Intake fractions of PM: Difference between revisions

From Opasnet
Jump to navigation Jump to search
(codes fixed)
Line 49: Line 49:


==References==
==References==
* [https://www.julkari.fi/handle/10024/79939 PILTTI final report]


<references/>
<references/>

Revision as of 08:56, 16 February 2014



Question

What are intake fractions of airborne particulate matter for different emission sources and locations?

Answer

+ Show code

Rationale

Intake fractions of PM: Difference between revisions(per million)
ObsGeographical areaYearPM typeSource categorySubcategoryResultDescription of sub-categorySpecificationDescription
1Finland2000Anthropogenic PM2.5Power plantsLarge power plants0.18-0.37Emission from large (>50 MW) power plants (n=117)mode; min-maxTainio et al. (2010): 0.28 (0.18-0.37)
2Finland2000Anthropogenic PM2.5Power plantsSmall power plants0.27-0.44Emission from small (<50 MW) power plants mode; min-maxTainio et al. (2010): 0.34 (0.27-0.44)
3Northern Europe-Anthropogenic PM2.5Power plantsMajor power plants0.50-mean of all seasonsTainio et al. (2009)

Calculations

+ Show code


See also

Keywords

References


Related files