Hämeenkyrö MSWI risk assessment: Dioxin: Difference between revisions

From Opasnet
Jump to navigation Jump to search
No edit summary
Line 24: Line 24:




====Emission factors for different processes (UNEP 1999a)====


=====Municipal solid waste incineration (µg TEQ/t MSW burned)=====
Emission factors for different processes (UNEP 1999a)
 
 
Municipal solid waste incineration (µg TEQ/t MSW burned)


:Low technology combustion, no APC system: air 3500, fly ash 0, bottom ash 75
:Low technology combustion, no APC system: air 3500, fly ash 0, bottom ash 75
Line 37: Line 39:




=====Energy production (µg TEQ/TJ)=====
Energy production (µg TEQ/TJ)


:Natural gas fired power boiler: 0.5
:Natural gas fired power boiler: 0.5
Line 58: Line 60:




=====Transport (µg TEQ/t of fuel burned)=====
Transport (µg TEQ/t of fuel burned)


:4-stroke engines  
:4-stroke engines  
Line 71: Line 73:




=====Production of pulp and paper products=====
Production of pulp and paper products




=====Emissions from landfills (pg TEQ/L of leachate released)=====
Emissions from landfills (pg TEQ/L of leachate released)


:Hazardous wastes: air 0, water 200
:Hazardous wastes: air 0, water 200

Revision as of 11:05, 22 September 2006

See the main page of this assessment: Hämeenkyrö MSWI risk assessment: General

Dioxin emissions in Hämeenkyrö

Virpi

Intake fraction for dioxin emissions from Hämeenkyrö

Baseline dioxin exposure in Hämeenkyrö

Marjo

Dioxin exposure due to MSWI in Hämeenkyrö

Martin


Health effects caused by dioxin exposure

Sanna