) |
This page is a stub. You may improve it into a full page. |
Upload data
|
Question
What is the use of energy of buildings?
Answer
Rationale
Baseline energy consumption
Obs | Building | Heating | Heat | User electricity | Total electricity | Year | Description |
---|---|---|---|---|---|---|---|
1 | Detached houses | District | 134.74 | 50 | 184.74 | 2010 | Calculated from energy company´s data; Pöyry |
2 | Detached houses | Electricity | 130 | 50 | 180 | 2010 | Energiapolar; Pöyry |
3 | Detached houses | Oil | 134.74 | 50 | 50 | 2010 | Pöyry. Efficiency 90-95% (energiatehokaskoti.fi). |
4 | Detached houses | Wood | 134.74 | 50 | 50 | 2010 | Assumption. Efficiency of good kettles 80%(energiatehokaskoti.fi). |
5 | Detached houses | Geothermal | 40 | 50 | 90 | 2010 | Assumption |
6 | Row houses | 168.88 | 73.5 | 73.5 | 2010 | Calculated from energy company´s data. Based on district | |
7 | Apartment houses | 172.31 | 41.7 | 41.7 | 2010 | Calculated from energy company´s data. Based on district | |
8 | Commercial | 161.82 | 229.6 | 229.6 | 2010 | Calculated from energy company´s data. Based on district | |
9 | Offices | 161.07 | 93.1 | 93.1 | 2010 | Calculated from energy company´s data. Based on district | |
10 | Health and social sector | 214.97 | 122.81 | 122.81 | 2010 | Calculated from energy company´s data. Based on district | |
11 | Public | 165.47 | 110.4 | 110.4 | 2010 | Calculated from energy company´s data. Based on district | |
12 | Sports | 121.38 | 85.9 | 85.9 | 2010 | Calculated from energy company´s data. Based on district | |
13 | Educational | 170 | 116.4 | 116.4 | 2010 | Calculated from energy company´s data. Based on district | |
14 | Industrial | 168.44 | 212.4 | 212.4 | 2010 | Calculated from energy company´s data. Based on district | |
15 | Leisure houses | 2.4 | 1 | 3.4 | 2010 | Calculated from energy company´s data. Based on electricity | |
16 | Other | 138.14 | 170.3 | 170.3 | 2010 | Calculated from energy company´s data | |
17 | Non-residential buildings | 150 | 50 | Guesstimate for Basel | |||
18 | Special constructions | 150 | 50 | Guesstimate for Basel | |||
19 | Single-family houses | 150 | 50 | Guesstimate for Basel | |||
20 | Multiple-family houses | 150 | 50 | Guesstimate for Basel | |||
21 | Residential buildings with subsidiary use | 150 | 50 | Guesstimate for Basel | |||
22 | Buildings with partial residential use | 150 | 50 | Guesstimate for Basel |
Pöyry 2011. [1]
Energiapolar. [2]
Energiatehokaskoti.fi/Öljylämmitys [3]
----#: . Note that below numbers are very preliminary (esp. electricity)! --Marjo 16:49, 13 March 2013 (EET) (type: truth; paradigms: science: comment)
Obs | Building | Heating | Heat | User electricity | Year | Description |
---|---|---|---|---|---|---|
1 | Detached houses | District | 42.15 | 15.67 | 2010 | Calculated from energy company´s data; Energiapolar |
2 | Detached houses | Electricity | 40.66 | 15.67 | 2010 | Energiapolar |
3 | Detached houses | Oil | 42.15 | 15.67 | 2010 | Energiapolar |
4 | Detached houses | Wood | 42.15 | 15.67 | 2010 | Assumption |
5 | Detached houses | Geothermal | 18.56 | 15.67 | 2010 | Assumption |
6 | Row houses | District | 53.25 | 23.16 | 2010 | From energy company |
7 | Apartment houses | District | 49.2 | 11.9 | 2010 | From energy company |
8 | Commercial | District | 28.65 | 40.64 | 2010 | From energy company |
9 | Offices | District | 36.32 | 20.99 | 2010 | From energy company |
10 | Health and social sector | District | 55.2 | 31.53 | 2010 | From energy company |
11 | Public | District | 32.21 | 21.49 | 2010 | From energy company |
12 | Sports | District | 18.37 | 13 | 2010 | From energy company; Electricity value comes from city´s renovation data |
13 | Educational | District | 40.23 | 27.54 | 2010 | From energy company |
14 | Industrial | District | 30.57 | 38.55 | 2010 | From energy company |
15 | Leisure houses | Electricity | 0.68 | 0.29 | 2010 | From energy company |
16 | Other | District | 29.88 | 36.83 | 2010 | From energy company |
Energy efficiency in heating
Obs | Efficiency | Heat | User electricity | Water | Description |
---|---|---|---|---|---|
1 | Old | 150 | 30 | Pöyry 2011 s.28 | |
2 | New | 70 | 50 | 40 | Pöyry 2011 s.32 (2010 SRMK) |
3 | Low-energy | 35 | 50 | 40 | Personal communication |
4 | Passive | 17.5 - 25 | 50 | 40 | Pöyry 2011 s.33; Personal communication |
Obs | Efficiency | Constructed | Fraction | Description |
---|---|---|---|---|
1 | New | 2020-2029 | 10-20 | |
2 | Low-energy | 2020-2029 | The rest of energy class | |
3 | Passive | 2020-2029 | 25-35 | |
4 | New | 2030-2039 | 5-10 | |
5 | Low-energy | 2030-2039 | 20-50 | |
6 | Passive | 2030-2039 | The rest of energy class | |
7 | New | 2040-2049 | 0-5 | |
8 | Low-energy | 2040-2049 | 10-30 | |
9 | Passive | 2040-2049 | The rest of energy class |
- Old: old buildings to be renovated (or in need of renovation)
- New: normal new buildings (no current need of renovation)
- Low-energy: buildings consuming about half of the energy of a new building
- Passive: buildings consuming a quarter or less of the energy of a new building
- Chinese green building system: [4] [5]
Impact of renovations
Obs | Efficiency | Building2 | Renovation | Relative | Absolute | Renovation details | Description |
---|---|---|---|---|---|---|---|
1 | Old | Residential | Windows | 15 | 25 | New windows and doors | Pöyry 2011 |
2 | Old | Residential | Technical systems | 50 | 75 | New windows, sealing of building's sheath, improvement of building's technical systems | Pöyry 2011 |
3 | Old | Residential | Sheath reform | 65 | 100 | New windows, sealing of building's sheath, improvement of building's technical systems, significant reform of building's sheath | Pöyry 2011 |
4 | Old | Non-residential | General | 15 | - | General renovation | Pöyry 2011 |
5 | Old | None | 0 | 0 | Renovation not done | ||
6 | New | None | 0 | 0 | Renovation not done | ||
7 | Low-energy | None | 0 | 0 | Renovation not done | ||
8 | Passive | None | 0 | 0 | Renovation not done |
Regulations regarding energy consumption of buildings
Obs | Building | Year | E-value | Description |
---|---|---|---|---|
1 | Detached houses | 2012 forward | 204 | Heated net area <120 m2; Finland´s Environmental Administration |
2 | Row houses | 2012 forward | 150 | Finland´s Environmental Administration |
3 | Apartment houses | 2012 forward | 130 | Finland´s Environmental Administration |
4 | Shops and other commercial buildings | 2012 forward | 240 | Finland´s Environmental Administration |
5 | Offices | 2012 forward | 170 | Finland´s Environmental Administration |
6 | Health and social sector: Hospitals | 2012 forward | 450 | Finland´s Environmental Administration |
7 | Health and social sector: Health care centers etc. | 2012 forward | 170 | Finland´s Environmental Administration |
8 | Public | 2012 forward | 240 | Finland´s Environmental Administration |
9 | Sports | 2012 forward | 170 | Does not apply to swimming- and ice halls; Finland´s Environmental Administration |
10 | Educational | 2012 forward | 170 | Finland´s Environmental Administration |
11 | Industrial | 2012 forward | - | E-value must be calculated but there´s no limit for it; Finland´s Environmental Administration |
12 | Leisure buildings | 2012 forward | - | E-value must be calculated but there´s no limit for it; Finland´s Environmental Administration |
13 | Other | 2012 forward | - | E-value must be calculated but there´s no limit for it; Finland´s Environmental Administration |